CVE-2025-5443 (GCVE-0-2025-5443)
Vulnerability from cvelistv5 – Published: 2025-06-02 11:31 – Updated: 2025-06-02 16:29
VLAI?
Title
Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 wirelessAdvancedHidden os command injection
Summary
A vulnerability, which was classified as critical, was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected is the function wirelessAdvancedHidden of the file /goform/wirelessAdvancedHidden. The manipulation of the argument ExtChSelector/24GSelector/5GSelector leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.
Severity ?
6.3 (Medium)
6.3 (Medium)
Assigner
References
| URL | Tags | ||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||||||||
Impacted products
| Vendor | Product | Version | |||||||||||||||||||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| Linksys | RE6500 |
Affected:
1.0.013.001
Affected: 1.0.04.001 Affected: 1.0.04.002 Affected: 1.1.05.003 Affected: 1.2.07.001 |
|||||||||||||||||||||||||||
|
|||||||||||||||||||||||||||||
Credits
pjqwudi (VulDB User)
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-5443",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-06-02T16:28:56.375367Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-06-02T16:29:14.101Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_6/6.md"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "RE6500",
"vendor": "Linksys",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
},
{
"product": "RE6250",
"vendor": "Linksys",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
},
{
"product": "RE6300",
"vendor": "Linksys",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
},
{
"product": "RE6350",
"vendor": "Linksys",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
},
{
"product": "RE7000",
"vendor": "Linksys",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
},
{
"product": "RE9000",
"vendor": "Linksys",
"versions": [
{
"status": "affected",
"version": "1.0.013.001"
},
{
"status": "affected",
"version": "1.0.04.001"
},
{
"status": "affected",
"version": "1.0.04.002"
},
{
"status": "affected",
"version": "1.1.05.003"
},
{
"status": "affected",
"version": "1.2.07.001"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "reporter",
"value": "pjqwudi (VulDB User)"
}
],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability, which was classified as critical, was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected is the function wirelessAdvancedHidden of the file /goform/wirelessAdvancedHidden. The manipulation of the argument ExtChSelector/24GSelector/5GSelector leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "de",
"value": "Es wurde eine Schwachstelle in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 gefunden. Sie wurde als kritisch eingestuft. Es geht dabei um die Funktion wirelessAdvancedHidden der Datei /goform/wirelessAdvancedHidden. Durch Beeinflussen des Arguments ExtChSelector/24GSelector/5GSelector mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \u00fcber das Netzwerk passieren. Der Exploit steht zur \u00f6ffentlichen Verf\u00fcgung."
}
],
"metrics": [
{
"cvssV4_0": {
"baseScore": 5.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N",
"version": "4.0"
}
},
{
"cvssV3_1": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
}
},
{
"cvssV3_0": {
"baseScore": 6.3,
"baseSeverity": "MEDIUM",
"vectorString": "CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L",
"version": "3.0"
}
},
{
"cvssV2_0": {
"baseScore": 6.5,
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-78",
"description": "OS Command Injection",
"lang": "en",
"type": "CWE"
}
]
},
{
"descriptions": [
{
"cweId": "CWE-77",
"description": "Command Injection",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-06-02T11:31:04.438Z",
"orgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"shortName": "VulDB"
},
"references": [
{
"name": "VDB-310782 | Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 wirelessAdvancedHidden os command injection",
"tags": [
"vdb-entry",
"technical-description"
],
"url": "https://vuldb.com/?id.310782"
},
{
"name": "VDB-310782 | CTI Indicators (IOB, IOC, TTP, IOA)",
"tags": [
"signature",
"permissions-required"
