CVE-2026-27868 (GCVE-0-2026-27868)

Vulnerability from cvelistv5 – Published: 2026-06-17 08:13 – Updated: 2026-06-17 12:48
VLAI
Title
PUBLICATION OF SENSITIVE INFORMATION ON REGESTA SMART HD-PLC OF TELDAT
Summary
An attacker with access via network to the Regesta Smart HD-PLC of the provider Teldat (in this case, NO registration action is required) who has the vulnerable software could obtain privilege information by using the command Version via the path: /upgrade/query.php?cmd=p+3&3Bversion resulting in a information disclosure. This issue affects Regesta Smart HD-PLC - TLDPH16D2: 11.02.05.10.02.
SSVC
Exploitation: none Automatable: yes Technical Impact: partial
CISA Coordinator (v2.0.3)
CWE
  • CWE-201 - Insertion of sensitive information into sent data
Assigner
Impacted products
Vendor Product Version
Teldat Regesta Smart HD-PLC - TLDPH16D2 Affected: 11.02.05.10.02
Unaffected: 11.02.06.00.02
Create a notification for this product.
Date Public
2026-06-17 08:00
Credits
Aarón Flecha Menéndez Víctor Bello Cuevas
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2026-27868",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "yes"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2026-06-17T12:48:11.401061Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2026-06-17T12:48:19.633Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unknown",
          "product": "Regesta Smart HD-PLC - TLDPH16D2",
          "vendor": "Teldat",
          "versions": [
            {
              "status": "affected",
              "version": "11.02.05.10.02"
            },
            {
              "status": "unaffected",
              "version": "11.02.06.00.02"
            }
          ]
        }
      ],
      "cpeApplicability": [
        {
          "nodes": [
            {
              "cpeMatch": [
                {
                  "criteria": "cpe:2.3:a:teldat:regesta_smart_hd-plc_-_tldph16d2:11.02.05.10.02:*:*:*:*:*:*:*",
                  "vulnerable": true
                },
                {
                  "criteria": "cpe:2.3:a:teldat:regesta_smart_hd-plc_-_tldph16d2:11.02.06.00.02:*:*:*:*:*:*:*",
                  "vulnerable": false
                }
              ],
              "negate": false,
              "operator": "OR"
            }
          ],
          "operator": "OR"
        }
      ],
      "credits": [
        {
          "lang": "en",
          "type": "finder",
          "value": "Aar\u00f3n Flecha Men\u00e9ndez"
        },
        {
          "lang": "en",
          "type": "finder",
          "value": "V\u00edctor Bello Cuevas"
        }
      ],
      "datePublic": "2026-06-17T08:00:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "An attacker with access via network to the Regesta Smart HD-PLC of the provider Teldat (in this case, NO registration action is required) who has the vulnerable software could obtain privilege information by using the command \u003cb\u003eVersion \u003c/b\u003evia the path: \u003ci\u003e/upgrade/query.php?cmd=p+3\u0026amp;3Bversion\u003c/i\u003e\u0026nbsp;resulting in a information disclosure.\u0026nbsp;\u003cspan\u003eT\u003c/span\u003e\u003cspan\u003ehis issue affects Regesta Smart HD-PLC - TLDPH16D2: \n11.02.05.10.02.\u003c/span\u003e\u003cbr\u003e"
            }
          ],
          "value": "An attacker with access via network to the Regesta Smart HD-PLC of the provider Teldat (in this case, NO registration action is required) who has the vulnerable software could obtain privilege information by using the command Version via the path: /upgrade/query.php?cmd=p+3\u00263Bversion\u00a0resulting in a information disclosure.\u00a0This issue affects Regesta Smart HD-PLC - TLDPH16D2: \n11.02.05.10.02."
