FKIE_CVE-2023-24229
Vulnerability from fkie_nvd - Published: 2023-03-15 18:15 - Updated: 2024-11-21 07:47
Severity ?
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
7.8 (High) - CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
DrayTek Vigor2960 v1.5.1.4 allows an authenticated attacker with network access to the web management interface to inject operating system commands via the mainfunction.cgi 'parameter' parameter. NOTE: This vulnerability only affects products that are no longer supported by the maintainer.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| draytek | vigor2960_firmware | 1.5.1.4 | |
| draytek | vigor2960 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:draytek:vigor2960_firmware:1.5.1.4:*:*:*:*:*:*:*",
"matchCriteriaId": "564753CE-A701-4D76-94D8-C452AF0C5E82",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:draytek:vigor2960:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8FDA3905-67DD-4F31-AFCF-014F1D7CCC1F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [
{
"sourceIdentifier": "cve@mitre.org",
"tags": [
"unsupported-when-assigned"
]
}
],
"descriptions": [
{
"lang": "en",
"value": "DrayTek Vigor2960 v1.5.1.4 allows an authenticated attacker with network access to the web management interface to inject operating system commands via the mainfunction.cgi \u0027parameter\u0027 parameter. NOTE: This vulnerability only affects products that are no longer supported by the maintainer."
}
],
"id": "CVE-2023-24229",
"lastModified": "2024-11-21T07:47:36.267",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2023-03-15T18:15:10.460",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/sadwwcxz/Vul"
},
{
"source": "cve@mitre.org",
"url": "https://web.archive.org/web/20230315181013/https://github.com/sadwwcxz/Vul"
},
{
"source": "cve@mitre.org",
"url": "https://www.draytek.co.uk/support/guides/kb-remotemanagement"
},
{
"source": "cve@mitre.org",
"tags": [
"Not Applicable"
],
"url": "https://www.draytek.com/"
},
{
"source": "cve@mitre.org",
"url": "https://www.draytek.com/about/newsroom/2021/2021/end-of-life-notification-vigor2960"
},
{
"source": "cve@mitre.org",
"url": "https://www.draytek.com/support/knowledge-base/5465"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/sadwwcxz/Vul"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://web.archive.org/web/20230315181013/https://github.com/sadwwcxz/Vul"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.draytek.co.uk/support/guides/kb-remotemanagement"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Not Applicable"
],
"url": "https://www.draytek.com/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.draytek.com/about/newsroom/2021/2021/end-of-life-notification-vigor2960"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "https://www.draytek.com/support/knowledge-base/5465"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…