CVE-2025-59447 (GCVE-0-2025-59447)
Vulnerability from cvelistv5 – Published: 2025-10-06 00:00 – Updated: 2025-10-06 20:10
VLAI?
Summary
The YoSmart YoLink Smart Hub device 0382 exposes a UART debug interface. An attacker with direct physical access can leverage this interface to read a boot log, which includes network access credentials.
Severity ?
CWE
- CWE-497 - Exposure of Sensitive System Information to an Unauthorized Control Sphere
Assigner
References
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| YoSmart | YoLink Smart Hub |
Affected:
0382
(custom)
|
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2025-59447",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "partial"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-10-06T20:10:20.449420Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2025-10-06T20:10:34.726Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unknown",
"product": "YoLink Smart Hub",
"vendor": "YoSmart",
"versions": [
{
"status": "affected",
"version": "0382",
"versionType": "custom"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The YoSmart YoLink Smart Hub device 0382 exposes a UART debug interface. An attacker with direct physical access can leverage this interface to read a boot log, which includes network access credentials."
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 2.2,
"baseSeverity": "LOW",
"vectorString": "CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:C/C:L/I:N/A:N",
"version": "3.1"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-497",
"description": "CWE-497 Exposure of Sensitive System Information to an Unauthorized Control Sphere",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-10-06T19:53:20.201Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://bishopfox.com/blog/advisories"
},
{
"url": "https://shop.yosmart.com/pages/product-support"
},
{
"url": "https://bishopfox.com/blog/how-a-20-smart-device-gave-me-access-to-your-home"
}
],
"x_generator": {
"engine": "enrichogram 0.0.1"
}
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-59447",
"datePublished": "2025-10-06T00:00:00.000Z",
"dateReserved": "2025-09-16T00:00:00.000Z",
"dateUpdated": "2025-10-06T20:10:34.726Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.1",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-59447\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2025-10-06T20:15:36.030\",\"lastModified\":\"2025-10-08T19:38:32.610\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The YoSmart YoLink Smart Hub device 0382 exposes a UART debug interface. An attacker with direct physical access can leverage this interface to read a boot log, which includes network access credentials.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"cve@mitre.org\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:C/C:L/I:N/A:N\",\"baseScore\":2.2,\"baseSeverity\":\"LOW\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"HIGH\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"LOW\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":0.5,\"impactScore\":1.4}]},\"weaknesses\":[{\"source\":\"cve@mitre.org\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-497\"}]}],\"references\":[{\"url\":\"https://bishopfox.com/blog/advisories\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://bishopfox.com/blog/how-a-20-smart-device-gave-me-access-to-your-home\",\"source\":\"cve@mitre.org\"},{\"url\":\"https://shop.yosmart.com/pages/product-support\",\"source\":\"cve@mitre.org\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-59447\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-10-06T20:10:20.449420Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-10-06T20:10:22.466Z\"}}], \"cna\": {\"metrics\": [{\"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 2.2, \"baseSeverity\": \"LOW\", \"vectorString\": \"CVSS:3.1/AV:P/AC:H/PR:N/UI:N/S:C/C:L/I:N/A:N\"}}], \"affected\": [{\"vendor\": \"YoSmart\", \"product\": \"YoLink Smart Hub\", \"versions\": [{\"status\": \"affected\", \"version\": \"0382\", \"versionType\": \"custom\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://bishopfox.com/blog/advisories\"}, {\"url\": \"https://shop.yosmart.com/pages/product-support\"}, {\"url\": \"https://bishopfox.com/blog/how-a-20-smart-device-gave-me-access-to-your-home\"}], \"x_generator\": {\"engine\": \"enrichogram 0.0.1\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"The YoSmart YoLink Smart Hub device 0382 exposes a UART debug interface. An attacker with direct physical access can leverage this interface to read a boot log, which includes network access credentials.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-497\", \"description\": \"CWE-497 Exposure of Sensitive System Information to an Unauthorized Control Sphere\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2025-10-06T19:53:20.201Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-59447\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-10-06T20:10:34.726Z\", \"dateReserved\": \"2025-09-16T00:00:00.000Z\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2025-10-06T00:00:00.000Z\", \"assignerShortName\": \"mitre\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.1"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…