FKIE_CVE-2005-1182
Vulnerability from fkie_nvd - Published: 2005-05-02 04:00 - Updated: 2025-04-03 01:03
Severity ?
Summary
Unknown vulnerability in Incoming Remote Command (iSeries Access for Windows Remote Command service) in IBM OS/400 R510, R520, and R530 allows attackers to cause a denial of service (IRC shutdown) via certain inputs.
References
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:ibm:os_400:r510:*:*:*:*:*:*:*",
"matchCriteriaId": "7DF9C195-FC4A-4DF4-818A-2021E986968A",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:ibm:os_400:r520:*:*:*:*:*:*:*",
"matchCriteriaId": "90930D05-EFEC-4E7A-8032-A781C0FEDE2F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:ibm:os_400:r530:*:*:*:*:*:*:*",
"matchCriteriaId": "87C7D8FC-269B-4123-BA90-784FB7ECEE94",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Unknown vulnerability in Incoming Remote Command (iSeries Access for Windows Remote Command service) in IBM OS/400 R510, R520, and R530 allows attackers to cause a denial of service (IRC shutdown) via certain inputs."
}
],
"id": "CVE-2005-1182",
"lastModified": "2025-04-03T01:03:51.193",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.0,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2005-05-02T04:00:00.000",
"references": [
{
"source": "cve@mitre.org",
"url": "http://secunia.com/advisories/14970"
},
{
"source": "cve@mitre.org",
"url": "http://www-1.ibm.com/support/docview.wss?uid=nas29afd3991f5f290b086256fdb0053b293"
},
{
"source": "cve@mitre.org",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/20612"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://secunia.com/advisories/14970"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://www-1.ibm.com/support/docview.wss?uid=nas29afd3991f5f290b086256fdb0053b293"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/20612"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…