FKIE_CVE-2023-31222
Vulnerability from fkie_nvd - Published: 2023-06-29 16:15 - Updated: 2024-11-21 08:01
Severity ?
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H
Summary
Deserialization of untrusted data in Microsoft Messaging Queuing Service in Medtronic's Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a healthcare delivery organization’s Paceart Optima system cardiac device causing data to be deleted, stolen, or modified, or the Paceart Optima system being used for further network penetration via network connectivity.
References
| URL | Tags | ||
|---|---|---|---|
| security@medtronic.com | https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html | Mitigation, Vendor Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html | Mitigation, Vendor Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| medtronic | paceart_optima | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:medtronic:paceart_optima:*:*:*:*:*:windows:*:*",
"matchCriteriaId": "A39B5C21-C4A0-4F23-93BF-A0E5AA01DA65",
"versionEndExcluding": "1.12",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Deserialization of untrusted data\u00a0in Microsoft Messaging Queuing Service in Medtronic\u0027s Paceart Optima versions 1.11 and earlier on Windows allows an unauthorized user to impact a\u00a0healthcare delivery organization\u2019s Paceart Optima system\u00a0cardiac device causing data to be deleted, stolen, or modified, or the Paceart Optima system being used for further network penetration\u00a0via network connectivity."
}
],
"id": "CVE-2023-31222",
"lastModified": "2024-11-21T08:01:39.230",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "security@medtronic.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-06-29T16:15:09.777",
"references": [
{
"source": "security@medtronic.com",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Mitigation",
"Vendor Advisory"
],
"url": "https://global.medtronic.com/xg-en/product-security/security-bulletins/paceart-optima-system.html"
}
],
"sourceIdentifier": "security@medtronic.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-502"
}
],
"source": "security@medtronic.com",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-502"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…