],
"url": "https://vuldb.com/?ctiid.310782"
},
{
"name": "Submit #584365 | Linksys RE6500\u3001RE6250\u3001RE6300\u3001RE6350\u3001RE7000\u3001RE9000 RE6500(1.0.013.001) RE6250(1.0.04.001) RE6300(1.2.07.001) RE6350(1.0.04.001) RE7000(1.1.05.003) RE9000(1.0.04.002) OS Command Injection",
"tags": [
"third-party-advisory"
],
"url": "https://vuldb.com/?submit.584365"
},
{
"tags": [
"exploit"
],
"url": "https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_6/6.md"
},
{
"tags": [
"product"
],
"url": "https://www.linksys.com/"
}
],
"timeline": [
{
"lang": "en",
"time": "2025-06-01T00:00:00.000Z",
"value": "Advisory disclosed"
},
{
"lang": "en",
"time": "2025-06-01T02:00:00.000Z",
"value": "VulDB entry created"
},
{
"lang": "en",
"time": "2025-06-01T19:11:51.000Z",
"value": "VulDB entry last update"
}
],
"title": "Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 wirelessAdvancedHidden os command injection"
}
},
"cveMetadata": {
"assignerOrgId": "1af790b2-7ee1-4545-860a-a788eba489b5",
"assignerShortName": "VulDB",
"cveId": "CVE-2025-5443",
"datePublished": "2025-06-02T11:31:04.438Z",
"dateReserved": "2025-06-01T17:06:27.764Z",
"dateUpdated": "2025-06-02T16:29:14.101Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-5443\",\"sourceIdentifier\":\"cna@vuldb.com\",\"published\":\"2025-06-02T12:15:26.143\",\"lastModified\":\"2025-06-10T15:14:40.057\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability, which was classified as critical, was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected is the function wirelessAdvancedHidden of the file /goform/wirelessAdvancedHidden. The manipulation of the argument ExtChSelector/24GSelector/5GSelector leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.\"},{\"lang\":\"es\",\"value\":\"Se encontr\u00f3 una vulnerabilidad clasificada como cr\u00edtica en los Linksys RE6500, RE6250, RE6300, RE6350, RE7000 y RE9000 (versi\u00f3n 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001). La funci\u00f3n wirelessAdvancedHidden del archivo /goform/wirelessAdvancedHidden se ve afectada. La manipulaci\u00f3n del argumento ExtChSelector/24GSelector/5GSelector provoca la inyecci\u00f3n de comandos del sistema operativo. Es posible ejecutar el ataque de forma remota. Se ha hecho p\u00fablico el exploit y puede que sea utilizado. Se contact\u00f3 al proveedor con antelaci\u00f3n para informarle sobre esta divulgaci\u00f3n, pero no respondi\u00f3.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":5.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"LOW\",\"vulnIntegrityImpact\":\"LOW\",\"vulnAvailabilityImpact\":\"LOW\",\"subConfidentialityImpact\":\"NONE\",\"subIntegrityImpact\":\"NONE\",\"subAvailabilityImpact\":\"NONE\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}],\"cvssMetricV31\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\",\"baseScore\":6.3,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"LOW\",\"availabilityImpact\":\"LOW\"},\"exploitabilityScore\":2.8,\"impactScore\":3.4},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":9.8,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":3.9,\"impactScore\":5.9}],\"cvssMetricV2\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"2.0\",\"vectorString\":\"AV:N/AC:L/Au:S/C:P/I:P/A:P\",\"baseScore\":6.5,\"accessVector\":\"NETWORK\",\"accessComplexity\":\"LOW\",\"authentication\":\"SINGLE\",\"confidentialityImpact\":\"PARTIAL\",\"integrityImpact\":\"PARTIAL\",\"availabilityImpact\":\"PARTIAL\"},\"baseSeverity\":\"MEDIUM\",\"exploitabilityScore\":8.0,\"impactScore\":6.4,\"acInsufInfo\":false,\"obtainAllPrivilege\":false,\"obtainUserPrivilege\":false,\"obtainOtherPrivilege\":false,\"userInteractionRequired\":false}]},\"weaknesses\":[{\"source\":\"cna@vuldb.