CVE-2026-26221 (GCVE-0-2026-26221)
Vulnerability from cvelistv5 – Published: 2026-02-13 15:21 – Updated: 2026-02-13 17:10
VLAI?
Title
Hyland OnBase Timer Services Unauthenticated .NET Remoting RCE
Summary
Hyland OnBase contains an unauthenticated .NET Remoting exposure in the OnBase Workflow Timer Service (Hyland.Core.Workflow.NTService.exe). An attacker who can reach the service can send crafted .NET Remoting requests to default HTTP channel endpoints on TCP/8900 (e.g., TimerServiceAPI.rem and TimerServiceEvents.rem for Workflow) to trigger unsafe object unmarshalling, enabling arbitrary file read/write. By writing attacker-controlled content into web-accessible locations or chaining with other OnBase features, this can lead to remote code execution. The same primitive can be abused by supplying a UNC path to coerce outbound NTLM authentication (SMB coercion) to an attacker-controlled host.
Severity ?
CWE
- CWE-502 - Deserialization of Untrusted Data
Assigner
References
| URL | Tags | ||||||||||
|---|---|---|---|---|---|---|---|---|---|---|---|
|
|||||||||||
Impacted products
| Vendor | Product | Version | ||
|---|---|---|---|---|
| Hyland | OnBase Workflow Timer Service |
Affected:
8.0 , ≤ 17.0.x
(semver)
|
Credits
Victor A. Morales, Senior Pentester Team Leader, GM SecTec Inc.
VulnCheck
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-26221",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "yes"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-02-13T15:37:28.328195Z",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-02-13T15:37:35.046Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"modules": [
"Hyland.Core.Workflow.NTService.exe"
],
"product": "OnBase Workflow Timer Service",
"vendor": "Hyland",
"versions": [
{
"lessThanOrEqual": "17.0.x",
"status": "affected",
"version": "8.0",
"versionType": "semver"
}
]
}
],
"credits": [
{
"lang": "en",
"type": "finder",
"value": "Victor A. Morales, Senior Pentester Team Leader, GM SecTec Inc."
},
{
"lang": "en",
"type": "coordinator",
"value": "VulnCheck"
}
],
"descriptions": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "Hyland OnBase contains an unauthenticated .NET Remoting exposure in the OnBase Workflow Timer Service (Hyland.Core.Workflow.NTService.exe). An attacker who can reach the service can send crafted .NET Remoting requests to default HTTP channel endpoints on TCP/8900 (e.g., TimerServiceAPI.rem and TimerServiceEvents.rem for Workflow) to trigger unsafe object unmarshalling, enabling arbitrary file read/write. By writing attacker-controlled content into web-accessible locations or chaining with other OnBase features, this can lead to remote code execution. The same primitive can be abused by supplying a UNC path to coerce outbound NTLM authentication (SMB coercion) to an attacker-controlled host."
}
],
"value": "Hyland OnBase contains an unauthenticated .NET Remoting exposure in the OnBase Workflow Timer Service (Hyland.Core.Workflow.NTService.exe). An attacker who can reach the service can send crafted .NET Remoting requests to default HTTP channel endpoints on TCP/8900 (e.g., TimerServiceAPI.rem and TimerServiceEvents.rem for Workflow) to trigger unsafe object unmarshalling, enabling arbitrary file read/write. By writing attacker-controlled content into web-accessible locations or chaining with other OnBase features, this can lead to remote code execution. The same primitive can be abused by supplying a UNC path to coerce outbound NTLM authentication (SMB coercion) to an attacker-controlled host."
}
],
"metrics": [
{
"cvssV4_0": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"baseScore": 10,
"baseSeverity": "CRITICAL",
"exploitMaturity": "NOT_DEFINED",
"privilegesRequired": "NONE",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "HIGH",
"subConfidentialityImpact": "HIGH",
"subIntegrityImpact": "HIGH",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-502",
"description": "CWE-502 Deserialization of Untrusted Data",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-02-13T17:10:26.532Z",
"orgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"shortName": "VulnCheck"
},
"references": [
{
"tags": [
"product"
],
"url": "https://www.hyland.com/en/solutions/products/onbase"
},
{
"tags": [
"vendor-advisory",
"mitigation",
"permissions-required"
],
"url": "https://community.hyland.com/resources/bulletins-and-notices/223223-security-update-onbase-workflow-timer-service-bulletin-ob2025-03"
},
{
"tags": [
"third-party-advisory"
],
"url": "https://www.vulncheck.com/advisories/hyland-onbase-timer-services-unauthenticated-net-remoting-rce"
}
],
"source": {
"discovery": "EXTERNAL"
},
"title": "Hyland OnBase Timer Services Unauthenticated .NET Remoting RCE",
"workarounds": [
{
"lang": "en",
"supportingMedia": [
{
"base64": false,
"type": "text/html",
"value": "It is recommended that customers immediately convert to the in-servicing module, Unity Scheduler, and uninstall the Workflow Timer Service (Hyland.Core.Workflow.NTService.exe). Starting with OnBase 16, Unity Scheduler is the recommended replacement. It is recommended customers using versions prior to 16 upgrade to an in-servicing release of OnBase and leverage Unity Scheduler.\u003cbr\u003e"
}
],
"value": "It is recommended that customers immediately convert to the in-servicing module, Unity Scheduler, and uninstall the Workflow Timer Service (Hyland.Core.Workflow.NTService.exe). Starting with OnBase 16, Unity Scheduler is the recommended replacement. It is recommended customers using versions prior to 16 upgrade to an in-servicing release of OnBase and leverage Unity Scheduler."
