FKIE_CVE-2021-23849

Vulnerability from fkie_nvd - Published: 2021-08-05 20:15 - Updated: 2024-11-21 05:51
Summary
A vulnerability in the web-based interface allows an unauthenticated remote attacker to trigger actions on an affected system on behalf of another user (CSRF - Cross Site Request Forgery). This requires the victim to be tricked into clicking a malicious link or opening a malicious website while being logged in into the camera.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:bosch:cpp4_firmware:7.10:*:*:*:*:*:*:*",
              "matchCriteriaId": "4763E6AA-5C01-4BE4-9138-167FD46A1D51",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:bosch:cpp4:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "1F4FA4F9-6BDC-44C4-A151-16ECF7926A83",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:bosch:cpp6_firmware:7.60:*:*:*:*:*:*:*",
              "matchCriteriaId": "3C677189-A4A2-428A-8EA8-58B946F00510",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:bosch:cpp6_firmware:7.61:*:*:*:*:*:*:*",
              "matchCriteriaId": "46A4537D-BBB0-44DD-9C84-A1A473F334D5",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:bosch:cpp6_firmware:7.70:*:*:*:*:*:*:*",
              "matchCriteriaId": "ED954BF7-DD03-4B91-8F4F-CACE2E8BDDA0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:bosch:cpp6_firmware:7.80:*:*:*:*:*:*:*",
              "matchCriteriaId": "2124DC0A-3FA5-466B-8A77-A0EB67309D21",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:bosch:cpp6:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "27B65C05-69F5-4048-BCBE-DA0D53EF9AFE",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:bosch:aviotec_firmware:7.61:*:*:*:*:*:*:*",
              "matchCriteriaId": "337D34D8-4576-4326-9F34-05F9CD85C0B9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:bosch:aviotec_firmware:7.72:*:*:*:*:*:*:*",
              "matchCriteriaId": "12E564D5-BFAF-4DAC-94BB-730E0F30DB2A",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:bosch:aviotec:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E7065FC6-BCFB-4B62-B14D-86081EA657E8",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:bosch:cpp7_firmware:7.60:*:*:*:*:*:*:*",
              "matchCriteriaId": "0D9693DA-B74A-47E6-A7AA-A037A263BC48",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:bosch:cpp7_firmware:7.61:*:*:*:*:*:*:*",
              "matchCriteriaId": "C3175C41-22BE-4C7F-8EC7-6A8060ABEB66",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:bosch:cpp7_firmware:7.70:*:*:*:*:*:*:*",
              "matchCriteriaId": "7DA98BAE-2029-43EF-9B62-08183FB24BC1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:bosch:cpp7_firmware:7.72:*:*:*:*:*:*:*",
              "matchCriteriaId": "29E2AC5D-E6AA-4835-95A0-DE4885001BE6",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:bosch:cpp7_firmware:7.80:*:*:*:*:*:*:*",
              "matchCriteriaId": "D63F1A22-F19C-4100-B14A-140FBA5DAD1F",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:bosch:cpp7:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "E8339008-8889-47B0-9416-CCC6CE75D277",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:bosch:cpp7.3_firmware:7.60:*:*:*:*:*:*:*",
              "matchCriteriaId": "417A3399-5CF0-47C5-9209-98F1E8CE579A",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:bosch:cpp7.3_firmware:7.61:*:*:*:*:*:*:*",
              "matchCriteriaId": "60FBA5D6-6A6A-469C-8452-969CA5F21ADC",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:bosch:cpp7.3_firmware:7.62:*:*:*:*:*:*:*",
              "matchCriteriaId": "F0D19012-4183-4293-B98C-292428FB6DB9",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:bosch:cpp7.3_firmware:7.70:*:*:*:*:*:*:*",
              "matchCriteriaId": "7113AE94-1C25-40AF-98F9-0A457DE063B0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:bosch:cpp7.3_firmware:7.72:*:*:*:*:*:*:*",
              "matchCriteriaId": "B0EF3F6B-C978-4BB3-B33E-EA809CE9E851",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:bosch:cpp7.3_firmware:7.73:*:*:*:*:*:*:*",
              "matchCriteriaId": "F74453A8-8055-4A22-98AA-F318B852B316",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:o:bosch:cpp7.3_firmware:7.80:*:*:*:*:*:*:*",
              "matchCriteriaId": "8C0DA3F8-1606-40FA-9E14-C4A53E1DE243",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:bosch:cpp7.3:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "5B97B95A-8143-4766-9F10-87E19AED22C6",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:bosch:cpp13_firmware:7.75:*:*:*:*:*:*:*",
              "matchCriteriaId": "68D04488-DE68-407E-B428-5F51DEA0B07C",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:bosch:cpp13:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "80149FF9-3C6D-4C80-8257-CEB2BE8B0DCA",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:bosch:cpp14_firmware:8.00:*:*:*:*:*:*:*",
              "matchCriteriaId": "89AE2200-8323-4877-B709-E7B856188480",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:bosch:cpp14:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "B7872B92-4708-4522-BA8F-5BE941D169AC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability in the web-based interface allows an unauthenticated remote attacker to trigger actions on an affected system on behalf of another user (CSRF - Cross Site Request Forgery). This requires the victim to be tricked into clicking a malicious link or opening a malicious website while being logged in into the camera."
    },
    {
      "lang": "es",
      "value": "Una vulnerabilidad en la interfaz basada en web permite a un atacante remoto no autenticado desencadenar acciones en un sistema afectado en nombre de otro usuario (CSRF - Cross Site Request Forgery). Esto requiere que la v\u00edctima sea enga\u00f1ada para que haga clic en un enlace malicioso o abra un sitio web malicioso mientras est\u00e1 conectado a la c\u00e1mara"
    }
  ],
  "id": "CVE-2021-23849",
  "lastModified": "2024-11-21T05:51:56.493",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "NONE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.8,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 8.6,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "HIGH",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:H/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.6,
        "impactScore": 5.9,
        "source": "psirt@bosch.com",
        "type": "Secondary"
      },
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2021-08-05T20:15:07.947",
  "references": [
    {
      "source": "psirt@bosch.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://psirt.bosch.com/security-advisories/bosch-sa-033305-bt.html"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://psirt.bosch.com/security-advisories/bosch-sa-033305-bt.html"
    }
  ],
  "sourceIdentifier": "psirt@bosch.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-352"
        }
      ],
      "source": "psirt@bosch.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-352"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…