FKIE_CVE-2021-31538
Vulnerability from fkie_nvd - Published: 2021-06-10 15:15 - Updated: 2024-11-21 06:05
Severity ?
Summary
LANCOM R&S Unified Firewall (UF) devices running LCOS FX 10.5 allow Relative Path Traversal.
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2021-010.txt | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2021-010.txt | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| lancom-systems | lcos_fx | 10.5 | |
| lancom-systems | lcos_fx | 10.5 | |
| lancom-systems | lcos_fx | 10.5 | |
| lancom-systems | lcos_fx | 10.5 | |
| lancom-systems | uf-160 | - | |
| lancom-systems | uf-260 | - | |
| lancom-systems | uf-500 | - | |
| lancom-systems | uf-60 | - | |
| lancom-systems | uf-910 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:lancom-systems:lcos_fx:10.5:-:*:*:*:*:*:*",
"matchCriteriaId": "35289E04-7F27-4D47-B0FD-6ABFE1708C24",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:lancom-systems:lcos_fx:10.5:ru1:*:*:*:*:*:*",
"matchCriteriaId": "0142450C-3A29-440D-84BB-93AAADC09C9C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:lancom-systems:lcos_fx:10.5:ru2:*:*:*:*:*:*",
"matchCriteriaId": "FFEE3742-CF92-4FFB-9581-95B4FAAC6AA3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:lancom-systems:lcos_fx:10.5:ru3:*:*:*:*:*:*",
"matchCriteriaId": "4729094D-FA4B-46A1-9C46-30613ECE3E9D",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:lancom-systems:uf-160:-:*:*:*:*:*:*:*",
"matchCriteriaId": "EEBD7C73-E17B-4450-8F86-16CC4BF665CF",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:lancom-systems:uf-260:-:*:*:*:*:*:*:*",
"matchCriteriaId": "174CCE51-EA04-4F96-ABAD-47E178528FBA",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:lancom-systems:uf-500:-:*:*:*:*:*:*:*",
"matchCriteriaId": "FA412F26-AC3A-4659-8513-873ECC33E965",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:lancom-systems:uf-60:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CD51511B-5824-410A-93E7-10B713A09B6E",
"vulnerable": false
},
{
"criteria": "cpe:2.3:h:lancom-systems:uf-910:-:*:*:*:*:*:*:*",
"matchCriteriaId": "92BF4F29-8262-4905-94BA-798C8F35EEE7",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "LANCOM R\u0026S Unified Firewall (UF) devices running LCOS FX 10.5 allow Relative Path Traversal."
},
{
"lang": "es",
"value": "Los dispositivos LANCOM R\u0026amp;S Unified Firewall (UF) que ejecutan LCOS FX versi\u00f3n 10.5 permiten un Salto de Ruta Relativo"
}
],
"id": "CVE-2021-31538",
"lastModified": "2024-11-21T06:05:52.353",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "NONE",
"baseScore": 5.0,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:L/Au:N/C:P/I:N/A:N",
"version": "2.0"
},
"exploitabilityScore": 10.0,
"impactScore": 2.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-06-10T15:15:09.390",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2021-010.txt"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.syss.de/fileadmin/dokumente/Publikationen/Advisories/SYSS-2021-010.txt"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-22"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…