        }
      ],
      "impacts": [
        {
          "capecId": "CAPEC-116",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-116 Excavation"
            }
          ]
        },
        {
          "capecId": "CAPEC-54",
          "descriptions": [
            {
              "lang": "en",
              "value": "CAPEC-54 Query System for Information"
            }
          ]
        }
      ],
      "metrics": [
        {
          "cvssV4_0": {
            "Automatable": "NOT_DEFINED",
            "Recovery": "NOT_DEFINED",
            "Safety": "NOT_DEFINED",
            "attackComplexity": "LOW",
            "attackRequirements": "NONE",
            "attackVector": "NETWORK",
            "baseScore": 6.9,
            "baseSeverity": "MEDIUM",
            "exploitMaturity": "NOT_DEFINED",
            "privilegesRequired": "NONE",
            "providerUrgency": "NOT_DEFINED",
            "subAvailabilityImpact": "NONE",
            "subConfidentialityImpact": "NONE",
            "subIntegrityImpact": "NONE",
            "userInteraction": "NONE",
            "valueDensity": "NOT_DEFINED",
            "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N",
            "version": "4.0",
            "vulnAvailabilityImpact": "NONE",
            "vulnConfidentialityImpact": "LOW",
            "vulnIntegrityImpact": "NONE",
            "vulnerabilityResponseEffort": "NOT_DEFINED"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-201",
              "description": "CWE-201 Insertion of sensitive information into sent data",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2026-06-17T11:43:43.412Z",
        "orgId": "ffb98d57-deaa-4918-a669-5225ccc13e39",
        "shortName": "HackRTU"
      },
      "references": [
        {
          "tags": [
            "technical-description",
            "patch"
          ],
          "url": "https://www.hackrtu.com/blog/CNA-HRTU-0002/"
        },
        {
          "tags": [
            "technical-description",
            "patch"
          ],
          "url": "https://www.hackrtu.com/blog/CNA-CVE-2026-27868/"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://www.teldat.com/es/"
        },
        {
          "tags": [
            "product"
          ],
          "url": "https://support.teldat.com/images/content/docs/Teldat_dm1087_regesta_smart_nessum_series_installation(1).pdf"
        },
        {
          "tags": [
            "patch"
          ],
          "url": "https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026none=true\u0026language=en-US"
        }
      ],
      "solutions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "The provider has implemented the new version\u0026nbsp;\n\u003cb\u003e11.02.06.00.02\u003c/b\u003e\u0026nbsp;\u0026nbsp;which solves the security problems detected in the affected version. The end user has to download the new version in the \u003cb\u003eTeldat - Client Support Portal\u003c/b\u003e and implement it in the device (\n\u003ca href=\"https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026amp;none=true\u0026amp;language=en-US\" title=\"https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026amp;none=true\u0026amp;language=en-US\"\u003ehttps://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026amp;none=true\u0026amp;language=en-US\u003c/a\u003e)."
            }
          ],
          "value": "The provider has implemented the new version\u00a0\n11.02.06.00.02\u00a0\u00a0which solves the security problems detected in the affected version. The end user has to download the new version in the Teldat - Client Support Portal and implement it in the device (\n https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026none=true\u0026language=en-US )."
        }
      ],
      "source": {
        "advisory": "HRTU#0003",
        "discovery": "EXTERNAL"
      },
      "timeline": [
        {
          "lang": "en",
          "time": "2026-02-20T09:00:00.000Z",
          "value": "Vulnerability detection by the researchers"
        },
        {
