FKIE_CVE-2017-17330
Vulnerability from fkie_nvd - Published: 2018-03-09 17:29 - Updated: 2024-11-21 03:17
Severity ?
Summary
Huawei AR3200 V200R005C32; V200R006C10; V200R006C11; V200R007C00; V200R007C01; V200R007C02; V200R008C00; V200R008C10; V200R008C20; V200R008C30; NGFW Module V500R001C00; V500R001C20; V500R002C00 have a memory leak vulnerability. The software does not release allocated memory properly when parse XML element data. An authenticated attacker could upload a crafted XML file, successful exploit could cause the system service abnormal since run out of memory.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| huawei | ar3200_firmware | v200r005c32 | |
| huawei | ar3200_firmware | v200r006c10 | |
| huawei | ar3200_firmware | v200r006c11 | |
| huawei | ar3200_firmware | v200r007c00 | |
| huawei | ar3200_firmware | v200r007c01 | |
| huawei | ar3200_firmware | v200r007c02 | |
| huawei | ar3200_firmware | v200r008c00 | |
| huawei | ar3200_firmware | v200r008c10 | |
| huawei | ar3200_firmware | v200r008c20 | |
| huawei | ar3200_firmware | v200r008c30 | |
| huawei | ar3200 | - | |
| huawei | ngfw_module_firmware | v500r001c00 | |
| huawei | ngfw_module_firmware | v500r001c20 | |
| huawei | ngfw_module_firmware | v500r002c00 | |
| huawei | ngfw_module | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:huawei:ar3200_firmware:v200r005c32:*:*:*:*:*:*:*",
"matchCriteriaId": "7FE26EE9-2331-4D72-96CF-635A0A4EBE3E",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:huawei:ar3200_firmware:v200r006c10:*:*:*:*:*:*:*",
"matchCriteriaId": "DB9A3444-A485-4B87-B910-F3DA5C8E5D74",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:huawei:ar3200_firmware:v200r006c11:*:*:*:*:*:*:*",
"matchCriteriaId": "B8BE6310-A42C-4BB3-BB02-7CE6F4FF340D",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:huawei:ar3200_firmware:v200r007c00:*:*:*:*:*:*:*",
"matchCriteriaId": "9752658E-3CF5-4D9E-98FB-D15FD892479C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:huawei:ar3200_firmware:v200r007c01:*:*:*:*:*:*:*",
"matchCriteriaId": "0595B3AA-8911-44AF-996B-2F431517FBED",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:huawei:ar3200_firmware:v200r007c02:*:*:*:*:*:*:*",
"matchCriteriaId": "FC727A7A-CF3D-4DC9-9083-A0CE8ED886A8",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:huawei:ar3200_firmware:v200r008c00:*:*:*:*:*:*:*",
"matchCriteriaId": "1A842B77-C902-4B20-A171-3F98C75E6160",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:huawei:ar3200_firmware:v200r008c10:*:*:*:*:*:*:*",
"matchCriteriaId": "AC61DFB2-E24C-4148-892E-A14F1EC3F9CA",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:huawei:ar3200_firmware:v200r008c20:*:*:*:*:*:*:*",
"matchCriteriaId": "A8D0F6C6-5A87-482B-8B2A-693AC7736CB9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:huawei:ar3200_firmware:v200r008c30:*:*:*:*:*:*:*",
"matchCriteriaId": "B01969DE-DC37-4F2F-BB9B-5242810A8317",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:huawei:ar3200:-:*:*:*:*:*:*:*",
"matchCriteriaId": "9309E1AA-0C4E-422C-9307-A8DD0AE5D576",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:huawei:ngfw_module_firmware:v500r001c00:*:*:*:*:*:*:*",
"matchCriteriaId": "80411236-6B22-4937-87F3-E06C991B14D6",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:huawei:ngfw_module_firmware:v500r001c20:*:*:*:*:*:*:*",
"matchCriteriaId": "1A8E1096-F070-4CE9-B2B4-6368890706A9",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:huawei:ngfw_module_firmware:v500r002c00:*:*:*:*:*:*:*",
"matchCriteriaId": "F46A81BE-C125-4CAE-8EE1-23177FE0C21E",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:huawei:ngfw_module:-:*:*:*:*:*:*:*",
"matchCriteriaId": "547D4A9A-6B57-4BBA-9FFE-CF50B9AC5DF4",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Huawei AR3200 V200R005C32; V200R006C10; V200R006C11; V200R007C00; V200R007C01; V200R007C02; V200R008C00; V200R008C10; V200R008C20; V200R008C30; NGFW Module V500R001C00; V500R001C20; V500R002C00 have a memory leak vulnerability. The software does not release allocated memory properly when parse XML element data. An authenticated attacker could upload a crafted XML file, successful exploit could cause the system service abnormal since run out of memory."
},
{
"lang": "es",
"value": "Huawei AR3200 V200R005C32; V200R006C10; V200R006C11; V200R007C00; V200R007C01; V200R007C02; V200R008C00; V200R008C10; V200R008C20; V200R008C30; NGFW Module V500R001C00; V500R001C20 y V500R002C00 tienen una vulnerabilidad de filtrado de memoria. El software no libera la memoria asignada correctamente al analizar los datos de elementos XML. Un atacante autenticado podr\u00eda subir un archivo XML manipulado, por lo que la explotaci\u00f3n exitosa de esta vulnerabilidad podr\u00eda provocar que los servicios del sistema funcionen de manera incorrecta, ya que se quedar\u00edan sin memoria."
}
],
"id": "CVE-2017-17330",
"lastModified": "2024-11-21T03:17:51.020",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 2.1,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:L/AC:L/Au:N/C:N/I:N/A:P",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "LOW",
"baseScore": 3.3,
"baseSeverity": "LOW",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:N/I:N/A:L",
"version": "3.0"
},
"exploitabilityScore": 1.8,
"impactScore": 1.4,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-03-09T17:29:02.330",
"references": [
{
"source": "psirt@huawei.com",
"tags": [
"Vendor Advisory"
],
"url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20171206-04-xml-en"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "http://www.huawei.com/en/psirt/security-advisories/huawei-sa-20171206-04-xml-en"
}
],
"sourceIdentifier": "psirt@huawei.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-772"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…