CVE-2025-59694 (GCVE-0-2025-59694)
Vulnerability from cvelistv5 – Published: 2025-12-02 00:00 – Updated: 2025-12-03 16:08
VLAI?
Summary
The Chassis Management Board in Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allows a physically proximate attacker to persistently modify firmware and influence the (insecurely configured) appliance boot process. To exploit this, the attacker must modify the firmware via JTAG or perform an upgrade to the chassis management board firmware. This is called F03.
Severity ?
6.8 (Medium)
CWE
- n/a
Assigner
References
{
"containers": {
"adp": [
{
"metrics": [
{
"cvssV3_1": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "HIGH",
"baseScore": 6.8,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
}
},
{
"other": {
"content": {
"id": "CVE-2025-59694",
"options": [
{
"Exploitation": "poc"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2025-12-03T16:08:17.020915Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-1274",
"description": "CWE-1274 Improper Access Control for Volatile Memory Containing Boot Code",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-03T16:08:20.902Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"references": [
{
"tags": [
"exploit"
],
"url": "https://github.com/google/security-research/security/advisories/GHSA-6q4x-m86j-gfwj"
}
],
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"product": "n/a",
"vendor": "n/a",
"versions": [
{
"status": "affected",
"version": "n/a"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "The Chassis Management Board in Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allows a physically proximate attacker to persistently modify firmware and influence the (insecurely configured) appliance boot process. To exploit this, the attacker must modify the firmware via JTAG or perform an upgrade to the chassis management board firmware. This is called F03."
}
],
"problemTypes": [
{
"descriptions": [
{
"description": "n/a",
"lang": "en",
"type": "text"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2025-12-02T14:32:28.436Z",
"orgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"shortName": "mitre"
},
"references": [
{
"url": "https://www.entrust.com/use-case/why-use-an-hsm"
},
{
"url": "https://github.com/google/security-research/security/advisories/GHSA-6q4x-m86j-gfwj"
}
]
}
},
"cveMetadata": {
"assignerOrgId": "8254265b-2729-46b6-b9e3-3dfca2d5bfca",
"assignerShortName": "mitre",
"cveId": "CVE-2025-59694",
"datePublished": "2025-12-02T00:00:00.000Z",
"dateReserved": "2025-09-18T00:00:00.000Z",
"dateUpdated": "2025-12-03T16:08:20.902Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2025-59694\",\"sourceIdentifier\":\"cve@mitre.org\",\"published\":\"2025-12-02T15:15:54.883\",\"lastModified\":\"2025-12-15T13:39:22.617\",\"vulnStatus\":\"Analyzed\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"The Chassis Management Board in Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allows a physically proximate attacker to persistently modify firmware and influence the (insecurely configured) appliance boot process. To exploit this, the attacker must modify the firmware via JTAG or perform an upgrade to the chassis management board firmware. This is called F03.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":6.8,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"PHYSICAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":0.9,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-1274\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:entrust:nshield_5c_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.6.12\",\"matchCriteriaId\":\"CFB3D135-8EAC-4053-BB94-18D5BBB24AE7\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:entrust:nshield_5c_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.7.3\",\"versionEndExcluding\":\"13.9.0\",\"matchCriteriaId\":\"A225C602-A46C-43A1-B6ED-D85CE086FB13\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:entrust:nshield_5c:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"2BB0F3F8-F5DE-41CB-B804-BBFB78C6ADEB\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:entrust:nshield_hsmi_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.6.12\",\"matchCriteriaId\":\"ED3AEBBD-7F75-47F1-8EEA-342BAC9D265E\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:entrust:nshield_hsmi_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.7.3\",\"versionEndExcluding\":\"13.9.0\",\"matchCriteriaId\":\"8CA1F545-ADAE-41BF-946A-CEAD5A751BB7\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:entrust:nshield_hsmi:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