CVE-2026-40619 (GCVE-0-2026-40619)
Vulnerability from cvelistv5 – Published: 2026-06-02 14:37 – Updated: 2026-06-03 03:56
VLAI
Summary
A high security vulnerability affecting Security Center main server installations has been identified. It could allow an attacker with local OS privileges to the main server to access the Server Admin credentials. A third party hired by Genetec found the issue. There is currently no evidence of active exploitation.
This vulnerability is associated with specific installation package builds rather than the product version identifier alone. Certain versions (including 5.10.4.0, 5.11.3.0, 5.12.2.0 and 5.13.3.0) were released with both vulnerable and remediated installation packages under the same version number.
Consequently, version-based comparison alone is insufficient to determine exposure. Only installations performed using vulnerable builds are affected. Remediated builds can be distinguished using verified installation package hashes. For the complete list of fixed build hashes, refer to the security advisory section.
Severity
7.8 (High)
SSVC
Exploitation: none
Automatable: no
Technical Impact: total
CISA Coordinator (v2.0.3)
CWE
- CWE-532 - Insertion of Sensitive Information into Log File
Assigner
References
1 reference
Impacted products
1 product
| Vendor | Product | Version | |
|---|---|---|---|
| Genetec Inc. | Genetec Security Center |
Affected:
>=5.7 SR6 <=5.10.4.0
(semver)
Unaffected: >5.10.4.0 (semver) Affected: >=5.11.0.0 <=5.11.3.0 (semver) Unaffected: >5.11.3.0 (semver) Affected: >=5.12.0.0 <=5.12.2.0 (semver) Unaffected: >5.12.2.0 (semver) Affected: >=5.13.0.0 <=5.13.3.0 (semver) Unaffected: >5.13.3.0 (semver) Unaffected: >=5.14.0.0 (semver) |
{
"containers": {
"adp": [
{
"metrics": [
{
"other": {
"content": {
"id": "CVE-2026-40619",
"options": [
{
"Exploitation": "none"
},
{
"Automatable": "no"
},
{
"Technical Impact": "total"
}
],
"role": "CISA Coordinator",
"timestamp": "2026-06-02T00:00:00+00:00",
"version": "2.0.3"
},
"type": "ssvc"
}
}
],
"providerMetadata": {
"dateUpdated": "2026-06-03T03:56:05.022Z",
"orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"shortName": "CISA-ADP"
},
"title": "CISA ADP Vulnrichment"
}
],
"cna": {
"affected": [
{
"defaultStatus": "unaffected",
"platforms": [
"Windows"
],
"product": "Genetec Security Center",
"vendor": "Genetec Inc.",
"versions": [
{
"status": "affected",
"version": "\u003e=5.7 SR6 \u003c=5.10.4.0",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e5.10.4.0",
"versionType": "semver"
},
{
"status": "affected",
"version": "\u003e=5.11.0.0 \u003c=5.11.3.0",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e5.11.3.0",
"versionType": "semver"
},
{
"status": "affected",
"version": "\u003e=5.12.0.0 \u003c=5.12.2.0",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e5.12.2.0",
"versionType": "semver"
},
{
"status": "affected",
"version": "\u003e=5.13.0.0 \u003c=5.13.3.0",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e5.13.3.0",
"versionType": "semver"
},
{
"status": "unaffected",
"version": "\u003e=5.14.0.0",
"versionType": "semver"
}
]
}
],
"descriptions": [
{
"lang": "en",
"value": "A high security vulnerability affecting Security Center main server installations has been identified. It could allow an attacker with local OS privileges to the main server to access the Server Admin credentials. A third party hired by Genetec found the issue. There is currently no evidence of active exploitation.\n\nThis vulnerability is associated with specific installation package builds rather than the product version identifier alone. Certain versions (including 5.10.4.0, 5.11.3.0, 5.12.2.0 and 5.13.3.0) were released with both vulnerable and remediated installation packages under the same version number.\n\nConsequently, version-based comparison alone is insufficient to determine exposure. Only installations performed using vulnerable builds are affected. Remediated builds can be distinguished using verified installation package hashes. For the complete list of fixed build hashes, refer to the security advisory section."
