FKIE_CVE-2022-26388
Vulnerability from fkie_nvd - Published: 2025-02-07 17:15 - Updated: 2025-02-07 17:15
Severity ?
Summary
A use of hard-coded password vulnerability may allow authentication abuse.This issue affects ELI 380 Resting Electrocardiograph:
Versions 2.6.0 and prior; ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph:
Versions 2.3.1 and prior; ELI 250c/BUR 250c Resting Electrocardiograph:
Versions 2.1.2 and prior; ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph:
Versions 2.2.0 and prior.
References
Impacted products
| Vendor | Product | Version |
|---|
{
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A use of hard-coded password vulnerability may allow authentication abuse.This issue affects ELI 380 Resting Electrocardiograph: \n\nVersions 2.6.0 and prior; ELI 280/BUR280/MLBUR 280 Resting Electrocardiograph:\n\nVersions 2.3.1 and prior; ELI 250c/BUR 250c Resting Electrocardiograph:\n\nVersions 2.1.2 and prior; ELI 150c/BUR 150c/MLBUR 150c Resting Electrocardiograph: \n\nVersions 2.2.0 and prior."
},
{
"lang": "es",
"value": "Una vulnerabilidad en el uso de contrase\u00f1as codificadas de forma r\u00edgida puede permitir el abuso de la autenticaci\u00f3n. Este problema afecta al electrocardi\u00f3grafo en reposo ELI 380: versiones 2.6.0 y anteriores; al electrocardi\u00f3grafo en reposo ELI 280/BUR280/MLBUR 280: versiones 2.3.1 y anteriores; al electrocardi\u00f3grafo en reposo ELI 250c/BUR 250c: versiones 2.1.2 y anteriores; al electrocardi\u00f3grafo en reposo ELI 150c/BUR 150c/MLBUR 150c: versiones 2.2.0 y anteriores."
}
],
"id": "CVE-2022-26388",
"lastModified": "2025-02-07T17:15:21.960",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "LOW",
"baseScore": 6.4,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:L",
"version": "3.1"
},
"exploitabilityScore": 0.9,
"impactScore": 5.5,
"source": "productsecurity@baxter.com",
"type": "Secondary"
}
]
},
"published": "2025-02-07T17:15:21.960",
"references": [
{
"source": "productsecurity@baxter.com",
"url": "https://hillrom.com/en/responsible-disclosures/"
},
{
"source": "productsecurity@baxter.com",
"url": "https://www.cisa.gov/news-events/ics-medical-advisories/icsma-22-167-01"
}
],
"sourceIdentifier": "productsecurity@baxter.com",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-259"
}
],
"source": "productsecurity@baxter.com",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…