Summary
Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects JGS516PE before 2.6.0.48, JGS524Ev2 before 2.6.0.48, JGS524PE before 2.6.0.48, and GS116Ev2 before 2.6.0.48. A TFTP server was found to be active by default. It allows remote authenticated users to update the switch firmware.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| netgear | jgs516pe_firmware | * | |
| netgear | jgs516pe | - | |
| netgear | jgs524e_firmware | * | |
| netgear | jgs524e | v2 | |
| netgear | jgs524pe_firmware | * | |
| netgear | jgs524pe | - | |
| netgear | gs116e_firmware | * | |
| netgear | gs116e | v2 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:jgs516pe_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "83FA56EB-35CD-4A58-8019-C4597AAC0104",
"versionEndExcluding": "2.6.0.48",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:jgs516pe:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DCBC0DAB-226E-4C95-9818-7758D37EFD10",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:jgs524e_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "19D0AC3E-87B5-435A-B203-E9759A4A5396",
"versionEndExcluding": "2.6.0.48",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:jgs524e:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "CFF899BD-AA1E-4C47-BCFD-5E32F75F538A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:jgs524pe_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "62D7F6C3-8104-4C7D-AE9D-8C96D40221A3",
"versionEndExcluding": "2.6.0.48",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:jgs524pe:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D4A32288-19B5-4A8F-B883-FCC326B7032D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:netgear:gs116e_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "9CCEFE31-BAA8-4791-BB66-27D341EAE6C7",
"versionEndExcluding": "2.6.0.48",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:netgear:gs116e:v2:*:*:*:*:*:*:*",
"matchCriteriaId": "6DA5EF92-9B28-4C81-8A95-C5BCEC19591A",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Certain NETGEAR devices are affected by incorrect configuration of security settings. This affects JGS516PE before 2.6.0.48, JGS524Ev2 before 2.6.0.48, JGS524PE before 2.6.0.48, and GS116Ev2 before 2.6.0.48. A TFTP server was found to be active by default. It allows remote authenticated users to update the switch firmware."
},
{
"lang": "es",
"value": "Determinados dispositivos NETGEAR est\u00e1n afectados por una configuraci\u00f3n incorrecta de los ajustes de seguridad.\u0026#xa0;Esto afecta a JGS516PE versiones anteriores a 2.6.0.48, JGS524Ev2 versiones anteriores a 2.6.0.48, JGS524PE versiones anteriores a 2.6.0.48 y GS116Ev2 versiones anteriores a 2.6.0.48. Se encontr\u00f3 un servidor TFTP activo por defecto. Permite a los usuarios remotos autentificados actualizar el firmware del switch"
}
],
"id": "CVE-2020-35801",
"lastModified": "2024-11-21T05:28:08.977",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.5,
"confidentialityImpact": "NONE",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:N/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 4.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "LOW",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:L/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.5,
"source": "cve@mitre.org",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:L/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.1,
"impactScore": 5.2,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-12-30T00:15:14.457",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000062635/Security-Advisory-for-Security-Misconfiguration-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0376"
},
{
"source": "cve@mitre.org",
"tags": [
"Not Applicable"
],
"url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://kb.netgear.com/000062635/Security-Advisory-for-Security-Misconfiguration-on-Some-Smart-Managed-Plus-Switches-PSV-2020-0376"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Not Applicable"
],
"url": "https://research.nccgroup.com/2021/03/08/technical-advisory-multiple-vulnerabilities-in-netgear-prosafe-plus-jgs516pe-gs116ev2-switches/"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-noinfo"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…