FKIE_CVE-2011-4878
Vulnerability from fkie_nvd - Published: 2012-02-03 20:55 - Updated: 2025-04-11 00:51
Severity ?
Summary
Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | wincc_flexible | 2004 | |
| siemens | wincc_flexible | 2005 | |
| siemens | wincc_flexible | 2007 | |
| siemens | wincc_flexible | 2008 | |
| siemens | wincc_flexible | 2008 | |
| siemens | wincc_flexible | 2008 | |
| siemens | wincc | * | |
| siemens | wincc | v11 | |
| siemens | wincc | v11 | |
| siemens | simatic_hmi_panels | comfort_panels | |
| siemens | simatic_hmi_panels | mobile_panels | |
| siemens | simatic_hmi_panels | mp | |
| siemens | simatic_hmi_panels | op | |
| siemens | simatic_hmi_panels | tp | |
| siemens | wincc_runtime_advanced | v11 | |
| siemens | wincc_flexible_runtime | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:wincc_flexible:2004:*:*:*:*:*:*:*",
"matchCriteriaId": "7D596C29-36F8-44F2-897D-FD107769E5A9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc_flexible:2005:*:*:*:*:*:*:*",
"matchCriteriaId": "2D84E29A-4BC2-4229-83C3-D9F7A641D19C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc_flexible:2007:*:*:*:*:*:*:*",
"matchCriteriaId": "9B3ADDE1-1F91-43E7-A3C3-3069916F4B23",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc_flexible:2008:*:*:*:*:*:*:*",
"matchCriteriaId": "1432EC7A-47B2-41D1-B90B-72DBB79AC266",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc_flexible:2008:sp1:*:*:*:*:*:*",
"matchCriteriaId": "1A4B1323-9AF3-424F-925A-A62F35E575E0",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc_flexible:2008:sp2:*:*:*:*:*:*",
"matchCriteriaId": "E454C72B-7804-402B-9C6A-687BF2C45D39",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:wincc:*:sp2:*:*:*:*:*:*",
"matchCriteriaId": "9FE44373-06BD-4AA0-8778-06F2A150510C",
"versionEndIncluding": "v11",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc:v11:*:*:*:*:*:*:*",
"matchCriteriaId": "18A9883B-80E1-4B2E-88DA-D2326AE3DC08",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:wincc:v11:sp1:*:*:*:*:*:*",
"matchCriteriaId": "F53FDA20-FE97-4BA3-9165-F0BD7A25FA5F",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:comfort_panels:*:*:*:*:*:*:*",
"matchCriteriaId": "DC593746-B329-43EA-8CA1-AA56AC5A3B10",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:mobile_panels:*:*:*:*:*:*:*",
"matchCriteriaId": "1DF877E8-A0D1-4444-99F2-8A3E8ED4D31B",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:mp:*:*:*:*:*:*:*",
"matchCriteriaId": "442AC914-BDD5-4D0C-9E04-88F60EE2B730",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:op:*:*:*:*:*:*:*",
"matchCriteriaId": "D9749966-1666-4F7D-90D0-17AFBB88AE83",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_hmi_panels:tp:*:*:*:*:*:*:*",
"matchCriteriaId": "9471D239-08B1-4076-82F7-2B73F4E343CE",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:wincc_runtime_advanced:v11:*:*:*:*:*:*:*",
"matchCriteriaId": "1AE3AE80-C7A2-4581-993A-536936F6D315",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:wincc_flexible_runtime:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6F785262-BBFB-4A0C-A7DC-97F5D6B94BB0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Directory traversal vulnerability in miniweb.exe in the HMI web server in Siemens WinCC flexible 2004, 2005, 2007, and 2008 before SP3; WinCC V11 (aka TIA portal) before SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime allows remote attackers to read arbitrary files via a ..%5c (dot dot backslash) in a URI."
},
{
"lang": "es",
"value": "Vulnerabilidad de salto de directorio en miniweb.exe de servidor web HMI de Siemens WinCC flexible 2004, 2005, 2007, y 2008 anteriores a SP3; WinCC V11 (TIA portal) anteriores a SP2 Update 1; the TP, OP, MP, Comfort Panels, and Mobile Panels SIMATIC HMI panels; WinCC V11 Runtime Advanced; and WinCC flexible Runtime permite a atacantes remotos leer archivos arbitrarios a trav\u00e9s de los caracteres ..%5c (punto punto barra invertida) en una URI."
}
],
"id": "CVE-2011-4878",
"lastModified": "2025-04-11T00:51:21.963",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 7.8,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:C/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
]
},
"published": "2012-02-03T20:55:02.030",
"references": [
{
"source": "cret@cert.org",
"url": "http://aluigi.org/adv/winccflex_1-adv.txt"
},
{
"source": "cret@cert.org",
"url": "http://www.exploit-db.com/exploits/18166"
},
{
"source": "cret@cert.org",
"url": "http://www.osvdb.org/77383"
},
{
"source": "cret@cert.org",
"tags": [
"Vendor Advisory"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
},
{
"source": "cret@cert.org",
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
},
{
"source": "cret@cert.org",
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
},
{
"source": "cret@cert.org",
"tags": [
"US Government Resource"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
},
{
"source": "cret@cert.org",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71452"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://aluigi.org/adv/winccflex_1-adv.txt"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://www.exploit-db.com/exploits/18166"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://www.osvdb.org/77383"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-345442.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://www.us-cert.gov/control_systems/pdf/ICS-ALERT-11-332-02A.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"US Government Resource"
],
"url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-030-01.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://exchange.xforce.ibmcloud.com/vulnerabilities/71452"
}
],
"sourceIdentifier": "cret@cert.org",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…