FKIE_CVE-2018-18630

Vulnerability from fkie_nvd - Published: 2019-09-06 17:15 - Updated: 2024-11-21 03:56
Summary
A vulnerability was found in McKesson Cardiology product 13.x and 14.x. Insecure file permissions in the default installation may allow an attacker with local system access to execute unauthorized arbitrary code.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mckesson:horizon_cardiology_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A821C13B-5C49-45F6-A627-A002B4196708",
              "versionEndIncluding": "12.2",
              "versionStartIncluding": "12.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:mckesson:horizon_cardiology_firmware:11.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "070A853B-9367-49CA-8323-4F3179F91E97",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mckesson:horizon_cardiology:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "12B71733-3536-4393-8699-5224FA4BBCBB",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:mckesson:cardiology_firmware:13.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "93A43EC6-75AA-41D5-9147-C51A08493D9C",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:mckesson:cardiology_firmware:14.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "11A6730B-A685-4B40-AB12-0EC2ABE6D657",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:mckesson:cardiology:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "95517334-C76C-47F2-A979-40D046DBF07F",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:changehealthcare:cardiology_firmware:14.1.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "887AC5DC-F002-47A2-A399-6C18F59A3381",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:changehealthcare:cardiology:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5DBC82FA-FC4B-4C5E-8BCD-60D353B37E22",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability was found in McKesson Cardiology product 13.x and 14.x. Insecure file permissions in the default installation may allow an attacker with local system access to execute unauthorized arbitrary code."
    },
    {
      "lang": "es",
      "value": "Se encontr\u00f3 una vulnerabilidad en producto McKesson Cardiology versiones 13.x y 14.x. Permisos de archivos no seguros en la instalaci\u00f3n predeterminada pueden permitir a un atacante con acceso al sistema local ejecutar c\u00f3digo arbitrario no autorizado."
    }
  ],
  "id": "CVE-2018-18630",
  "lastModified": "2024-11-21T03:56:16.020",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "LOW",
          "accessVector": "LOCAL",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 4.6,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": false
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2019-09-06T17:15:11.183",
  "references": [
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.hipaajournal.com/code-execution-vulnerability-identified-in-change-healthcare-cardiology-devices/"
    },
    {
      "source": "cve@mitre.org",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsma-19-241-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.hipaajournal.com/code-execution-vulnerability-identified-in-change-healthcare-cardiology-devices/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory",
        "US Government Resource"
      ],
      "url": "https://www.us-cert.gov/ics/advisories/icsma-19-241-01"
    }
  ],
  "sourceIdentifier": "cve@mitre.org",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-732"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…