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-77\"},{\"lang\":\"en\",\"value\":\"CWE-78\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-78\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re9000_firmware:1.0.04.002:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"11F24125-412F-473A-BF34-02284F8DAC2D\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re9000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7424D2C2-BCF4-4B2D-BE59-71B50B13FE77\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re6250_firmware:1.0.04.001:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"70728D67-153A-49FA-80E2-0DE9086DA253\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re6250:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"898FD49F-4225-47FF-822C-9E4FFB5EE192\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re6300_firmware:1.2.07.001:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1E3A6A93-D598-4F52-808C-EAA45B468066\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re6300:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"25647318-6422-418C-99B8-C806FF490028\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re6350_firmware:1.0.04.001:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"0E0A8CCC-BD94-4865-9C0C-B60BD375CDC8\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re6350:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"4FFD3F65-E520-415D-BAB8-57FACEA5BEC7\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re7000_firmware:1.1.05.003:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"8DC2325A-068F-4B5E-A365-6BF1103E320E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re7000:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"D04E83B6-EE99-42EB-AA37-895B1467CEDA\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:linksys:re6500_firmware:1.0.013.001:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"92354C9C-D1B2-4143-803D-DE5EF7842184\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:linksys:re6500:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"52622B22-2E42-443B-81DA-7C42ECCF0564\"}]}]}],\"references\":[{\"url\":\"https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_6/6.md\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://vuldb.com/?ctiid.310782\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Permissions Required\"]},{\"url\":\"https://vuldb.com/?id.310782\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://vuldb.com/?submit.584365\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Third Party Advisory\",\"VDB Entry\"]},{\"url\":\"https://www.linksys.com/\",\"source\":\"cna@vuldb.com\",\"tags\":[\"Product\"]},{\"url\":\"https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_6/6.md\",\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-5443\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-06-02T16:28:56.375367Z\"}}}], \"references\": [{\"url\": \"https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_6/6.md\", \"tags\": [\"exploit\"]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-06-02T16:29:08.257Z\"}}], \"cna\": {\"title\": \"Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 wirelessAdvancedHidden os command injection\", \"credits\": [{\"lang\": \"en\", \"type\": \"reporter\", \"value\": \"pjqwudi (VulDB User)\"}], \"metrics\": [{\"cvssV4_0\": {\"version\": \"4.0\", \"baseScore\": 5.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:L/UI:N/VC:L/VI:L/VA:L/SC:N/SI:N/SA:N\"}}, {\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 6.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\"}}, {\"cvssV3_0\": {\"version\": \"3.0\", \"baseScore\": 6.3, \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.0/AV:N/AC:L/PR:L/UI:N/S:U/C:L/I:L/A:L\"}}, {\"cvssV2_0\": {\"version\": \"2.0\", \"baseScore\": 6.5, \"vectorString\": \"AV:N/AC:L/Au:S/C:P/I:P/A:P\"}}], \"affected\": [{\"vendor\": \"Linksys\", \"product\": \"RE6500\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.013.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.002\"}, {\"status\": \"affected\", \"version\": \"1.1.05.003\"}, {\"status\": \"affected\", \"version\": \"1.2.07.001\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE6250\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.013.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.002\"}, {\"status\": \"affected\", \"version\": \"1.1.05.003\"}, {\"status\": \"affected\", \"version\": \"1.2.07.001\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE6300\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.013.