FKIE_CVE-2022-23448
Vulnerability from fkie_nvd - Published: 2022-04-12 09:15 - Updated: 2024-11-21 06:48
Severity ?
Summary
A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions < V7.3 Update 1), SIMATIC Energy Manager PRO (All versions < V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges.
References
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf | Mitigation, Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf | Mitigation, Patch, Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | simatic_energy_manager_basic | * | |
| siemens | simatic_energy_manager_basic | 7.3 | |
| siemens | simatic_energy_manager_pro | * | |
| siemens | simatic_energy_manager_pro | 7.3 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:siemens:simatic_energy_manager_basic:*:*:*:*:*:*:*:*",
"matchCriteriaId": "2BDBCB2C-E9EB-4AF6-B47A-22B27AE41178",
"versionEndExcluding": "7.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_energy_manager_basic:7.3:-:*:*:*:*:*:*",
"matchCriteriaId": "1BB78E93-7C0A-4F59-B6EA-3D5A681BFE8F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_energy_manager_pro:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4B1E608C-3C6F-45FB-86C9-E99E7F21836D",
"versionEndExcluding": "7.3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:a:siemens:simatic_energy_manager_pro:7.3:-:*:*:*:*:*:*",
"matchCriteriaId": "34A11AF9-7F0C-4151-8A4D-A8E1BDCBA525",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in SIMATIC Energy Manager Basic (All versions \u003c V7.3 Update 1), SIMATIC Energy Manager PRO (All versions \u003c V7.3 Update 1). Affected applications improperly assign permissions to critical directories and files used by the application processes. This could allow a local unprivileged attacker to achieve code execution with ADMINISTRATOR or even NT AUTHORITY/SYSTEM privileges."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en SIMATIC Energy Manager Basic (todas las versiones anteriores a V7.3 Update 1), SIMATIC Energy Manager PRO (todas las versiones anteriores a V7.3 Update 1). Las aplicaciones afectadas asignan inapropiadamente los permisos a directorios y archivos cr\u00edticos usados por los procesos de la aplicaci\u00f3n. Esto podr\u00eda permitir a un atacante local no privilegiado lograr la ejecuci\u00f3n de c\u00f3digo con privilegios de ADMINISTRADOR o incluso de NT AUTHORITY/SYSTEM"
}
],
"id": "CVE-2022-23448",
"lastModified": "2024-11-21T06:48:34.530",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "LOCAL",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.2,
"confidentialityImpact": "COMPLETE",
"integrityImpact": "COMPLETE",
"vectorString": "AV:L/AC:L/Au:N/C:C/I:C/A:C",
"version": "2.0"
},
"exploitabilityScore": 3.9,
"impactScore": 10.0,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-04-12T09:15:14.233",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-655554.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-732"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-732"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…