CVE-2023-32446 (GCVE-0-2023-32446)

Vulnerability from cvelistv5 – Published: 2023-07-20 12:50 – Updated: 2024-10-17 14:12
VLAI?
Summary
Dell Wyse ThinOS versions prior to 2303 (9.4.1141) contain a sensitive information disclosure vulnerability. An unauthenticated malicious user with local access to the device could exploit this vulnerability to read sensitive information written to the log files.
CWE
  • CWE-312 - Cleartext Storage of Sensitive Information
Assigner
References
Impacted products
Show details on NVD website

{
  "containers": {
    "adp": [
      {
        "providerMetadata": {
          "dateUpdated": "2024-08-02T15:18:37.105Z",
          "orgId": "af854a3a-2127-422b-91ae-364da2661108",
          "shortName": "CVE"
        },
        "references": [
          {
            "tags": [
              "vendor-advisory",
              "x_transferred"
            ],
            "url": "https://www.dell.com/support/kbdoc/en-us/000215864/dsa-2023-247"
          }
        ],
        "title": "CVE Program Container"
      },
      {
        "metrics": [
          {
            "other": {
              "content": {
                "id": "CVE-2023-32446",
                "options": [
                  {
                    "Exploitation": "none"
                  },
                  {
                    "Automatable": "no"
                  },
                  {
                    "Technical Impact": "partial"
                  }
                ],
                "role": "CISA Coordinator",
                "timestamp": "2024-10-17T14:09:30.428461Z",
                "version": "2.0.3"
              },
              "type": "ssvc"
            }
          }
        ],
        "providerMetadata": {
          "dateUpdated": "2024-10-17T14:12:16.678Z",
          "orgId": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
          "shortName": "CISA-ADP"
        },
        "title": "CISA ADP Vulnrichment"
      }
    ],
    "cna": {
      "affected": [
        {
          "defaultStatus": "unaffected",
          "product": "Wyse Proprietary OS (Modern ThinOS)",
          "vendor": "Dell",
          "versions": [
            {
              "status": "affected",
              "version": "2303 (9.4.1141)"
            }
          ]
        }
      ],
      "datePublic": "2023-07-18T06:30:00.000Z",
      "descriptions": [
        {
          "lang": "en",
          "supportingMedia": [
            {
              "base64": false,
              "type": "text/html",
              "value": "\n\n\u003cspan style=\"background-color: rgb(255, 255, 255);\"\u003eDell Wyse ThinOS versions prior to 2303 (9.4.1141) contain a sensitive information disclosure vulnerability. An unauthenticated malicious user with local access to the device could exploit this vulnerability to read sensitive information written to the log files.\u003c/span\u003e\n\n"
            }
          ],
          "value": "\nDell Wyse ThinOS versions prior to 2303 (9.4.1141) contain a sensitive information disclosure vulnerability. An unauthenticated malicious user with local access to the device could exploit this vulnerability to read sensitive information written to the log files.\n\n"
        }
      ],
      "metrics": [
        {
          "cvssV3_1": {
            "attackComplexity": "LOW",
            "attackVector": "LOCAL",
            "availabilityImpact": "NONE",
            "baseScore": 5.5,
            "baseSeverity": "MEDIUM",
            "confidentialityImpact": "HIGH",
            "integrityImpact": "NONE",
            "privilegesRequired": "LOW",
            "scope": "UNCHANGED",
            "userInteraction": "NONE",
            "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N",
            "version": "3.1"
          },
          "format": "CVSS",
          "scenarios": [
            {
              "lang": "en",
              "value": "GENERAL"
            }
          ]
        }
      ],
      "problemTypes": [
        {
          "descriptions": [
            {
              "cweId": "CWE-312",
              "description": "CWE-312: Cleartext Storage of Sensitive Information",
              "lang": "en",
              "type": "CWE"