F7665EE9-9F7F-456F-B172-ED188DD3BAD4\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:entrust:nshield_connect_xc_base_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.6.12\",\"matchCriteriaId\":\"F73858FD-5FE6-4AFA-84F2-E19743E9D900\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:entrust:nshield_connect_xc_base_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.7.3\",\"versionEndExcluding\":\"13.9.0\",\"matchCriteriaId\":\"65C6EC9C-C33D-4C37-ACD3-4B78D6291000\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:entrust:nshield_connect_xc_base:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"18FCA0E9-EEA9-40EC-9E0F-942F049D2354\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:entrust:nshield_connect_xc_mid_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.6.12\",\"matchCriteriaId\":\"5A54F973-25D8-468D-B6A4-240A95D94A0B\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:entrust:nshield_connect_xc_mid_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.7.3\",\"versionEndExcluding\":\"13.9.0\",\"matchCriteriaId\":\"125D948A-49AA-4385-8519-081F0787417E\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:entrust:nshield_connect_xc_mid:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"CB0ACAD9-BBCE-43CC-BD84-2023885725EE\"}]}]},{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:entrust:nshield_connect_xc_high_firmware:*:*:*:*:*:*:*:*\",\"versionEndExcluding\":\"13.6.12\",\"matchCriteriaId\":\"CBC11D8B-D72E-4CE9-AE61-AEA85F122F22\"},{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:entrust:nshield_connect_xc_high_firmware:*:*:*:*:*:*:*:*\",\"versionStartIncluding\":\"13.7.3\",\"versionEndExcluding\":\"13.9.0\",\"matchCriteriaId\":\"7779DADF-6D63-4326-981F-BA10860BBDD9\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:entrust:nshield_connect_xc_high:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3F0EDB1F-932B-4EC5-9D09-03CAD98BC2FA\"}]}]}],\"references\":[{\"url\":\"https://github.com/google/security-research/security/advisories/GHSA-6q4x-m86j-gfwj\",\"source\":\"cve@mitre.org\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]},{\"url\":\"https://www.entrust.com/use-case/why-use-an-hsm\",\"source\":\"cve@mitre.org\",\"tags\":[\"Product\"]},{\"url\":\"https://github.com/google/security-research/security/advisories/GHSA-6q4x-m86j-gfwj\",\"source\":\"134c704f-9b21-4f2e-91b3-4a467353bcc0\",\"tags\":[\"Exploit\",\"Third Party Advisory\"]}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 6.8, \"attackVector\": \"PHYSICAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"NONE\", \"confidentialityImpact\": \"HIGH\"}}, {\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-59694\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"poc\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-12-03T16:08:17.020915Z\"}}}], \"references\": [{\"url\": \"https://github.com/google/security-research/security/advisories/GHSA-6q4x-m86j-gfwj\", \"tags\": [\"exploit\"]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-1274\", \"description\": \"CWE-1274 Improper Access Control for Volatile Memory Containing Boot Code\"}]}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-12-03T16:07:58.195Z\"}}], \"cna\": {\"affected\": [{\"vendor\": \"n/a\", \"product\": \"n/a\", \"versions\": [{\"status\": \"affected\", \"version\": \"n/a\"}]}], \"references\": [{\"url\": \"https://www.entrust.com/use-case/why-use-an-hsm\"}, {\"url\": \"https://github.com/google/security-research/security/advisories/GHSA-6q4x-m86j-gfwj\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"The Chassis Management Board in Entrust nShield Connect XC, nShield 5c, and nShield HSMi through 13.6.11, or 13.7, allows a physically proximate attacker to persistently modify firmware and influence the (insecurely configured) appliance boot process. To exploit this, the attacker must modify the firmware via JTAG or perform an upgrade to the chassis management board firmware. This is called F03.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"text\", \"description\": \"n/a\"}]}], \"providerMetadata\": {\"orgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"shortName\": \"mitre\", \"dateUpdated\": \"2025-12-02T14:32:28.436Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2025-59694\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-12-03T16:08:20.902Z\", \"dateReserved\": \"2025-09-18T00:00:00.000Z\", \"assignerOrgId\": \"8254265b-2729-46b6-b9e3-3dfca2d5bfca\", \"datePublished\": \"2025-12-02T00:00:00.000Z\", \"assignerShortName\": \"mitre\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…