CVE-2025-34050 (GCVE-0-2025-34050)
Vulnerability from cvelistv5 – Published: 2025-07-01 14:42 – Updated: 2025-07-01 18:45
VLAI?
Title
AVTECH IP Camera, DVR, and NVR Devices Cross-Site Request Forgery
Summary
A cross-site request forgery (CSRF) vulnerability exists in the web interface of AVTECH IP camera, DVR, and NVR devices. An attacker can craft malicious requests that, when executed in the context of an authenticated user’s browser session, allow unauthorized changes to the device configuration without user interaction.
Severity ?
CWE
- CWE-352 - Cross-Site Request Forgery (CSRF)
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
| Vendor | Product | Version | ||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| AVTECH | IP cameras |
Affected:
0
|
||||||||||||
|
||||||||||||||
Credits
Gergely Eberhardt (SEARCH-LAB.hu)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-34050",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-07-01T18:44:55.395830Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-07-01T18:45:06.703Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"Web Management Interface (configuration endpoints)"
],
"product": "IP cameras",
"vendor": "AVTECH",
"versions": [
{
"status": "affected",
"version": "0"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web Management Interface (configuration endpoints)"
],
"product": "DVR devices",
"vendor": "AVTECH",
"versions": [
{
"status": "affected",
"version": "0"
}
]
},
{
"defaultStatus": "unaffected",
"modules": [
"Web Management Interface (configuration endpoints)"
],
"product": "NVR devices",
"vendor": "AVTECH",
"versions": [
{
"status": "affected",
"version": "0"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Gergely Eberhardt (SEARCH-LAB.hu)"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "A\u0026nbsp;cross-site request forgery (CSRF) vulnerability exists in the web interface of AVTECH IP camera, DVR, and NVR devices. An attacker can craft malicious requests that, when executed in the context of an authenticated user\u2019s browser session, allow unauthorized changes to the device configuration without user interaction."
}
],
"value": "A\u00a0cross-site request forgery (CSRF) vulnerability exists in the web interface of AVTECH IP camera, DVR, and NVR devices. An attacker can craft malicious requests that, when executed in the context of an authenticated user\u2019s browser session, allow unauthorized changes to the device configuration without user interaction."
}
],
"impacts": [
{
"capecId": "CAPEC-62",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-62 Cross Site Request Forgery"
}
]
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 5.1,
"baseSeverity": "MEDIUM",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "ACTIVE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N",
"version": "4.0",
"vulnAvailabilityImpact": "NONE",
"vulnConfidentialityImpact": "NONE",
"vulnIntegrityImpact": "LOW",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-352",
"description": "CWE-352 Cross-Site Request Forgery (CSRF)",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-07-01T14:42:57.143Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://www.exploit-db.com/exploits/40500"
},
{
"tags": [
"product"
],
"url": "https://avtech.com/"
},
{
"tags": [
"third-party-advisory",
"technical-description"
],
"url": "https://web.archive.org/web/20240810225729/https://www.search-lab.hu/advisories/126-AVTech-devices-multiple-vulnerabilities"
},
{
"tags": [
"exploit"
],
"url": "https://web.archive.org/web/20161029201749/https://github.com/ebux/AVTECH"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://vulncheck.com/advisories/avtech-ipcamera-nvr-dvr-mulitple-vulns"
}
],
"source": {
"discovery": "UNKNOWN"
},
"title": "AVTECH IP Camera, DVR, and NVR Devices Cross-Site Request Forgery",
"x_generator": {
"engine": "Vulnogram 0.2.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2025-34050",
"datePublished": "2025-07-01T14:42:57.143Z",
"dateReserved": "2025-04-15T19:15:22.548Z",
"dateUpdated": "2025-07-01T18:45:06.703Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-34050\",\"sourceIdentifier\":\"disclosure@vulncheck.com\",\"published\":\"2025-07-01T15:15:22.933\",\"lastModified\":\"2025-07-03T15:14:12.767\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A\u00a0cross-site request forgery (CSRF) vulnerability exists in the web interface of AVTECH IP camera, DVR, and NVR devices. An attacker can craft malicious requests that, when executed in the context of an authenticated user\u2019s browser session, allow unauthorized changes to the device configuration without user interaction.\"},{\"lang\":\"es\",\"value\":\"Existe una vulnerabilidad de cross-site request forgery (CSRF) en la interfaz web de AVTECH IP camera, DVR, y NVR. Un atacante puede manipular solicitudes maliciosas que, al ejecutarse en el contexto de la sesi\u00f3n del navegador de un usuario autenticado, permiten cambios no autorizados en la configuraci\u00f3n del dispositivo sin la interacci\u00f3n del usuario.