FKIE_CVE-2020-6651
Vulnerability from fkie_nvd - Published: 2020-05-07 16:15 - Updated: 2024-11-21 05:36
Severity ?
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
7.3 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H
Summary
Improper Input Validation in Eaton's Intelligent Power Manager (IPM) v 1.67 & prior on file name during configuration file import functionality allows attackers to perform command injection or code execution via specially crafted file names while uploading the configuration file in the application.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| eaton | intelligent_power_manager | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:eaton:intelligent_power_manager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "E94000EF-A58E-4E02-93B2-2FA18D6DD0E6",
"versionEndIncluding": "1.67",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Improper Input Validation in Eaton\u0027s Intelligent Power Manager (IPM) v 1.67 \u0026 prior on file name during configuration file import functionality allows attackers to perform command injection or code execution via specially crafted file names while uploading the configuration file in the application."
},
{
"lang": "es",
"value": "La Comprobaci\u00f3n de Entrada Inapropiada en Eaton Intelligent Power Manager (IPM) versiones v1.67 y anteriores, en el nombre del archivo durante la funcionalidad de importaci\u00f3n del archivo de configuraci\u00f3n permite a atacantes realizar la inyecci\u00f3n de comandos o la ejecuci\u00f3n del c\u00f3digo por medio de nombres de archivo especialmente dise\u00f1ados mientras se carga el archivo de configuraci\u00f3n en la aplicaci\u00f3n."
}
],
"id": "CVE-2020-6651",
"lastModified": "2024-11-21T05:36:05.900",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.8,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "CybersecurityCOE@eaton.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.3,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.3,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2020-05-07T16:15:11.313",
"references": [
{
"source": "CybersecurityCOE@eaton.com",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-vulnerability-advisory-intelligent-power-manager-v1-1.pdf"
},
{
"source": "CybersecurityCOE@eaton.com",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-20-649/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-vulnerability-advisory-intelligent-power-manager-v1-1.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.zerodayinitiative.com/advisories/ZDI-20-649/"
}
],
"sourceIdentifier": "CybersecurityCOE@eaton.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-20"
}
],
"source": "CybersecurityCOE@eaton.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-20"
},
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…