FKIE_CVE-2022-33137

Vulnerability from fkie_nvd - Published: 2022-07-12 10:15 - Updated: 2024-11-21 07:07
Summary
A vulnerability has been identified in SIMATIC MV540 H (All versions < V3.3), SIMATIC MV540 S (All versions < V3.3), SIMATIC MV550 H (All versions < V3.3), SIMATIC MV550 S (All versions < V3.3), SIMATIC MV560 U (All versions < V3.3), SIMATIC MV560 X (All versions < V3.3). The web session management of affected devices does not invalidate session ids in certain logout scenarios. This could allow an authenticated remote attacker to hijack other users' sessions.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_mv540_h_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A6527D89-4A8F-4A97-B2E9-CFBC9593DEB7",
              "versionEndExcluding": "3.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_mv540_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "18944887-DE3F-4FB4-88D2-1C8EC89A1481",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_mv540_s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "0557AB45-C9F1-4F67-BD8D-E5AD706CCACF",
              "versionEndExcluding": "3.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_mv540_s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B016178-2DCB-417C-B20F-8B9E1904BE8C",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_mv550_h_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7EFEE0CC-F494-4B57-8DF1-68954C4AA144",
              "versionEndExcluding": "3.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_mv550_h:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "324A87A6-2DC6-4797-8191-0BE2D8D1F9FC",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_mv550_s_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "AC4115D9-D589-4EE4-AFC8-D3C103A84DA2",
              "versionEndExcluding": "3.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_mv550_s:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "4B6E1134-8C21-4045-BD02-F44250474C40",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_mv560_u_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "E9DEAF0E-48DB-4499-835B-96E17B8DD738",
              "versionEndExcluding": "3.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_mv560_u:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "D2FBB8F8-C886-4A2B-8808-6E3D6A57B271",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    },
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:o:siemens:simatic_mv560_x_firmware:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "99359BFA-BBA9-423F-A12B-1E9AF673CB91",
              "versionEndExcluding": "3.3",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        },
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:h:siemens:simatic_mv560_x:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "DAA25C73-59D0-469D-BE6F-6188F645C1D9",
              "vulnerable": false
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ],
      "operator": "AND"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC MV540 H (All versions \u003c V3.3), SIMATIC MV540 S (All versions \u003c V3.3), SIMATIC MV550 H (All versions \u003c V3.3), SIMATIC MV550 S (All versions \u003c V3.3), SIMATIC MV560 U (All versions \u003c V3.3), SIMATIC MV560 X (All versions \u003c V3.3). The web session management of affected devices does not invalidate session ids in certain logout scenarios. This could allow an authenticated remote attacker to hijack other users\u0027 sessions."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC MV540 H (Todas las versiones anteriores a V3.3), SIMATIC MV540 S (Todas las versiones anteriores a V3.3), SIMATIC MV550 H (Todas las versiones anteriores a V3.3), SIMATIC MV550 S (Todas las versiones anteriores a V3.3), SIMATIC MV560 U (Todas las versiones anteriores a V3.3), SIMATIC MV560 X (Todas las versiones anteriores a V3.3). La administraci\u00f3n de sesiones web de los dispositivos afectados no invalida los identificadores de sesi\u00f3n en determinados escenarios de cierre de sesi\u00f3n. Esto podr\u00eda permitir a un atacante remoto autenticado secuestrar las sesiones de otros usuarios"
    }
  ],
  "id": "CVE-2022-33137",
  "lastModified": "2024-11-21T07:07:35.047",
  "metrics": {
    "cvssMetricV2": [
      {
        "acInsufInfo": false,
        "baseSeverity": "MEDIUM",
        "cvssData": {
          "accessComplexity": "MEDIUM",
          "accessVector": "NETWORK",
          "authentication": "SINGLE",
          "availabilityImpact": "PARTIAL",
          "baseScore": 6.0,
          "confidentialityImpact": "PARTIAL",
          "integrityImpact": "PARTIAL",
          "vectorString": "AV:N/AC:M/Au:S/C:P/I:P/A:P",
          "version": "2.0"
        },
        "exploitabilityScore": 6.8,
        "impactScore": 6.4,
        "obtainAllPrivilege": false,
        "obtainOtherPrivilege": false,
        "obtainUserPrivilege": false,
        "source": "nvd@nist.gov",
        "type": "Primary",
        "userInteractionRequired": true
      }
    ],
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.0,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.1,
        "impactScore": 5.9,
        "source": "nvd@nist.gov",
        "type": "Primary"
      }
    ]
  },
  "published": "2022-07-12T10:15:10.707",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Patch",
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-348662.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-613"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    },
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-613"
        }
      ],
      "source": "nvd@nist.gov",
      "type": "Primary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…