            }
          ]
        }
      ],
      "providerMetadata": {
        "dateUpdated": "2023-07-20T12:50:47.946Z",
        "orgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
        "shortName": "dell"
      },
      "references": [
        {
          "tags": [
            "vendor-advisory"
          ],
          "url": "https://www.dell.com/support/kbdoc/en-us/000215864/dsa-2023-247"
        }
      ],
      "source": {
        "discovery": "UNKNOWN"
      },
      "x_generator": {
        "engine": "Vulnogram 0.1.0-dev"
      }
    }
  },
  "cveMetadata": {
    "assignerOrgId": "c550e75a-17ff-4988-97f0-544cde3820fe",
    "assignerShortName": "dell",
    "cveId": "CVE-2023-32446",
    "datePublished": "2023-07-20T12:50:47.946Z",
    "dateReserved": "2023-05-09T06:02:34.290Z",
    "dateUpdated": "2024-10-17T14:12:16.678Z",
    "state": "PUBLISHED"
  },
  "dataType": "CVE_RECORD",
  "dataVersion": "5.1",
  "vulnerability-lookup:meta": {
    "fkie_nvd": {
      "configurations": "[{\"operator\": \"AND\", \"nodes\": [{\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": true, \"criteria\": \"cpe:2.3:o:dell:wyse_thinos:9.4.1141:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"E2948904-C750-4A0A-B8F8-74D481D5D9DE\"}]}, {\"operator\": \"OR\", \"negate\": false, \"cpeMatch\": [{\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:latitude_3420:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"7FB6E60F-F100-42BF-BC38-A38620EF8D2C\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:latitude_3440:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"31C78A9B-65B4-4213-9A96-4E57CFA5B195\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:latitude_5440:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"84EC8EA3-A91D-4D3B-B1A5-D650A526CAAE\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:optiplex_3000_thin_client:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1C4B0B6B-7740-46D0-9FE0-3AFF8D9B4DDA\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:optiplex_5400:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"F53D91BF-DA1C-4BFB-9E17-AB5266DB255F\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:wyse_3040_thin_client:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"EE7CF2EF-93B1-4026-B923-3E08324245BD\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:wyse_5070_thin_client:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"C1664E2E-057D-4A8F-B8FC-73EC25D48DBC\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:wyse_5470_all-in-one_thin_client:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"3929B7A4-D181-4258-8722-57A751DB4CCC\"}, {\"vulnerable\": false, \"criteria\": \"cpe:2.3:h:dell:wyse_5470_mobile_thin_client:-:*:*:*:*:*:*:*\", \"matchCriteriaId\": \"1D9B6263-FF2F-428D-971B-48029951E62B\"}]}]}]",
      "descriptions": "[{\"lang\": \"en\", \"value\": \"\\nDell Wyse ThinOS versions prior to 2303 (9.4.1141) contain a sensitive information disclosure vulnerability. An unauthenticated malicious user with local access to the device could exploit this vulnerability to read sensitive information written to the log files.\\n\\n\"}]",
      "id": "CVE-2023-32446",
      "lastModified": "2024-11-21T08:03:22.130",
      "metrics": "{\"cvssMetricV31\": [{\"source\": \"security_alert@emc.com\", \"type\": \"Secondary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 5.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 3.6}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"cvssData\": {\"version\": \"3.1\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\", \"baseScore\": 5.5, \"baseSeverity\": \"MEDIUM\", \"attackVector\": \"LOCAL\", \"attackComplexity\": \"LOW\", \"privilegesRequired\": \"LOW\", \"userInteraction\": \"NONE\", \"scope\": \"UNCHANGED\", \"confidentialityImpact\": \"HIGH\", \"integrityImpact\": \"NONE\", \"availabilityImpact\": \"NONE\"}, \"exploitabilityScore\": 1.8, \"impactScore\": 3.6}]}",
      "published": "2023-07-20T13:15:10.917",
      "references": "[{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000215864/dsa-2023-247\", \"source\": \"security_alert@emc.com\", \"tags\": [\"Vendor Advisory\"]}, {\"url\": \"https://www.dell.com/support/kbdoc/en-us/000215864/dsa-2023-247\", \"source\": \"af854a3a-2127-422b-91ae-364da2661108\", \"tags\": [\"Vendor Advisory\"]}]",
