FKIE_CVE-2021-23276
Vulnerability from fkie_nvd - Published: 2021-04-13 19:15 - Updated: 2024-11-21 05:51
Severity ?
7.1 (High) - CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to authenticated SQL injection. A malicious user can send a specially crafted packet to exploit the vulnerability. Successful exploitation of this vulnerability can allow attackers to add users in the data base.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| eaton | intelligent_power_manager | * | |
| eaton | intelligent_power_manager_virtual_appliance | * | |
| eaton | intelligent_power_protector | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:eaton:intelligent_power_manager:*:*:*:*:*:*:*:*",
"matchCriteriaId": "5E2C63CA-B479-49C4-8C98-F5AE9BF06A2F",
"versionEndExcluding": "1.69",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:eaton:intelligent_power_manager_virtual_appliance:*:*:*:*:*:*:*:*",
"matchCriteriaId": "10CFCD42-A9D6-468B-9287-03B4341B129A",
"versionEndExcluding": "1.69",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:eaton:intelligent_power_protector:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4A67B7A8-E508-4854-9437-BF702692948C",
"versionEndExcluding": "1.68",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Eaton Intelligent Power Manager (IPM) prior to 1.69 is vulnerable to authenticated SQL injection. A malicious user can send a specially crafted packet to exploit the vulnerability. Successful exploitation of this vulnerability can allow attackers to add users in the data base."
},
{
"lang": "es",
"value": "Eaton Intelligent Power Manager (IPM) versiones anteriores a 1.69, es vulnerable a una inyecci\u00f3n de SQL autenticado.\u0026#xa0;Un usuario malicioso puede enviar un paquete especialmente dise\u00f1ado para explotar la vulnerabilidad. Una explotaci\u00f3n con \u00e9xito de esta vulnerabilidad puede permitir a atacantes agregar usuarios a la base de datos"
}
],
"id": "CVE-2021-23276",
"lastModified": "2024-11-21T05:51:29.067",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "SINGLE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.5,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:S/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.0,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "HIGH",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.1,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:H/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "CybersecurityCOE@eaton.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-04-13T19:15:14.600",
"references": [
{
"source": "CybersecurityCOE@eaton.com",
"tags": [
"Vendor Advisory"
],
"url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.eaton.com/content/dam/eaton/company/news-insights/cybersecurity/security-bulletins/eaton-intelligent-power-manager-ipm-vulnerability-advisory.pdf"
}
],
"sourceIdentifier": "CybersecurityCOE@eaton.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-89"
}
],
"source": "CybersecurityCOE@eaton.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-89"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…