FKIE_CVE-2013-1079

Vulnerability from fkie_nvd - Published: 2013-03-29 16:09 - Updated: 2025-04-11 00:51
Severity ?
Summary
Directory traversal vulnerability in the ISCreateObject method in an ActiveX control in InstallShield\ISProxy.dll in AdminStudio in Novell ZENworks Configuration Management (ZCM) 10.3 through 11.2 allows remote attackers to execute arbitrary local DLL files via a crafted web page that also calls the Initialize method.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:novell:zenworks_configuration_management:10.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "0ABC25E5-76CD-469B-879A-B1F7109D0181",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:novell:zenworks_configuration_management:10.3.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "556F4B13-4C98-41D6-A2A4-138780C206CD",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:novell:zenworks_configuration_management:10.3.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F4C1F2D-D479-4353-8E95-A1326783CEBB",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:novell:zenworks_configuration_management:10.3.3:*:*:*:*:*:*:*",
              "matchCriteriaId": "44E12A11-E11B-4330-A94E-7F40BE3ECFD3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:novell:zenworks_configuration_management:11:*:*:*:*:*:*:*",
              "matchCriteriaId": "98942F6C-330F-459A-B2B4-72572DB4070E",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:novell:zenworks_configuration_management:11.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "F5A92B0C-7256-45F0-8E0C-ADFEF36CF43D",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:novell:zenworks_configuration_management:11.1a:*:*:*:*:*:*:*",
              "matchCriteriaId": "2446CA9A-9908-4270-9F4B-119835588D99",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:novell:zenworks_configuration_management:11.2:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C0BAB94-6521-4B57-9E56-A57BA5E20C24",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Directory traversal vulnerability in the ISCreateObject method in an ActiveX control in InstallShield\\ISProxy.dll in AdminStudio in Novell ZENworks Configuration Management (ZCM) 10.3 through 11.2 allows remote attackers to execute arbitrary local DLL files via a crafted web page that also calls the Initialize method."
    },
    {
      "lang": "es",
      "value": "Vulnerabilidad de salto de directorio en el m\u00e9todo ISCreateObject en un control ActiveX en InstallShield\\ISProxy.dll en AdminStudio in Novell ZENworks Configuration Management (ZCM) v10.3 hasta v11.2 permite a atacantes remotos ejecutar archivos DLL locales a trav\u00e9s de una p\u00e1gina web manipulada para que tambi\u00e9n llame al m\u00e9todo Initialize."
    }
  ],
  "id": "CVE-2013-1079",
  "lastModified": "2025-04-11T00:51:21.963",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ]
  },
  "published": "2013-03-29T16:09:04.003",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.novell.com/support/kb/doc.php?id=7011811"
    },
    {
      "source": "cve@mitre.org",
      "url": "http://www.zerodayinitiative.com/advisories/ZDI-13-048/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "http://www.novell.com/support/kb/doc.php?id=7011811"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "http://www.zerodayinitiative.com/advisories/ZDI-13-048/"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-22"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…