          "lang": "en",
          "time": "2026-02-22T09:00:00.000Z",
          "value": "Report from researchers to the CNA of HackRTU"
        },
        {
          "lang": "en",
          "time": "2026-02-25T09:00:00.000Z",
          "value": "Report from HackRTU CNA to the provider"
        },
        {
          "lang": "en",
          "time": "2026-05-29T08:00:00.000Z",
          "value": "New version published by the provider"
        },
        {
          "lang": "en",
          "time": "2026-06-17T08:00:00.000Z",
          "value": "Vulnerabilities published by HackRTU\u0027s CNA"
        }
      ],
      "title": "PUBLICATION OF SENSITIVE INFORMATION ON REGESTA SMART HD-PLC OF TELDAT",
      "x_generator": {
        "engine": "Vulnogram 1.0.2"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "ffb98d57-deaa-4918-a669-5225ccc13e39",
    "assignerShortName": "HackRTU",
    "cveId": "CVE-2026-27868",
    "datePublished": "2026-06-17T08:13:36.554Z",
    "dateReserved": "2026-02-24T08:59:28.139Z",
    "dateUpdated": "2026-06-17T12:48:19.633Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.2",
  "vulnerability-lookup:meta": {
    "epss": {
      "cve": "CVE-2026-27868",
      "date": "2026-06-17",
      "epss": "0.00524",
      "percentile": "0.40159"
    },
    "vulnrichment": {
      "containers": "{\"cna\": {\"providerMetadata\": {\"orgId\": \"ffb98d57-deaa-4918-a669-5225ccc13e39\", \"shortName\": \"HackRTU\", \"dateUpdated\": \"2026-06-17T11:43:43.412Z\"}, \"title\": \"PUBLICATION OF SENSITIVE INFORMATION ON REGESTA SMART HD-PLC OF TELDAT\", \"datePublic\": \"2026-06-17T08:00:00.000Z\", \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"cweId\": \"CWE-201\", \"description\": \"CWE-201 Insertion of sensitive information into sent data\", \"type\": \"CWE\"}]}], \"impacts\": [{\"capecId\": \"CAPEC-116\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-116 Excavation\"}]}, {\"capecId\": \"CAPEC-54\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-54 Query System for Information\"}]}], \"affected\": [{\"vendor\": \"Teldat\", \"product\": \"Regesta Smart HD-PLC - TLDPH16D2\", \"versions\": [{\"status\": \"affected\", \"version\": \"11.02.05.10.02\"}, {\"status\": \"unaffected\", \"version\": \"11.02.06.00.02\"}], \"defaultStatus\": \"unknown\"}], \"cpeApplicability\": [{\"operator\": \"OR\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:a:teldat:regesta_smart_hd-plc_-_tldph16d2:11.02.05.10.02:*:*:*:*:*:*:*\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:a:teldat:regesta_smart_hd-plc_-_tldph16d2:11.02.06.00.02:*:*:*:*:*:*:*\"}]}]}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"An attacker with access via network to the Regesta Smart HD-PLC of the provider Teldat (in this case, NO registration action is required) who has the vulnerable software could obtain privilege information by using the command Version via the path: /upgrade/query.php?cmd=p+3\u00263Bversion\\u00a0resulting in a information disclosure.\\u00a0This issue affects Regesta Smart HD-PLC - TLDPH16D2: \\n11.02.05.10.02.\", \"supportingMedia\": [{\"type\": \"text/html\", \"base64\": false, \"value\": \"An attacker with access via network to the Regesta Smart HD-PLC of the provider Teldat (in this case, NO registration action is required) who has the vulnerable software could obtain privilege information by using the command \u003cb\u003eVersion \u003c/b\u003evia the path: \u003ci\u003e/upgrade/query.php?cmd=p+3\u0026amp;3Bversion\u003c/i\u003e\u0026nbsp;resulting in a information disclosure.\u0026nbsp;\u003cspan\u003eT\u003c/span\u003e\u003cspan\u003ehis issue affects Regesta Smart HD-PLC - TLDPH16D2: \\n11.02.05.10.02.