FKIE_CVE-2022-29884
Vulnerability from fkie_nvd - Published: 2022-07-12 10:15 - Updated: 2024-11-21 06:59
Severity ?
Summary
A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70°C (All versions < CPC80 V16.30), CP-8000 MASTER MODULE WITH I/O -40/+70°C (All versions < CPC80 V16.30), CP-8021 MASTER MODULE (All versions < CPC80 V16.30), CP-8022 MASTER MODULE WITH GPRS (All versions < CPC80 V16.30). When using the HTTPS server under specific conditions, affected devices do not properly free resources. This could allow an unauthenticated remote attacker to put the device into a denial of service condition.
References
| URL | Tags | ||
|---|---|---|---|
| productcert@siemens.com | https://cert-portal.siemens.com/productcert/pdf/ssa-491621.pdf | Patch, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://cert-portal.siemens.com/productcert/pdf/ssa-491621.pdf | Patch, Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| siemens | sicam_a8000_cp-8000_firmware | * | |
| siemens | sicam_a8000_cp-8000 | - | |
| siemens | sicam_a8000_cp-8021_firmware | * | |
| siemens | sicam_a8000_cp-8021 | - | |
| siemens | sicam_a8000_cp-8022_firmware | * | |
| siemens | sicam_a8000_cp-8022 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sicam_a8000_cp-8000_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "6A3EDA09-C712-416E-BEE4-B49F867FEB56",
"versionEndExcluding": "16.30",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sicam_a8000_cp-8000:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8DEF18ED-BF87-4CFA-A4BA-3387AC8964B3",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sicam_a8000_cp-8021_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "41F8797E-D4EC-4758-B526-35178F304DE1",
"versionEndExcluding": "16.30",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sicam_a8000_cp-8021:-:*:*:*:*:*:*:*",
"matchCriteriaId": "65362A2F-DB6D-4D7F-87B5-10E18EE990F0",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:siemens:sicam_a8000_cp-8022_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1182239D-D513-4C0F-8460-D4BDD6A2373A",
"versionEndExcluding": "16.30",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:siemens:sicam_a8000_cp-8022:-:*:*:*:*:*:*:*",
"matchCriteriaId": "64D59FE8-03FD-4E5B-B7D2-47F31E98A187",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been identified in CP-8000 MASTER MODULE WITH I/O -25/+70\u00b0C (All versions \u003c CPC80 V16.30), CP-8000 MASTER MODULE WITH I/O -40/+70\u00b0C (All versions \u003c CPC80 V16.30), CP-8021 MASTER MODULE (All versions \u003c CPC80 V16.30), CP-8022 MASTER MODULE WITH GPRS (All versions \u003c CPC80 V16.30). When using the HTTPS server under specific conditions, affected devices do not properly free resources. This could allow an unauthenticated remote attacker to put the device into a denial of service condition."
},
{
"lang": "es",
"value": "Se ha identificado una vulnerabilidad en el MASTER MODULE CP-8000 CON E/S -25/+70\u00b0C (Todas las versiones anteriores a CPC80 V16.30), MASTER MODULE CP-8000 CON E/S -40/+70\u00b0C (Todas las versiones anteriores a CPC80 V16.30), MASTER MODULE CP-8021 (Todas las versiones anteriores a CPC80 V16.30), MASTER MODULE CP-8022 CON GPRS (Todas las versiones anteriores a CPC80 V16.30). Cuando es usado el servidor HTTPS en condiciones espec\u00edficas, los dispositivos afectados no liberan apropiadamente los recursos. Esto podr\u00eda permitir a un atacante remoto no autenticado poner el dispositivo en una condici\u00f3n de denegaci\u00f3n de servicio"
}
],
"id": "CVE-2022-29884",
"lastModified": "2024-11-21T06:59:54.170",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "HIGH",
"cvssData": {
"accessComplexity": "MEDIUM",
"accessVector": "NETWORK",
"authentication": "NONE",
"availabilityImpact": "COMPLETE",
"baseScore": 7.1,
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"vectorString": "AV:N/AC:M/Au:N/C:N/I:N/A:C",
"version": "2.0"
},
"exploitabilityScore": 8.6,
"impactScore": 6.9,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "nvd@nist.gov",
"type": "Primary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2022-07-12T10:15:10.547",
"references": [
{
"source": "productcert@siemens.com",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491621.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Patch",
"Vendor Advisory"
],
"url": "https://cert-portal.siemens.com/productcert/pdf/ssa-491621.pdf"
}
],
"sourceIdentifier": "productcert@siemens.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-772"
}
],
"source": "productcert@siemens.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-772"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…