Summary
Dell Wyse ThinOS versions prior to 2303 (9.4.1141) contain a sensitive information disclosure vulnerability. An unauthenticated malicious user with local access to the device could exploit this vulnerability to read sensitive information written to the log files.
References
Impacted products
Vendor | Product | Version | |
---|---|---|---|
dell | wyse_thinos | 9.4.1141 | |
dell | latitude_3420 | - | |
dell | latitude_3440 | - | |
dell | latitude_5440 | - | |
dell | optiplex_3000_thin_client | - | |
dell | optiplex_5400 | - | |
dell | wyse_3040_thin_client | - | |
dell | wyse_5070_thin_client | - | |
dell | wyse_5470_all-in-one_thin_client | - | |
dell | wyse_5470_mobile_thin_client | - |
{ "configurations": [ { "nodes": [ { "cpeMatch": [ { "criteria": "cpe:2.3:o:dell:wyse_thinos:9.4.1141:*:*:*:*:*:*:*", "matchCriteriaId": "E2948904-C750-4A0A-B8F8-74D481D5D9DE", "vulnerable": true } ], "negate": false, "operator": "OR" }, { "cpeMatch": [ { "criteria": "cpe:2.3:h:dell:latitude_3420:-:*:*:*:*:*:*:*", "matchCriteriaId": "7FB6E60F-F100-42BF-BC38-A38620EF8D2C", "vulnerable": false }, { "criteria": "cpe:2.3:h:dell:latitude_3440:-:*:*:*:*:*:*:*", "matchCriteriaId": "31C78A9B-65B4-4213-9A96-4E57CFA5B195", "vulnerable": false }, { "criteria": "cpe:2.3:h:dell:latitude_5440:-:*:*:*:*:*:*:*", "matchCriteriaId": "84EC8EA3-A91D-4D3B-B1A5-D650A526CAAE", "vulnerable": false }, { "criteria": "cpe:2.3:h:dell:optiplex_3000_thin_client:-:*:*:*:*:*:*:*", "matchCriteriaId": "1C4B0B6B-7740-46D0-9FE0-3AFF8D9B4DDA", "vulnerable": false }, { "criteria": "cpe:2.3:h:dell:optiplex_5400:-:*:*:*:*:*:*:*", "matchCriteriaId": "F53D91BF-DA1C-4BFB-9E17-AB5266DB255F", "vulnerable": false }, { "criteria": "cpe:2.3:h:dell:wyse_3040_thin_client:-:*:*:*:*:*:*:*", "matchCriteriaId": "EE7CF2EF-93B1-4026-B923-3E08324245BD", "vulnerable": false }, { "criteria": "cpe:2.3:h:dell:wyse_5070_thin_client:-:*:*:*:*:*:*:*", "matchCriteriaId": "C1664E2E-057D-4A8F-B8FC-73EC25D48DBC", "vulnerable": false }, { "criteria": "cpe:2.3:h:dell:wyse_5470_all-in-one_thin_client:-:*:*:*:*:*:*:*", "matchCriteriaId": "3929B7A4-D181-4258-8722-57A751DB4CCC", "vulnerable": false }, { "criteria": "cpe:2.3:h:dell:wyse_5470_mobile_thin_client:-:*:*:*:*:*:*:*", "matchCriteriaId": "1D9B6263-FF2F-428D-971B-48029951E62B", "vulnerable": false } ], "negate": false, "operator": "OR" } ], "operator": "AND" } ], "cveTags": [], "descriptions": [ { "lang": "en", "value": "\nDell Wyse ThinOS versions prior to 2303 (9.4.1141) contain a sensitive information disclosure vulnerability. An unauthenticated malicious user with local access to the device could exploit this vulnerability to read sensitive information written to the log files.\n\n" } ], "id": "CVE-2023-32446", "lastModified": "2024-11-21T08:03:22.130", "metrics": { "cvssMetricV31": [ { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "security_alert@emc.com", "type": "Secondary" }, { "cvssData": { "attackComplexity": "LOW", "attackVector": "LOCAL", "availabilityImpact": "NONE", "baseScore": 5.5, "baseSeverity": "MEDIUM", "confidentialityImpact": "HIGH", "integrityImpact": "NONE", "privilegesRequired": "LOW", "scope": "UNCHANGED", "userInteraction": "NONE", "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N", "version": "3.1" }, "exploitabilityScore": 1.8, "impactScore": 3.6, "source": "nvd@nist.gov", "type": "Primary" } ] }, "published": "2023-07-20T13:15:10.917", "references": [ { "source": "security_alert@emc.com", "tags": [ "Vendor Advisory" ], "url": "https://www.dell.com/support/kbdoc/en-us/000215864/dsa-2023-247" }, { "source": "af854a3a-2127-422b-91ae-364da2661108", "tags": [ "Vendor Advisory" ], "url": "https://www.dell.com/support/kbdoc/en-us/000215864/dsa-2023-247" } ], "sourceIdentifier": "security_alert@emc.com", "vulnStatus": "Modified", "weaknesses": [ { "description": [ { "lang": "en", "value": "CWE-312" } ], "source": "security_alert@emc.com", "type": "Secondary" }, { "description": [ { "lang": "en", "value": "CWE-532" } ], "source": "nvd@nist.gov", "type": "Primary" } ] }
Loading…
Loading…
Sightings
Author | Source | Type | Date |
---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or seen somewhere by the user.
- Confirmed: The vulnerability is confirmed from an analyst perspective.
- Exploited: This vulnerability was exploited and seen by the user reporting the sighting.
- Patched: This vulnerability was successfully patched by the user reporting the sighting.
- Not exploited: This vulnerability was not exploited or seen by the user reporting the sighting.
- Not confirmed: The user expresses doubt about the veracity of the vulnerability.