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"disclosure@vulncheck.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":5.1,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"ACTIVE\",\"vulnConfidentialityImpact\":\"NONE\",\"vulnIntegrityImpact\":\"LOW\",\"vulnAvailabilityImpact\":\"NONE\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}]},\"weaknesses\":[{\"source\":\"disclosure@vulncheck.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-352\"}]}],\"references\":[{\"url\":\"https://avtech.com/\",\"source\":\"disclosure@vulncheck.com\"},{\"url\":\"https://vulncheck.com/advisories/avtech-ipcamera-nvr-dvr-mulitple-vulns\",\"source\":\"disclosure@vulncheck.com\"},{\"url\":\"https://web.archive.org/web/20161029201749/https://github.com/ebux/AVTECH\",\"source\":\"disclosure@vulncheck.com\"},{\"url\":\"https://web.archive.org/web/20240810225729/https://www.search-lab.hu/advisories/126-AVTech-devices-multiple-vulnerabilities\",\"source\":\"disclosure@vulncheck.com\"},{\"url\":\"https://www.exploit-db.com/exploits/40500\",\"source\":\"disclosure@vulncheck.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-34050\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-07-01T18:44:55.395830Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-07-01T18:29:18.916Z\"}}], \"cna\": {\"title\": \"AVTECH IP Camera, DVR, and NVR Devices Cross-Site Request Forgery\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Gergely Eberhardt (SEARCH-LAB.hu)\"}], \"impacts\": [{\"capecId\": \"CAPEC-62\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-62 Cross Site Request Forgery\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 5.1, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"MEDIUM\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:A/VC:N/VI:L/VA:N/SC:N/SI:N/SA:N\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"ACTIVE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"LOW\", \"subAvailabilityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"NONE\", \"subConfidentialityImpact\": \"NONE\", \"vulnConfidentialityImpact\": \"NONE\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"AVTECH\", \"modules\": [\"Web Management Interface (configuration endpoints)\"], \"product\": \"IP cameras\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"AVTECH\", \"modules\": [\"Web Management Interface (configuration endpoints)\"], \"product\": \"DVR devices\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\"}], \"defaultStatus\": \"unaffected\"}, {\"vendor\": \"AVTECH\", \"modules\": [\"Web Management Interface (configuration endpoints)\"], \"product\": \"NVR devices\", \"versions\": [{\"status\": \"affected\", \"version\": \"0\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.exploit-db.com/exploits/40500\", \"tags\": [\"exploit\"]}, {\"url\": \"https://avtech.com/\", \"tags\": [\"product\"]}, {\"url\": \"https://web.archive.org/web/20240810225729/https://www.search-lab.hu/advisories/126-AVTech-devices-multiple-vulnerabilities\", \"tags\": [\"third-party-advisory\", \"technical-description\"]}, {\"url\": \"https://web.archive.org/web/20161029201749/https://github.com/ebux/AVTECH\", \"tags\": [\"exploit\"]}, {\"url\": \"https://vulncheck.com/advisories/avtech-ipcamera-nvr-dvr-mulitple-vulns\", \"tags\": [\"third-party-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A\\u00a0cross-site request forgery (CSRF) vulnerability exists in the web interface of AVTECH IP camera, DVR, and NVR devices. An attacker can craft malicious requests that, when executed in the context of an authenticated user\\u2019s browser session, allow unauthorized changes to the device configuration without user interaction.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"A\u0026nbsp;cross-site request forgery (CSRF) vulnerability exists in the web interface of AVTECH IP camera, DVR, and NVR devices. An attacker can craft malicious requests that, when executed in the context of an authenticated user\\u2019s browser session, allow unauthorized changes to the device configuration without user interaction.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-352\", \"description\": \"CWE-352 Cross-Site Request Forgery (CSRF)\"}]}], \"providerMetadata\": {\"orgId\": \"83251b91-4cc7-4094-a5c7-464a1b83ea10\", \"shortName\": \"VulnCheck\", \"dateUpdated\": \"2025-07-01T14:42:57.143Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-34050\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-07-01T18:45:06.703Z\", \"dateReserved\": \"2025-04-15T19:15:22.548Z\", \"assignerOrgId\": \"83251b91-4cc7-4094-a5c7-464a1b83ea10\", \"datePublished\": \"2025-07-01T14:42:57.143Z\", \"assignerShortName\": \"VulnCheck\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…