\u003c/span\u003e\u003cbr\u003e\"}]}], \"references\": [{\"url\": \"https://www.hackrtu.com/blog/CNA-HRTU-0002/\", \"tags\": [\"technical-description\", \"patch\"]}, {\"url\": \"https://www.hackrtu.com/blog/CNA-CVE-2026-27868/\", \"tags\": [\"technical-description\", \"patch\"]}, {\"url\": \"https://www.teldat.com/es/\", \"tags\": [\"product\"]}, {\"url\": \"https://support.teldat.com/images/content/docs/Teldat_dm1087_regesta_smart_nessum_series_installation(1).pdf\", \"tags\": [\"product\"]}, {\"url\": \"https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026none=true\u0026language=en-US\", \"tags\": [\"patch\"]}], \"metrics\": [{\"format\": \"CVSS\", \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}], \"cvssV4_0\": {\"attackVector\": \"NETWORK\", \"attackComplexity\": \"LOW\", \"attackRequirements\": \"NONE\", \"privilegesRequired\": \"NONE\", \"userInteraction\": \"NONE\", \"vulnConfidentialityImpact\": \"LOW\", \"subConfidentialityImpact\": \"NONE\", \"vulnIntegrityImpact\": \"NONE\", \"subIntegrityImpact\": \"NONE\", \"vulnAvailabilityImpact\": \"NONE\", \"subAvailabilityImpact\": \"NONE\", \"exploitMaturity\": \"NOT_DEFINED\", \"Safety\": \"NOT_DEFINED\", \"Automatable\": \"NOT_DEFINED\", \"Recovery\": \"NOT_DEFINED\", \"valueDensity\": \"NOT_DEFINED\", \"vulnerabilityResponseEffort\": \"NOT_DEFINED\", \"providerUrgency\": \"NOT_DEFINED\", \"version\": \"4.0\", \"baseSeverity\": \"MEDIUM\", \"baseScore\": 6.9, \"vectorString\": \"CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:L/VI:N/VA:N/SC:N/SI:N/SA:N\"}}], \"solutions\": [{\"lang\": \"en\", \"value\": \"The provider has implemented the new version\\u00a0\\n11.02.06.00.02\\u00a0\\u00a0which solves the security problems detected in the affected version. The end user has to download the new version in the Teldat - Client Support Portal and implement it in the device (\\n https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026none=true\u0026language=en-US ).\", \"supportingMedia\": [{\"type\": \"text/html\", \"base64\": false, \"value\": \"The provider has implemented the new version\u0026nbsp;\\n\u003cb\u003e11.02.06.00.02\u003c/b\u003e\u0026nbsp;\u0026nbsp;which solves the security problems detected in the affected version. The end user has to download the new version in the \u003cb\u003eTeldat - Client Support Portal\u003c/b\u003e and implement it in the device (\\n\u003ca href=\\\"https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026amp;none=true\u0026amp;language=en-US\\\" title=\\\"https://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026amp;none=true\u0026amp;language=en-US\\\"\u003ehttps://support.teldat.com/portal/supportcontent?page=cgs-customer-global-support\u0026amp;none=true\u0026amp;language=en-US\u003c/a\u003e).\"}]}], \"timeline\": [{\"time\": \"2026-02-20T09:00:00.000Z\", \"lang\": \"en\", \"value\": \"Vulnerability detection by the researchers\"}, {\"time\": \"2026-02-22T09:00:00.000Z\", \"lang\": \"en\", \"value\": \"Report from researchers to the CNA of HackRTU\"}, {\"time\": \"2026-02-25T09:00:00.000Z\", \"lang\": \"en\", \"value\": \"Report from HackRTU CNA to the provider\"}, {\"time\": \"2026-05-29T08:00:00.000Z\", \"lang\": \"en\", \"value\": \"New version published by the provider\"}, {\"time\": \"2026-06-17T08:00:00.000Z\", \"lang\": \"en\", \"value\": \"Vulnerabilities published by HackRTU\u0027s CNA\"}], \"credits\": [{\"lang\": \"en\", \"value\": \"Aar\\u00f3n Flecha Men\\u00e9ndez\", \"type\": \"finder\"}, {\"lang\": \"en\", \"value\": \"V\\u00edctor Bello Cuevas\", \"type\": \"finder\"}], \"source\": {\"advisory\": \"HRTU#0003\", \"discovery\": \"EXTERNAL\"}, \"x_generator\": {\"engine\": \"Vulnogram 1.0.2\"}}, \"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-27868\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"yes\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-06-17T12:48:11.401061Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-06-17T12:48:16.600Z\"}}]}",
      "cveMetadata": "{\"cveId\": \"CVE-2026-27868\", \"assignerOrgId\": \"ffb98d57-deaa-4918-a669-5225ccc13e39\", \"state\": \"PUBLISHED\", \"assignerShortName\": \"HackRTU\", \"dateReserved\": \"2026-02-24T08:59:28.139Z\", \"datePublished\": \"2026-06-17T08:13:36.554Z\", \"dateUpdated\": \"2026-06-17T12:48:19.633Z\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.2"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…