FKIE_CVE-2018-12172
Vulnerability from fkie_nvd - Published: 2018-10-10 18:29 - Updated: 2024-11-21 03:44
Severity ?
Summary
Improper password hashing in firmware in Intel Server Board (S7200AP,S7200APR) and Intel Compute Module (HNS7200AP, HNS7200AP) may allow a privileged user to potentially disclose firmware passwords via local access.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| intel | s7200ap_firmware | r01.03.0018 | |
| intel | s7200ap | - | |
| intel | hns7200ap_firmware | r01.03.0018 | |
| intel | hns7200ap | - | |
| intel | s7200apr_firmware | r01.03.0018 | |
| intel | s7200apr | - | |
| intel | hns7200apr_firmware | r01.03.0018 | |
| intel | hns7200apr | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:intel:s7200ap_firmware:r01.03.0018:*:*:*:*:*:*:*",
"matchCriteriaId": "7E769961-87C3-4B7B-81E8-2855B8FA9F2D",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:intel:s7200ap:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BF802F5C-8F39-4FC0-8C15-6B8545BDF97F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:intel:hns7200ap_firmware:r01.03.0018:*:*:*:*:*:*:*",
"matchCriteriaId": "7CEC71FA-3735-477A-8D32-3FD81032F224",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:intel:hns7200ap:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AE3E826A-6B5B-4445-9D09-0D3C65276259",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:intel:s7200apr_firmware:r01.03.0018:*:*:*:*:*:*:*",
"matchCriteriaId": "0EBBD550-A13E-41C0-9B07-EE0375D1640C",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:intel:s7200apr:-:*:*:*:*:*:*:*",
"matchCriteriaId": "F73E6B49-70E1-4FC0-9349-9EAFA9B622BA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:intel:hns7200apr_firmware:r01.03.0018:*:*:*:*:*:*:*",
"matchCriteriaId": "5C5AE7A3-0455-45CA-AB89-A1C5E6714112",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:intel:hns7200apr:-:*:*:*:*:*:*:*",
"matchCriteriaId": "254CB73B-6A91-408F-A3C9-D3259BC2EF9F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Improper password hashing in firmware in Intel Server Board (S7200AP,S7200APR) and Intel Compute Module (HNS7200AP, HNS7200AP) may allow a privileged user to potentially disclose firmware passwords via local access."
},
{
"lang": "es",
"value": "Hasheo de contrase\u00f1as incorrecto en el firmware en Intel Server Board (S7200AP, S7200APR) e Intel Compute Module (HNS7200AP, HNS7200AP) podr\u00eda permitir que un usuario privilegiado divulgue contrase\u00f1as del firmware mediante acceso local."
}
],
"id": "CVE-2018-12172",
"lastModified": "2024-11-21T03:44:41.647",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 2.1,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV30": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "NONE",
"baseScore": 5.5,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.0/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
"version": "3.0"
},
"exploitabilityScore": 1.8,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2018-10-10T18:29:04.280",
"references": [
{
"source": "secure@intel.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00138.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.intel.com/content/www/us/en/security-center/advisory/intel-sa-00138.html"
}
],
"sourceIdentifier": "secure@intel.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…