CVE-2025-9060 (GCVE-0-2025-9060)

Vulnerability from cvelistv5 – Published: 2025-08-15 16:25 – Updated: 2025-08-15 17:51
VLAI?
Summary
A vulnerability has been found in the  MSoft MFlash application that allows execution of arbitrary code on the server. The issue occurs in the integration configuration functionality that is only available to MFlash administrators. The vulnerability is related to insufficient validation of parameters when setting up security components. This issue affects MFlash v. 8.0 and possibly others. To mitigate apply 8.2-653 hotfix 11.06.2025 and above.
CWE
  • CWE-20 - Improper Input Validation
Assigner
Impacted products
Vendor Product Version
MSoft MFlash Affected: 8.0
Create a notification for this product.
Credits
The vulnerability was discovered by Marsel Shagiev and Evgeny Velikoivanenko from Kaspersky (https://kaspersky.com)
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2025-9060",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "total"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2025-08-15T17:51:40.064538Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2025-08-15T17:51:51.859Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "MFlash",
          "vendor": "MSoft",
          "versions": [
            {
              "status": "affected",
              "version": "8.0"
            }
          ]
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "The vulnerability was discovered by Marsel Shagiev and Evgeny Velikoivanenko from Kaspersky (https://kaspersky.com)"
        }
      ],
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "A vulnerability has been found in the \u0026nbsp;MSoft MFlash\n\n application that allows \nexecution of arbitrary code on the server. The issue occurs in the \nintegration configuration functionality that is only available to \nMFlash\n\n\n administrators. The vulnerability is related to insufficient validation\n of parameters when setting up security components.\n\n\u003cp\u003eThis issue affects MFlash v. 8.0 and possibly others. To mitigate apply\u0026nbsp;8.2-653 hotfix 11.06.2025 and above.\u003c/p\u003e"
            }
          ],
          "value": "A vulnerability has been found in the \u00a0MSoft MFlash\n\n application that allows \nexecution of arbitrary code on the server. The issue occurs in the \nintegration configuration functionality that is only available to \nMFlash\n\n\n administrators. The vulnerability is related to insufficient validation\n of parameters when setting up security components.\n\nThis issue affects MFlash v. 8.0 and possibly others. To mitigate apply\u00a08.2-653 hotfix 11.06.2025 and above."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-88",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-88 OS Command Injection"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "NETWORK",
            "availabilityImpact": "HIGH",
            "baseScore": 9.1,
            "baseSeverity": "CRITICAL",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "HIGH",
            "privilegesRequired": "HIGH",
            "scope": "CHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-20",
              "description": "CWE-20 Improper Input Validation",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2025-08-15T16:25:21.405Z",
        "orgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
        "shortName": "Kaspersky"
      },
      "references": [
        {
          "url": "https://github.com/klsecservices/Advisories/blob/master/K-MSoft-2025-002.md"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "title": "MFlash Remote Code Execution (RCE) after authentication of a user with the \"administrator\" role",
      "x_generator": {
        "engine": "Vulnogram 0.2.0"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "e45d732a-8f6b-4b6b-be76-7420f6a2b988",
    "assignerShortName": "Kaspersky",
    "cveId": "CVE-2025-9060",
    "datePublished": "2025-08-15T16:25:21.405Z",
    "dateReserved": "2025-08-15T11:02:05.206Z",
