FKIE_CVE-2020-26922
Vulnerability from fkie_nvd - Published: 2020-10-09 07:15 - Updated: 2024-11-21 05:20
Severity ?
6.4 (Medium) - CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H
6.7 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
6.7 (Medium) - CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Summary
Certain NETGEAR devices are affected by command injection by an authenticated user. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | wc7500_firmware | * | |
| netgear | wc7500 | - | |
| netgear | wc7600_firmware | * | |
| netgear | wc7600 | - | |
| netgear | wc7600v2_firmware | * | |
| netgear | wc7600v2 | - | |
| netgear | wc9500_firmware | * | |
| netgear | wc9500 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wc7500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7C7EBAEB-4D71-4F10-8B42-F5C844E1B71E",
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wc7500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EB22B065-8EC8-4DA7-984A-CCB6919AF8F3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wc7600_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "93AD60DB-0EBB-467B-AD0C-5C107DCC446F",
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wc7600:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FF16A53E-FFFD-4F11-831A-82BB76675CBD",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wc7600v2_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "470918A5-9FE0-4F63-8455-5527CF138F54",
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wc7600v2:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4C8BB1F1-A12D-43CC-A6D0-9633E99D746B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:wc9500_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "23E6496E-07CD-4191-B117-530D063514EE",
"versionEndExcluding": "6.5.5.24",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:wc9500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "113D0DF6-C719-4A43-80B2-463EC4323009",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by command injection by an authenticated user. This affects WC7500 before 6.5.5.24, WC7600 before 6.5.5.24, WC7600v2 before 6.5.5.24, and WC9500 before 6.5.5.24."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR, est\u00e1n afectados por una inyecci\u00f3n de comandos por parte de un usuario autenticado.\u0026#xa0;Esto afecta a WC7500 versiones anteriores a 6.5.5.24, WC7600 versiones anteriores a 6.5.5.24, WC7600v2 versiones anteriores a 6.5.5.24 y WC9500 versiones anteriores a 6.5.5.24"
}
],
"id": "CVE-2020-26922",
"lastModified": "2024-11-21T05:20:30.220",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 4.6,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:L/AC:L/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:H/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.5,
"impactScore": 5.9,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 6.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 0.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-10-09T07:15:17.857",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000062330/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2020-0139"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000062330/Security-Advisory-for-Post-Authentication-Command-Injection-on-Some-Wireless-Controllers-PSV-2020-0139"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…