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.002\"}, {\"status\": \"affected\", \"version\": \"1.1.05.003\"}, {\"status\": \"affected\", \"version\": \"1.2.07.001\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE6350\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.013.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.002\"}, {\"status\": \"affected\", \"version\": \"1.1.05.003\"}, {\"status\": \"affected\", \"version\": \"1.2.07.001\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE7000\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.013.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.002\"}, {\"status\": \"affected\", \"version\": \"1.1.05.003\"}, {\"status\": \"affected\", \"version\": \"1.2.07.001\"}]}, {\"vendor\": \"Linksys\", \"product\": \"RE9000\", \"versions\": [{\"status\": \"affected\", \"version\": \"1.0.013.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.001\"}, {\"status\": \"affected\", \"version\": \"1.0.04.002\"}, {\"status\": \"affected\", \"version\": \"1.1.05.003\"}, {\"status\": \"affected\", \"version\": \"1.2.07.001\"}]}], \"timeline\": [{\"lang\": \"en\", \"time\": \"2025-06-01T00:00:00.000Z\", \"value\": \"Advisory disclosed\"}, {\"lang\": \"en\", \"time\": \"2025-06-01T02:00:00.000Z\", \"value\": \"VulDB entry created\"}, {\"lang\": \"en\", \"time\": \"2025-06-01T19:11:51.000Z\", \"value\": \"VulDB entry last update\"}], \"references\": [{\"url\": \"https://vuldb.com/?id.310782\", \"name\": \"VDB-310782 | Linksys RE6500/RE6250/RE6300/RE6350/RE7000/RE9000 wirelessAdvancedHidden os command injection\", \"tags\": [\"vdb-entry\", \"technical-description\"]}, {\"url\": \"https://vuldb.com/?ctiid.310782\", \"name\": \"VDB-310782 | CTI Indicators (IOB, IOC, TTP, IOA)\", \"tags\": [\"signature\", \"permissions-required\"]}, {\"url\": \"https://vuldb.com/?submit.584365\", \"name\": \"Submit #584365 | Linksys RE6500\\u3001RE6250\\u3001RE6300\\u3001RE6350\\u3001RE7000\\u3001RE9000 RE6500(1.0.013.001) RE6250(1.0.04.001) RE6300(1.2.07.001) RE6350(1.0.04.001) RE7000(1.1.05.003) RE9000(1.0.04.002) OS Command Injection\", \"tags\": [\"third-party-advisory\"]}, {\"url\": \"https://github.com/wudipjq/my_vuln/blob/main/Linksys/vuln_6/6.md\", \"tags\": [\"exploit\"]}, {\"url\": \"https://www.linksys.com/\", \"tags\": [\"product\"]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability, which was classified as critical, was found in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001. Affected is the function wirelessAdvancedHidden of the file /goform/wirelessAdvancedHidden. The manipulation of the argument ExtChSelector/24GSelector/5GSelector leads to os command injection. It is possible to launch the attack remotely. The exploit has been disclosed to the public and may be used. The vendor was contacted early about this disclosure but did not respond in any way.\"}, {\"lang\": \"de\", \"value\": \"Es wurde eine Schwachstelle in Linksys RE6500, RE6250, RE6300, RE6350, RE7000 and RE9000 1.0.013.001/1.0.04.001/1.0.04.002/1.1.05.003/1.2.07.001 gefunden. Sie wurde als kritisch eingestuft. Es geht dabei um die Funktion wirelessAdvancedHidden der Datei /goform/wirelessAdvancedHidden. Durch Beeinflussen des Arguments ExtChSelector/24GSelector/5GSelector mit unbekannten Daten kann eine os command injection-Schwachstelle ausgenutzt werden. Der Angriff kann \\u00fcber das Netzwerk passieren. Der Exploit steht zur \\u00f6ffentlichen Verf\\u00fcgung.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-78\", \"description\": \"OS Command Injection\"}]}, {\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-77\", \"description\": \"Command Injection\"}]}], \"providerMetadata\": {\"orgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"shortName\": \"VulDB\", \"dateUpdated\": \"2025-06-02T11:31:04.438Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-5443\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-06-02T16:29:14.101Z\", \"dateReserved\": \"2025-06-01T17:06:27.764Z\", \"assignerOrgId\": \"1af790b2-7ee1-4545-860a-a788eba489b5\", \"datePublished\": \"2025-06-02T11:31:04.438Z\", \"assignerShortName\": \"VulDB\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…