FKIE_CVE-2019-14928
Vulnerability from fkie_nvd - Published: 2019-10-28 13:15 - Updated: 2024-11-21 04:27
Severity ?
Summary
An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A number of stored cross-site script (XSS) vulnerabilities allow an attacker to inject malicious code directly into the application. An example input variable vulnerable to stored XSS is SerialInitialModemString in the index.php page.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://www.mogozobo.com/ | Third Party Advisory | |
| cve@mitre.org | https://www.mogozobo.com/?p=3593 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.mogozobo.com/ | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.mogozobo.com/?p=3593 | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| mitsubishielectric | smartrtu_firmware | * | |
| mitsubishielectric | smartrtu | - | |
| inea | me-rtu_firmware | * | |
| inea | me-rtu | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:mitsubishielectric:smartrtu_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "62D6CAA7-11E1-4DF2-A9BD-EC71AE7CD166",
"versionEndIncluding": "2.02",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:mitsubishielectric:smartrtu:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1EF90DA0-55C7-4765-9DEE-80145752961D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:inea:me-rtu_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "DDC6C049-B15B-4FC2-9DDF-915381E6D114",
"versionEndIncluding": "3.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:inea:me-rtu:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FD7F8299-4A9C-4B93-A35A-68C6D43855CC",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue was discovered on Mitsubishi Electric Europe B.V. ME-RTU devices through 2.02 and INEA ME-RTU devices through 3.0. A number of stored cross-site script (XSS) vulnerabilities allow an attacker to inject malicious code directly into the application. An example input variable vulnerable to stored XSS is SerialInitialModemString in the index.php page."
},
{
"lang": "es",
"value": "Se descubri\u00f3 un problema en los dispositivos Mitsubishi Electric ME-RTU versiones hasta la veris\u00f3n 2.02 y los dispositivos INEA ME-RTU versiones hasta la versi\u00f3n 3.0. Una serie de vulnerabilidades de tipo cross-site script (XSS) almacenado permiten a un atacante inyectar c\u00f3digo malicioso directamente en la aplicaci\u00f3n. Un ejemplo de variable de entrada vulnerable a XSS almacenado es SerialInitialModemString en la p\u00e1gina del archivo index.php."
}
],
"id": "CVE-2019-14928",
"lastModified": "2024-11-21T04:27:42.147",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "LOW",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "NONE",
"baseScore": 3.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:N/I:P/A:N",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 5.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "LOW",
"scope": "CHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:C/C:L/I:L/A:N",
"version": "3.1"
},
"exploitabilityScore": 2.3,
"impactScore": 2.7,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2019-10-28T13:15:10.837",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://www.mogozobo.com/"
},
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.mogozobo.com/?p=3593"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://www.mogozobo.com/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.mogozobo.com/?p=3593"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-79"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…