}
],
"impacts": [
{
"capecId": "CAPEC-560",
"descriptions": [
{
"lang": "en",
"value": "CAPEC-560: Use of Known Domain Credentials"
}
]
}
],
"metrics": [
{
"cvssV3_1": {
"baseScore": 7.8,
"baseSeverity": "HIGH",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"format": "CVSS",
"scenarios": [
{
"lang": "en",
"value": "GENERAL"
}
]
}
],
"problemTypes": [
{
"descriptions": [
{
"cweId": "CWE-532",
"description": "CWE-532: Insertion of Sensitive Information into Log File",
"lang": "en",
"type": "CWE"
}
]
}
],
"providerMetadata": {
"dateUpdated": "2026-06-02T14:37:53.827Z",
"orgId": "f2b06212-cb4b-41a4-9501-fa2e367495b8",
"shortName": "Genetec"
},
"references": [
{
"url": "https://resources.genetec.com/security-advisories/vulnerability-affecting-security-center-systems-main-server-installations"
}
],
"solutions": [
{
"lang": "en",
"value": "Updated installation packages have been released for affected versions of Security Center. Installations performed using remediated builds are not vulnerable.\n\nFor versions that were distributed with both vulnerable and fixed installation packages under the same version number, the following hashes correspond to confirmed remediated builds:\n\n- Version 5.10.4.0 (4111.0): SHA1: A2133AB76ECA6988F23FCB83FFF95949E0738C07\n- Version 5.11.3.0 (3130.13): SHA1: 9427F5AF127E00DF41CF44AC233976DF56604FFD\n- Version 5.12.2.0 (2181.44): SHA256: B9284E55EC54EBBC36265EA5DE1272B7752B2A29DDC44804D5459DFC21C16609\n- Version 5.13.3.0 (3132.18): SHA256: 5E3B3C9D5A8C633489EFFF71D7883D4E2D89C28009CA2A1D0294FB3B19A79450\n\nCustomers should verify the integrity of their installation packages against these values to determine whether a fixed build is in use. If the package hash does not match a known remediated value, it should be considered vulnerable."
}
]
}
},
"cveMetadata": {
"assignerOrgId": "f2b06212-cb4b-41a4-9501-fa2e367495b8",
"assignerShortName": "Genetec",
"cveId": "CVE-2026-40619",
"datePublished": "2026-06-02T14:37:53.827Z",
"dateReserved": "2026-04-27T16:27:39.879Z",
"dateUpdated": "2026-06-03T03:56:05.022Z",
"state": "PUBLISHED"
},
"dataType": "CVE_RECORD",
"dataVersion": "5.2",
"vulnerability-lookup:meta": {
"epss": {
"cve": "CVE-2026-40619",
"date": "2026-06-06",
"epss": "0.00013",
"percentile": "0.02181"
},
"nvd": "{\"cve\":{\"id\":\"CVE-2026-40619\",\"sourceIdentifier\":\"security@genetec.com\",\"published\":\"2026-06-02T16:16:39.127\",\"lastModified\":\"2026-06-02T17:35:24.027\",\"vulnStatus\":\"Awaiting Analysis\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"A high security vulnerability affecting Security Center main server installations has been identified. It could allow an attacker with local OS privileges to the main server to access the Server Admin credentials. A third party hired by Genetec found the issue. There is currently no evidence of active exploitation.\\n\\nThis vulnerability is associated with specific installation package builds rather than the product version identifier alone. Certain versions (including 5.10.4.0, 5.11.3.0, 5.12.2.0 and 5.13.3.0) were released with both vulnerable and remediated installation packages under the same version number.\\n\\nConsequently, version-based comparison alone is insufficient to determine exposure. Only installations performed using vulnerable builds are affected. Remediated builds can be distinguished using verified installation package hashes. For the complete list of fixed build hashes, refer to the security advisory section.\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security@genetec.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\",\"baseScore\":7.8,\"baseSeverity\":\"HIGH\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"HIGH\",\"availabilityImpact\":\"HIGH\"},\"exploitabilityScore\":1.8,\"impactScore\":5.9}]},\"weaknesses\":[{\"source\":\"security@genetec.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-532\"}]}],\"references\":[{\"url\":\"https://resources.genetec.com/security-advisories/vulnerability-affecting-security-center-systems-main-server-installations\",\"source\":\"security@genetec.com\"}]}}",
"vulnrichment": {
