fkie_cve-2019-20666
Vulnerability from fkie_nvd
Published
2020-04-15 20:15
Modified
2024-11-21 04:39
Summary
Certain NETGEAR devices are affected by stored XSS. This affects RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, and RBK50 before 2.3.5.30.
Impacted products



{
   configurations: [
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:netgear:rbr50_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "094B04D5-9063-4D7A-B367-E1F2688B3667",
                     versionEndExcluding: "2.3.5.30",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:netgear:rbr50:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "B2CAEA32-6934-4743-9E6B-22D52AC5E7F8",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:netgear:rbs50_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "C489444C-6C19-4A52-AF66-A1D48ADC4F26",
                     versionEndExcluding: "2.3.5.30",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:netgear:rbs50:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "3BCFD959-D522-4FA0-AD01-2937DAEE1EDF",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
      {
         nodes: [
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:o:netgear:rbk50_firmware:*:*:*:*:*:*:*:*",
                     matchCriteriaId: "B7ED1541-DE7D-4A4C-B8D1-CB42E52E3DBE",
                     versionEndExcluding: "2.3.5.30",
                     vulnerable: true,
                  },
               ],
               negate: false,
               operator: "OR",
            },
            {
               cpeMatch: [
                  {
                     criteria: "cpe:2.3:h:netgear:rbk50:-:*:*:*:*:*:*:*",
                     matchCriteriaId: "8BA66D07-D017-49D6-8E72-5C48E940DE1B",
                     vulnerable: false,
                  },
               ],
               negate: false,
               operator: "OR",
            },
         ],
         operator: "AND",
      },
   ],
   cveTags: [],
   descriptions: [
      {
         lang: "en",
         value: "Certain NETGEAR devices are affected by stored XSS. This affects RBR50 before 2.3.5.30, RBS50 before 2.3.5.30, and RBK50 before 2.3.5.30.",
      },
      {
         lang: "es",
         value: "Determinados dispositivos NETGEAR están afectados por una vulnerabilidad de tipo XSS almacenado. Esto afecta a RBR50 versiones anteriores a 2.3.5.30, RBS50 versiones anteriores a 2.3.5.30 y RBK50 versiones anteriores a 2.3.5.30.",
      },
   ],
   id: "CVE-2019-20666",
   lastModified: "2024-11-21T04:39:00.623",
   metrics: {
      cvssMetricV2: [
         {
            acInsufInfo: false,
            baseSeverity: "LOW",
            cvssData: {
               accessComplexity: "MEDIUM",
               accessVector: "NETWORK",
               authentication: "SINGLE",
               availabilityImpact: "NONE",
               baseScore: 3.5,
               confidentialityImpact: "NONE",
               integrityImpact: "PARTIAL",
               vectorString: "AV:N/AC:M/Au:S/C:N/I:P/A:N",
               version: "2.0",
            },
            exploitabilityScore: 6.8,
            impactScore: 2.9,
            obtainAllPrivilege: false,
            obtainOtherPrivilege: false,
            obtainUserPrivilege: false,
            source: "nvd@nist.gov",
            type: "Primary",
            userInteractionRequired: true,
         },
      ],
      cvssMetricV30: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "LOCAL",
               availabilityImpact: "NONE",
               baseScore: 6,
               baseSeverity: "MEDIUM",
               confidentialityImpact: "HIGH",
               integrityImpact: "HIGH",
               privilegesRequired: "HIGH",
               scope: "UNCHANGED",
               userInteraction: "NONE",
               vectorString: "CVSS:3.0/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:N",
               version: "3.0",
            },
            exploitabilityScore: 0.8,
            impactScore: 5.2,
            source: "cve@mitre.org",
            type: "Secondary",
         },
      ],
      cvssMetricV31: [
         {
            cvssData: {
               attackComplexity: "LOW",
               attackVector: "NETWORK",
               availabilityImpact: "NONE",
               baseScore: 4.8,
               baseSeverity: "MEDIUM",
               confidentialityImpact: "LOW",
               integrityImpact: "LOW",
               privilegesRequired: "HIGH",
               scope: "CHANGED",
               userInteraction: "REQUIRED",
               vectorString: "CVSS:3.1/AV:N/AC:L/PR:H/UI:R/S:C/C:L/I:L/A:N",
               version: "3.1",
            },
            exploitabilityScore: 1.7,
            impactScore: 2.7,
            source: "nvd@nist.gov",
            type: "Primary",
         },
      ],
   },
   published: "2020-04-15T20:15:13.693",
   references: [
      {
         source: "cve@mitre.org",
         tags: [
            "Vendor Advisory",
         ],
         url: "https://kb.netgear.com/000061473/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-WiFi-Systems-PSV-2018-0555",
      },
      {
         source: "af854a3a-2127-422b-91ae-364da2661108",
         tags: [
            "Vendor Advisory",
         ],
         url: "https://kb.netgear.com/000061473/Security-Advisory-for-Stored-Cross-Site-Scripting-on-Some-WiFi-Systems-PSV-2018-0555",
      },
   ],
   sourceIdentifier: "cve@mitre.org",
   vulnStatus: "Modified",
   weaknesses: [
      {
         description: [
            {
               lang: "en",
               value: "CWE-79",
            },
         ],
         source: "nvd@nist.gov",
         type: "Primary",
      },
   ],
}


Log in or create an account to share your comment.

Security Advisory comment format.

This schema specifies the format of a comment related to a security advisory.

UUIDv4 of the comment
UUIDv4 of the Vulnerability-Lookup instance
When the comment was created originally
When the comment was last updated
Title of the comment
Description of the comment
The identifier of the vulnerability (CVE ID, GHSA-ID, PYSEC ID, etc.).



Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
  • Confirmed: The vulnerability is confirmed from an analyst perspective.
  • Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
  • Patched: This vulnerability was successfully patched by the user reporting the sighting.
  • Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
  • Not confirmed: The user expresses doubt about the veracity of the vulnerability.
  • Not patched: This vulnerability was not successfully patched by the user reporting the sighting.