}
],
"x_generator": {
"engine": "Vulnogram 0.5.0"
}
}
},
"cveMetadata": {
"assignerOrgId": "83251b91-4cc7-4094-a5c7-464a1b83ea10",
"assignerShortName": "VulnCheck",
"cveId": "CVE-2026-26221",
"datePublished": "2026-02-13T15:21:48.928Z",
"dateReserved": "2026-02-11T20:08:07.945Z",
"dateUpdated": "2026-02-13T17:10:26.532Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"nvd": "{\"cve\":{\"id\":\"CVE-2026-26221\",\"sourceIdentifier\":\"disclosure@vulncheck.com\",\"published\":\"2026-02-13T16:16:11.683\",\"lastModified\":\"2026-02-13T21:43:11.137\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"Hyland OnBase contains an unauthenticated .NET Remoting exposure in the OnBase Workflow Timer Service (Hyland.Core.Workflow.NTService.exe). An attacker who can reach the service can send crafted .NET Remoting requests to default HTTP channel endpoints on TCP/8900 (e.g., TimerServiceAPI.rem and TimerServiceEvents.rem for Workflow) to trigger unsafe object unmarshalling, enabling arbitrary file read/write. By writing attacker-controlled content into web-accessible locations or chaining with other OnBase features, this can lead to remote code execution. The same primitive can be abused by supplying a UNC path to coerce outbound NTLM authentication (SMB coercion) to an attacker-controlled host.\"}],\"metrics\":{\"cvssMetricV40\":[{\"source\":\"disclosure@vulncheck.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"4.0\",\"vectorString\":\"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X\",\"baseScore\":10.0,\"baseSeverity\":\"CRITICAL\",\"attackVector\":\"NETWORK\",\"attackComplexity\":\"LOW\",\"attackRequirements\":\"NONE\",\"privilegesRequired\":\"NONE\",\"userInteraction\":\"NONE\",\"vulnConfidentialityImpact\":\"HIGH\",\"vulnIntegrityImpact\":\"HIGH\",\"vulnAvailabilityImpact\":\"HIGH\",\"subConfidentialityImpact\":\"HIGH\",\"subIntegrityImpact\":\"HIGH\",\"subAvailabilityImpact\":\"HIGH\",\"exploitMaturity\":\"NOT_DEFINED\",\"confidentialityRequirement\":\"NOT_DEFINED\",\"integrityRequirement\":\"NOT_DEFINED\",\"availabilityRequirement\":\"NOT_DEFINED\",\"modifiedAttackVector\":\"NOT_DEFINED\",\"modifiedAttackComplexity\":\"NOT_DEFINED\",\"modifiedAttackRequirements\":\"NOT_DEFINED\",\"modifiedPrivilegesRequired\":\"NOT_DEFINED\",\"modifiedUserInteraction\":\"NOT_DEFINED\",\"modifiedVulnConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedVulnIntegrityImpact\":\"NOT_DEFINED\",\"modifiedVulnAvailabilityImpact\":\"NOT_DEFINED\",\"modifiedSubConfidentialityImpact\":\"NOT_DEFINED\",\"modifiedSubIntegrityImpact\":\"NOT_DEFINED\",\"modifiedSubAvailabilityImpact\":\"NOT_DEFINED\",\"Safety\":\"NOT_DEFINED\",\"Automatable\":\"NOT_DEFINED\",\"Recovery\":\"NOT_DEFINED\",\"valueDensity\":\"NOT_DEFINED\",\"vulnerabilityResponseEffort\":\"NOT_DEFINED\",\"providerUrgency\":\"NOT_DEFINED\"}}]},\"weaknesses\":[{\"source\":\"disclosure@vulncheck.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-502\"}]}],\"references\":[{\"url\":\"https://community.hyland.com/resources/bulletins-and-notices/223223-security-update-onbase-workflow-timer-service-bulletin-ob2025-03\",\"source\":\"disclosure@vulncheck.com\"},{\"url\":\"https://www.hyland.com/en/solutions/products/onbase\",\"source\":\"disclosure@vulncheck.com\"},{\"url\":\"https://www.vulncheck.com/advisories/hyland-onbase-timer-services-unauthenticated-net-remoting-rce\",\"source\":\"disclosure@vulncheck.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-26221\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-02-13T15:37:28.328195Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-02-13T15:37:30.868Z\"}}], \"cna\": {\"title\": \"Hyland OnBase Timer Services Unauthenticated .NET Remoting RCE\", \"source\": {\"discovery\": \"EXTERNAL\"}, \"credits\": [{\"lang\": \"en\", \"type\": \"finder\", \"value\": \"Victor A. Morales, Senior Pentester Team Leader, GM SecTec Inc.