    "dateUpdated": "2025-08-15T17:51:51.859Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "nvd": "{\"cve\":{\"id\":\"CVE-2025-9060\",\"sourceIdentifier\":\"vulnerability@kaspersky.com\",\"published\":\"2025-08-15T17:15:34.887\",\"lastModified\":\"2025-08-18T20:16:28.750\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A vulnerability has been found in the \u00a0MSoft MFlash\\n\\n application that allows \\nexecution of arbitrary code on the server. The issue occurs in the \\nintegration configuration functionality that is only available to \\nMFlash\\n\\n\\n administrators. The vulnerability is related to insufficient validation\\n of parameters when setting up security components.\\n\\nThis issue affects MFlash v. 8.0 and possibly others. To mitigate apply\u00a08.2-653 hotfix 11.06.2025 and above.\"},{\"lang\":\"es\",\"value\":\"Se ha detectado una vulnerabilidad en la aplicaci\u00f3n MSoft MFlash que permite la ejecuci\u00f3n de c\u00f3digo arbitrario en el servidor. El problema se produce en la funci\u00f3n de configuraci\u00f3n de integraci\u00f3n, disponible \u00fanicamente para los administradores de MFlash. La vulnerabilidad se relaciona con una validaci\u00f3n insuficiente de los par\u00e1metros al configurar los componentes de seguridad. Este problema afecta a MFlash v. 8.0 y posiblemente a otras versiones. Para mitigarlo, aplique la revisi\u00f3n 8.2-653 11.06.2025 y posteriores.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"vulnerability@kaspersky.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\",\"baseScore\":9.1,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"HIGH\",\"userInteraction\":\"NONE\",\"scope\":\"CHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":2.3,\"impactScore\":6.0}]},\"weaknesses\":[{\"source\":\"vulnerability@kaspersky.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-20\"}]}],\"references\":[{\"url\":\"https://github.com/klsecservices/Advisories/blob/master/K-MSoft-2025-002.md\",\"source\":\"vulnerability@kaspersky.com\"}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2025-9060\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2025-08-15T17:51:40.064538Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2025-08-15T17:51:45.475Z\"}}], \"cna\": {\"title\": \"MFlash Remote Code Execution (RCE) after authentication of a user with the \\\"administrator\\\" role\", \"source\": {\"discovery\": \"UNKNOWN\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"The vulnerability was discovered by Marsel Shagiev and Evgeny Velikoivanenko from Kaspersky (https://kaspersky.com)\"}], \"impacts\": [{\"capecId\": \"CAPEC-88\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-88 OS Command Injection\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"CHANGED\", \"version\": \"3.1\", \"baseScore\": 9.1, \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"vectorString\": \"CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H\", \"integrityImpact\": \"HIGH\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"HIGH\", \"privilegesRequired\": \"HIGH\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"MSoft\", \"product\": \"MFlash\", \"versions\": [{\"status\": \"affected\", \"version\": \"8.0\"}], \"defaultStatus\": \"unknown\"}], \"references\": [{\"url\": \"https://github.com/klsecservices/Advisories/blob/master/K-MSoft-2025-002.md\"}], \"x_generator\": {\"engine\": \"Vulnogram 0.2.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"A vulnerability has been found in the \\u00a0MSoft MFlash\\n\\n application that allows \\nexecution of arbitrary code on the server. The issue occurs in the \\nintegration configuration functionality that is only available to \\nMFlash\\n\\n\\n administrators. The vulnerability is related to insufficient validation\\n of parameters when setting up security components.\\n\\nThis issue affects MFlash v. 8.0 and possibly others. To mitigate apply\\u00a08.2-653 hotfix 11.06.2025 and above.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"A vulnerability has been found in the \u0026nbsp;MSoft MFlash\\n\\n application that allows \\nexecution of arbitrary code on the server. The issue occurs in the \\nintegration configuration functionality that is only available to \\nMFlash\\n\\n\\n administrators. The vulnerability is related to insufficient validation\\n of parameters when setting up security components.\\n\\n\u003cp\u003eThis issue affects MFlash v. 8.0 and possibly others. To mitigate apply\u0026nbsp;8.2-653 hotfix 11.06.2025 and above.\u003c/p\u003e\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-20\", \"description\": \"CWE-20 Improper Input Validation\"}]}], \"providerMetadata\": {\"orgId\": \"e45d732a-8f6b-4b6b-be76-7420f6a2b988\", \"shortName\": \"Kaspersky\", \"dateUpdated\": \"2025-08-15T16:25:21.405Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2025-9060\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2025-08-15T17:51:51.859Z\", \"dateReserved\": \"2025-08-15T11:02:05.206Z\", \"assignerOrgId\": \"e45d732a-8f6b-4b6b-be76-7420f6a2b988\", \"datePublished\": \"2025-08-15T16:25:21.405Z\", \"assignerShortName\": \"Kaspersky\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…