"containers": "{\"adp\": [{\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2026-40619\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"total\"}], \"version\": \"2.0.3\", \"timestamp\": \"2026-06-02T16:07:13.748361Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2026-06-02T16:07:17.261Z\"}}], \"cna\": {\"impacts\": [{\"capecId\": \"CAPEC-560\", \"descriptions\": [{\"lang\": \"en\", \"value\": \"CAPEC-560: Use of Known Domain Credentials\"}]}], \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"version\": \"3.1\", \"baseScore\": 7.8, \"baseSeverity\": \"HIGH\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Genetec Inc.\", \"product\": \"Genetec Security Center\", \"versions\": [{\"status\": \"affected\", \"version\": \"\u003e=5.7 SR6 \u003c=5.10.4.0\", \"versionType\": \"semver\"}, {\"status\": \"unaffected\", \"version\": \"\u003e5.10.4.0\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"\u003e=5.11.0.0 \u003c=5.11.3.0\", \"versionType\": \"semver\"}, {\"status\": \"unaffected\", \"version\": \"\u003e5.11.3.0\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"\u003e=5.12.0.0 \u003c=5.12.2.0\", \"versionType\": \"semver\"}, {\"status\": \"unaffected\", \"version\": \"\u003e5.12.2.0\", \"versionType\": \"semver\"}, {\"status\": \"affected\", \"version\": \"\u003e=5.13.0.0 \u003c=5.13.3.0\", \"versionType\": \"semver\"}, {\"status\": \"unaffected\", \"version\": \"\u003e5.13.3.0\", \"versionType\": \"semver\"}, {\"status\": \"unaffected\", \"version\": \"\u003e=5.14.0.0\", \"versionType\": \"semver\"}], \"platforms\": [\"Windows\"], \"defaultStatus\": \"unaffected\"}], \"solutions\": [{\"lang\": \"en\", \"value\": \"Updated installation packages have been released for affected versions of Security Center. Installations performed using remediated builds are not vulnerable.\\n\\nFor versions that were distributed with both vulnerable and fixed installation packages under the same version number, the following hashes correspond to confirmed remediated builds:\\n\\n- Version 5.10.4.0 (4111.0): SHA1: A2133AB76ECA6988F23FCB83FFF95949E0738C07\\n- Version 5.11.3.0 (3130.13): SHA1: 9427F5AF127E00DF41CF44AC233976DF56604FFD\\n- Version 5.12.2.0 (2181.44): SHA256: B9284E55EC54EBBC36265EA5DE1272B7752B2A29DDC44804D5459DFC21C16609\\n- Version 5.13.3.0 (3132.18): SHA256: 5E3B3C9D5A8C633489EFFF71D7883D4E2D89C28009CA2A1D0294FB3B19A79450\\n\\nCustomers should verify the integrity of their installation packages against these values to determine whether a fixed build is in use. If the package hash does not match a known remediated value, it should be considered vulnerable.\"}], \"references\": [{\"url\": \"https://resources.genetec.com/security-advisories/vulnerability-affecting-security-center-systems-main-server-installations\"}], \"descriptions\": [{\"lang\": \"en\", \"value\": \"A high security vulnerability affecting Security Center main server installations has been identified. It could allow an attacker with local OS privileges to the main server to access the Server Admin credentials. A third party hired by Genetec found the issue. There is currently no evidence of active exploitation.\\n\\nThis vulnerability is associated with specific installation package builds rather than the product version identifier alone. Certain versions (including 5.10.4.0, 5.11.3.0, 5.12.2.0 and 5.13.3.0) were released with both vulnerable and remediated installation packages under the same version number.\\n\\nConsequently, version-based comparison alone is insufficient to determine exposure. Only installations performed using vulnerable builds are affected. Remediated builds can be distinguished using verified installation package hashes. For the complete list of fixed build hashes, refer to the security advisory section.\"}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-532\", \"description\": \"CWE-532: Insertion of Sensitive Information into Log File\"}]}], \"providerMetadata\": {\"orgId\": \"f2b06212-cb4b-41a4-9501-fa2e367495b8\", \"shortName\": \"Genetec\", \"dateUpdated\": \"2026-06-02T14:37:53.827Z\"}}}",
"cveMetadata": "{\"cveId\": \"CVE-2026-40619\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2026-06-03T03:56:05.022Z\", \"dateReserved\": \"2026-04-27T16:27:39.879Z\", \"assignerOrgId\": \"f2b06212-cb4b-41a4-9501-fa2e367495b8\", \"datePublished\": \"2026-06-02T14:37:53.827Z\", \"assignerShortName\": \"Genetec\"}",
"dataType": "CVE_RECORD",
"dataVersion": "5.2"
}
}
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…