\"}, {\"lang\": \"en\", \"type\": \"coordinator\", \"value\": \"VulnCheck\"}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV4_0\": {\"Safety\": \"NOT_DEFINED\", \"version\": \"4.0\", \"Recovery\": \"NOT_DEFINED\", \"baseScore\": 10, \"Automatable\": \"NOT_DEFINED\", \"attackVector\": \"NETWORK\", \"baseSeverity\": \"CRITICAL\", \"valueDensity\": \"NOT_DEFINED\", \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:H/VI:H/VA:H/SC:H/SI:H/SA:H\", \"exploitMaturity\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"subIntegrityImpact\": \"HIGH\", \"vulnIntegrityImpact\": \"HIGH\", \"subAvailabilityImpact\": \"HIGH\", \"vulnAvailabilityImpact\": \"HIGH\", \"subConfidentialityImpact\": \"HIGH\", \"vulnConfidentialityImpact\": \"HIGH\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Hyland\", \"modules\": [\"Hyland.Core.Workflow.NTService.exe\"], \"product\": \"OnBase Workflow Timer Service\", \"versions\": [{\"status\": \"affected\", \"version\": \"8.0\", \"versionType\": \"semver\", \"lessThanOrEqual\": \"17.0.x\"}], \"defaultStatus\": \"unaffected\"}], \"references\": [{\"url\": \"https://www.hyland.com/en/solutions/products/onbase\", \"tags\": [\"product\"]}, {\"url\": \"https://community.hyland.com/resources/bulletins-and-notices/223223-security-update-onbase-workflow-timer-service-bulletin-ob2025-03\", \"tags\": [\"vendor-advisory\", \"mitigation\", \"permissions-required\"]}, {\"url\": \"https://www.vulncheck.com/advisories/hyland-onbase-timer-services-unauthenticated-net-remoting-rce\", \"tags\": [\"third-party-advisory\"]}], \"workarounds\": [{\"lang\": \"en\", \"value\": \"It is recommended that customers immediately convert to the in-servicing module, Unity Scheduler, and uninstall the Workflow Timer Service (Hyland.Core.Workflow.NTService.exe). Starting with OnBase 16, Unity Scheduler is the recommended replacement. It is recommended customers using versions prior to 16 upgrade to an in-servicing release of OnBase and leverage Unity Scheduler.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"It is recommended that customers immediately convert to the in-servicing module, Unity Scheduler, and uninstall the Workflow Timer Service (Hyland.Core.Workflow.NTService.exe). Starting with OnBase 16, Unity Scheduler is the recommended replacement. It is recommended customers using versions prior to 16 upgrade to an in-servicing release of OnBase and leverage Unity Scheduler.\u003cbr\u003e\", \"base64\": false}]}], \"x_generator\": {\"engine\": \"Vulnogram 0.5.0\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"Hyland OnBase contains an unauthenticated .NET Remoting exposure in the OnBase Workflow Timer Service (Hyland.Core.Workflow.NTService.exe). An attacker who can reach the service can send crafted .NET Remoting requests to default HTTP channel endpoints on TCP/8900 (e.g., TimerServiceAPI.rem and TimerServiceEvents.rem for Workflow) to trigger unsafe object unmarshalling, enabling arbitrary file read/write. By writing attacker-controlled content into web-accessible locations or chaining with other OnBase features, this can lead to remote code execution. The same primitive can be abused by supplying a UNC path to coerce outbound NTLM authentication (SMB coercion) to an attacker-controlled host.\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"Hyland OnBase contains an unauthenticated .NET Remoting exposure in the OnBase Workflow Timer Service (Hyland.Core.Workflow.NTService.exe). An attacker who can reach the service can send crafted .NET Remoting requests to default HTTP channel endpoints on TCP/8900 (e.g., TimerServiceAPI.rem and TimerServiceEvents.rem for Workflow) to trigger unsafe object unmarshalling, enabling arbitrary file read/write. By writing attacker-controlled content into web-accessible locations or chaining with other OnBase features, this can lead to remote code execution. The same primitive can be abused by supplying a UNC path to coerce outbound NTLM authentication (SMB coercion) to an attacker-controlled host.\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-502\", \"description\": \"CWE-502 Deserialization of Untrusted Data\"}]}], \"providerMetadata\": {\"orgId\": \"83251b91-4cc7-4094-a5c7-464a1b83ea10\", \"shortName\": \"VulnCheck\", \"dateUpdated\": \"2026-02-13T17:10:26.532Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-26221\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-02-13T17:10:26.532Z\", \"dateReserved\": \"2026-02-11T20:08:07.945Z\", \"assignerOrgId\": \"83251b91-4cc7-4094-a5c7-464a1b83ea10\", \"datePublished\": \"2026-02-13T15:21:48.928Z\", \"assignerShortName\": \"VulnCheck\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…