FKIE_CVE-2012-1802

Vulnerability from fkie_nvd - Published: 2012-04-18 10:33 - Updated: 2026-06-16 23:40
Severity
Summary
Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL.

{
  "affected": [
    {
      "affectedData": [
        {
          "product": "n/a",
          "vendor": "n/a",
          "versions": [
            {
              "status": "affected",
              "version": "n/a"
            }
          ]
        }
      ],
      "source": "cret@cert.org"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FB47C02A-0FD8-47A2-93F8-310A5E05E19F",
              "versionEndIncluding": "3.7.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:1.2.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "6212D6C3-A68D-41BA-929A-943A157B3BA7",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.1.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "56338A9A-C59D-47D3-9AB4-18C53A75EDD5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "801D7741-8EBB-4A68-A77C-E26C304EB988",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.3.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "EF4AB664-29DD-46F0-B136-8BD458430BD4",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:2.3.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "DB8720F3-21D3-40C1-98A8-90E2EF6BBA52",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.0.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "FFF99DC1-34B7-4AAA-BC33-5763B56EEA1B",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.0.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "629D65C2-0D61-48BD-9C73-7794AC061756",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.3.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "DDD5708A-0105-4129-B5A6-DAF0247ABE1F",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x414-3e_firmware:3.4.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "B349A4F6-1FB0-433B-B512-883E580CFB27",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x414-3e:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "6645288F-F688-442A-8C56-17536BFAD4BE",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x308-2m_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "EC42F509-F58D-4A65-9C31-26F0C7319076",
              "versionEndIncluding": "3.7.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x308-2m_firmware:3.1.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "4020E0F4-E92A-442D-A703-CA8840B8D944",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x308-2m_firmware:3.5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "58E635A6-1AFF-4A34-87F3-F68571032448",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x308-2m_firmware:3.5.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB1B5735-D3C0-445C-B7D5-A3099D1CE152",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x308-2m:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC54911E-C432-48FA-9551-9644422FFE14",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x-300eec_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "6F13D012-86FA-4A41-8D18-94942A270DAA",
              "versionEndIncluding": "3.7.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x-300eec_firmware:3.5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "BB16E154-1E59-438F-9895-47260FDD7230",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x-300eec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2F32466-A411-4D69-864A-4434D3D5DB54",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:scalance_xr-300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "FF530C3C-A126-4F6A-8010-E93352800598",
              "versionEndIncluding": "3.7.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_xr-300_firmware:3.1.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "AE3F5ED9-F357-430C-B277-B7EC0715A391",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_xr-300_firmware:3.5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "61FF9CF2-14CD-49BF-AC0B-0D2E0EDCF79F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_xr-300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "889CF2C0-EE6C-447F-85F1-005730EAD232",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x-300_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "F2000A16-E8A2-4E8E-A90F-4E0F62F3993C",
              "versionEndIncluding": "3.7.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x-300_firmware:2.2.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "AF93BD72-2893-436D-A514-3C463C1AA428",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x-300_firmware:2.3.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "59323828-6A3A-48CD-B98C-64CD65829471",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x-300_firmware:3.0.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "C8C53B2B-BFFC-47D1-B935-FF85F5A4D3F1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x-300_firmware:3.3.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "054C0618-5CA9-43E4-A557-0064B8BB5B63",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x-300_firmware:3.5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "6D5DF242-8FD0-467C-84D1-5207CC15D2D2",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:scalance_x-300_firmware:3.5.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "B16E873A-5D79-43B8-BB64-66B8079CFCC4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:scalance_x-300:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B2D0AB50-6F0B-4232-8C8E-1647410D362D",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Buffer overflow in the embedded web server on the Siemens Scalance X Industrial Ethernet switch X414-3E before 3.7.1, X308-2M before 3.7.2, X-300EEC before 3.7.2, XR-300 before 3.7.2, and X-300 before 3.7.2 allows remote attackers to cause a denial of service (device reboot) or possibly execute arbitrary code via a malformed URL."
    },
    {
      "lang": "es",
      "value": "Desbordamiento de b\u00fafer en el servidor web integrado en el conmutador ethernet industrial Siemens Scalance X X414-3E antes de v3.7.1, X308-2M antes de v3.7.2, X-300EEC antes de v3.7.2, XR-300 antes de v3.7.2, y X-300 antes de v3.7.2 permite a atacantes remotos causar una denegaci\u00f3n de servicio (reinicio del dispositivo) o posiblemente ejecutar c\u00f3digo arbitrario a trav\u00e9s de una direcci\u00f3n URL incorrecta."
    }
  ],
  "id": "CVE-2012-1802",
  "lastModified": "2026-06-16T23:40:19.980",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "HIGH",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "COMPLETE",
          "baseScore": 7.8,
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
          "version": "2.0"
        },
        "exploitabilityScore": 10.0,
        "impactScore": 6.9,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ]
  },
  "published": "2012-04-18T10:33:35.450",
  "references": [
    {
      "source": "cret@cert.org",
      "url": "http://osvdb.org/81032"
    },
    {
      "source": "cret@cert.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf"
    },
    {
      "source": "cret@cert.org",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://osvdb.org/81032"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.siemens.com/corporate-technology/pool/de/forschungsfelder/siemens_security_advisory_ssa-130874.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "US Government Resource"
      ],
      "url": "http://www.us-cert.gov/control_systems/pdf/ICSA-12-102-04.pdf"
    }
  ],
  "sourceIdentifier": "cret@cert.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-119"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…