FKIE_CVE-2021-37202
Vulnerability from fkie_nvd - Published: 2021-09-14 11:15 - Updated: 2024-11-21 06:14
Severity ?
Summary
A vulnerability has been identified in NX 1980 Series (All versions < V1984), Solid Edge SE2021 (All versions < SE2021MP8). The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process.
References
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf | Patch, Vendor Advisory | |
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf | Patch, Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | nx_1980 | * | |
| siemens | solid_edge | * | |
| siemens | solid_edge | se2021 | |
| siemens | solid_edge | se2021 | |
| siemens | solid_edge | se2021 | |
| siemens | solid_edge | se2021 | |
| siemens | solid_edge | se2021 | |
| siemens | solid_edge | se2021 | |
| siemens | solid_edge | se2021 | |
| siemens | solid_edge | se2021 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:nx_1980:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D3A09766-0171-4DDA-9BF9-D379DA134571",
"versionEndExcluding": "1984",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:solid_edge:*:*:*:*:*:*:*:*",
"matchCriteriaId": "576A303A-66CA-4694-AA54-9EB0137C24F1",
"versionEndExcluding": "se2021",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:-:*:*:*:*:*:*",
"matchCriteriaId": "39D237BD-EE55-4B40-ABC3-194C4BF7C6CD",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack1:*:*:*:*:*:*",
"matchCriteriaId": "49F5649A-349C-42C6-AFFF-CEE1ABC14E67",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack2:*:*:*:*:*:*",
"matchCriteriaId": "756343AA-DB57-40F7-94FA-84BFCDEB6159",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack3:*:*:*:*:*:*",
"matchCriteriaId": "36B0DD28-653E-4069-AB5A-38F8EFEB36CA",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack4:*:*:*:*:*:*",
"matchCriteriaId": "82090774-D894-41C8-82F1-A48A8707E9BB",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack5:*:*:*:*:*:*",
"matchCriteriaId": "BD346D22-9B5D-4A50-94E2-1F5C8D391EC3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack6:*:*:*:*:*:*",
"matchCriteriaId": "1466AEE0-4A5C-4E2D-80B8-43680F60FC31",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:solid_edge:se2021:maintenance_pack7:*:*:*:*:*:*",
"matchCriteriaId": "A4173D09-C317-45FF-ABA4-39E5592862F8",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in NX 1980 Series (All versions \u003c V1984), Solid Edge SE2021 (All versions \u003c SE2021MP8). The IFC adapter in affected application contains a use-after-free vulnerability that could be triggered while parsing user-supplied IFC files. An attacker could leverage this vulnerability to execute code in the context of the current process."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en NX 1980 Series (Todas las versiones anteriores a V1984), Solid Edge SE2021 (Todas las versiones anteriores a SE2021MP8). El adaptador IFC de la aplicaci\u00f3n afectada contiene una vulnerabilidad de uso despu\u00e9s de libre que podr\u00eda activarse mientras se analizan los archivos IFC suministrados por el usuario. Un atacante podr\u00eda aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del proceso actual"
}
],
"id": "CVE-2021-37202",
"lastModified": "2024-11-21T06:14:51.100",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "PARTIAL",
"baseScore": 6.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:M/Au:N/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": true
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "REQUIRED",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2021-09-14T11:15:26.397",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf"
},
{
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-208530.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-728618.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-416"
}
],
"source": "productcert@siemens.com",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…