FKIE_CVE-2019-19506
Vulnerability from fkie_nvd - Published: 2020-06-25 20:15 - Updated: 2024-11-21 04:34
Severity ?
Summary
Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 is vulnerable to a denial of service, caused by an error in the "homeplugd" process. By sending a specially crafted UDP packet, an attacker could exploit this vulnerability to cause the device to reboot.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://securityintelligence.com/posts/vulnerable-powerline-extenders-underline-lax-iot-security/ | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://securityintelligence.com/posts/vulnerable-powerline-extenders-underline-lax-iot-security/ | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tendacn | pa6_firmware | 1.0.1.21 | |
| tendacn | pa6 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tendacn:pa6_firmware:1.0.1.21:*:*:*:*:*:*:*",
"matchCriteriaId": "F6091063-6B03-4B7F-B425-B4C37B057A74",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tendacn:pa6:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FC86310B-B452-4CEF-986C-2BB4CC535A0A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Tenda PA6 Wi-Fi Powerline extender 1.0.1.21 is vulnerable to a denial of service, caused by an error in the \"homeplugd\" process. By sending a specially crafted UDP packet, an attacker could exploit this vulnerability to cause the device to reboot."
},
{
"lang": "es",
"value": "El extensor Tenda PA6 Wi-Fi Powerline versi\u00f3n 1.0.1.21, es vulnerable a una denegaci\u00f3n de servicio, causada por un error en el proceso \"homeplugd\". Mediante el env\u00edo de un paquete UDP especialmente dise\u00f1ado, un atacante podr\u00eda aprovechar esta vulnerabilidad para hacer que el dispositivo se reinicie"
}
],
"id": "CVE-2019-19506",
"lastModified": "2024-11-21T04:34:51.313",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.8,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-06-25T20:15:11.053",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://securityintelligence.com/posts/vulnerable-powerline-extenders-underline-lax-iot-security/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://securityintelligence.com/posts/vulnerable-powerline-extenders-underline-lax-iot-security/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-835"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…