FKIE_CVE-2011-4034
Vulnerability from fkie_nvd - Published: 2011-12-02 11:55 - Updated: 2025-04-11 00:51
Severity ?
Summary
Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to execute arbitrary code or cause a denial of service via unspecified vectors.
References
| URL | Tags | ||
|---|---|---|---|
| cret@cert.org | http://www.citect.com/index.php?option=com_content&view=article&id=1656&Itemid=1695 | Patch, Vendor Advisory | |
| cret@cert.org | http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page | Patch, Vendor Advisory | |
| cret@cert.org | http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf | Patch, US Government Resource | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.citect.com/index.php?option=com_content&view=article&id=1656&Itemid=1695 | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf | Patch, US Government Resource |
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:vijeo_historian:*:*:*:*:*:*:*:*",
"matchCriteriaId": "FA173AD2-52AF-4401-9A29-757B68168B4D",
"versionEndIncluding": "4.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:vijeo_historian:4.0:*:*:*:*:*:*:*",
"matchCriteriaId": "00E3E11B-E433-4D89-9525-8159CEC30DC0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:vijeo_historian:4.10:*:*:*:*:*:*:*",
"matchCriteriaId": "2788D1E5-206A-4AC8-AA28-65E5EE268B59",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:vijeo_historian:4.20:*:*:*:*:*:*:*",
"matchCriteriaId": "99B88BED-7F2F-4F89-9BD1-B7EDC1608531",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:citecthistorian:*:*:*:*:*:*:*:*",
"matchCriteriaId": "859A64AD-1FB2-4A7C-AE4D-26951FC050F9",
"versionEndIncluding": "4.30",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:citecthistorian:4.20:*:*:*:*:*:*:*",
"matchCriteriaId": "B491E331-B533-4E09-966E-45A3BE724C5A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:schneider-electric:citectscada_reports:*:*:*:*:*:*:*:*",
"matchCriteriaId": "106C6198-C341-4B10-8788-A8FA51F137F1",
"versionEndIncluding": "4.10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:schneider-electric:citectscada_reports:4.0:*:*:*:*:*:*:*",
"matchCriteriaId": "38765B0B-9C09-4BC0-9E50-D0C6E8969A77",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Buffer overflow in the Steema TeeChart ActiveX control, as used in Schneider Electric Vijeo Historian 4.30 and earlier, CitectHistorian 4.30 and earlier, and CitectSCADAReports 4.10 and earlier, allows remote attackers to execute arbitrary code or cause a denial of service via unspecified vectors."
},
{
"lang": "es",
"value": "Desbordamiento de b\u00fafer en el control ActiveX TeeChart Steema, tal como se utiliza en Schneider Electric Vijeo Historian v4.30 y anteriores, CitectHistorian v4.30 y anteriores, y CitectSCADAReports v4.10 y anteriores, permite a atacantes remotos ejecutar c\u00f3digo arbitrario o causar una denegaci\u00f3n de servicio a trav\u00e9s de vectores no especificados."
}
],
"id": "CVE-2011-4034",
"lastModified": "2025-04-11T00:51:21.963",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 9.3,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:N/AC:M/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
]
},
"published": "2011-12-02T11:55:05.277",
"references": [
{
"source": "cret@cert.org",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695"
},
{
"source": "cret@cert.org",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page"
},
{
"source": "cret@cert.org",
"tags": [
"Patch",
"US Government Resource"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "http://www.citect.com/index.php?option=com_content\u0026view=article\u0026id=1656\u0026Itemid=1695"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "http://www.scada.schneider-electric.com/sites/scada/en/login/historian-vulnerability.page"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"US Government Resource"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-11-307-01.pdf"
}
],
"sourceIdentifier": "cret@cert.org",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-119"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…