      "sourceIdentifier": "security_alert@emc.com",
      "vulnStatus": "Modified",
      "weaknesses": "[{\"source\": \"security_alert@emc.com\", \"type\": \"Secondary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-312\"}]}, {\"source\": \"nvd@nist.gov\", \"type\": \"Primary\", \"description\": [{\"lang\": \"en\", \"value\": \"CWE-532\"}]}]"
    },
    "nvd": "{\"cve\":{\"id\":\"CVE-2023-32446\",\"sourceIdentifier\":\"security_alert@emc.com\",\"published\":\"2023-07-20T13:15:10.917\",\"lastModified\":\"2024-11-21T08:03:22.130\",\"vulnStatus\":\"Modified\",\"cveTags\":[],\"descriptions\":[{\"lang\":\"en\",\"value\":\"\\nDell Wyse ThinOS versions prior to 2303 (9.4.1141) contain a sensitive information disclosure vulnerability. An unauthenticated malicious user with local access to the device could exploit this vulnerability to read sensitive information written to the log files.\\n\\n\"}],\"metrics\":{\"cvssMetricV31\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"cvssData\":{\"version\":\"3.1\",\"vectorString\":\"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\",\"baseScore\":5.5,\"baseSeverity\":\"MEDIUM\",\"attackVector\":\"LOCAL\",\"attackComplexity\":\"LOW\",\"privilegesRequired\":\"LOW\",\"userInteraction\":\"NONE\",\"scope\":\"UNCHANGED\",\"confidentialityImpact\":\"HIGH\",\"integrityImpact\":\"NONE\",\"availabilityImpact\":\"NONE\"},\"exploitabilityScore\":1.8,\"impactScore\":3.6}]},\"weaknesses\":[{\"source\":\"security_alert@emc.com\",\"type\":\"Secondary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-312\"}]},{\"source\":\"nvd@nist.gov\",\"type\":\"Primary\",\"description\":[{\"lang\":\"en\",\"value\":\"CWE-532\"}]}],\"configurations\":[{\"operator\":\"AND\",\"nodes\":[{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":true,\"criteria\":\"cpe:2.3:o:dell:wyse_thinos:9.4.1141:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"E2948904-C750-4A0A-B8F8-74D481D5D9DE\"}]},{\"operator\":\"OR\",\"negate\":false,\"cpeMatch\":[{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:latitude_3420:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"7FB6E60F-F100-42BF-BC38-A38620EF8D2C\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:latitude_3440:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"31C78A9B-65B4-4213-9A96-4E57CFA5B195\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:latitude_5440:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"84EC8EA3-A91D-4D3B-B1A5-D650A526CAAE\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:optiplex_3000_thin_client:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1C4B0B6B-7740-46D0-9FE0-3AFF8D9B4DDA\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:optiplex_5400:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"F53D91BF-DA1C-4BFB-9E17-AB5266DB255F\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:wyse_3040_thin_client:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"EE7CF2EF-93B1-4026-B923-3E08324245BD\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:wyse_5070_thin_client:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"C1664E2E-057D-4A8F-B8FC-73EC25D48DBC\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:wyse_5470_all-in-one_thin_client:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"3929B7A4-D181-4258-8722-57A751DB4CCC\"},{\"vulnerable\":false,\"criteria\":\"cpe:2.3:h:dell:wyse_5470_mobile_thin_client:-:*:*:*:*:*:*:*\",\"matchCriteriaId\":\"1D9B6263-FF2F-428D-971B-48029951E62B\"}]}]}],\"references\":[{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000215864/dsa-2023-247\",\"source\":\"security_alert@emc.com\",\"tags\":[\"Vendor Advisory\"]},{\"url\":\"https://www.dell.com/support/kbdoc/en-us/000215864/dsa-2023-247\",\"source\":\"af854a3a-2127-422b-91ae-364da2661108\",\"tags\":[\"Vendor Advisory\"]}]}}",
    "vulnrichment": {
      "containers": "{\"adp\": [{\"title\": \"CVE Program Container\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000215864/dsa-2023-247\", \"tags\": [\"vendor-advisory\", \"x_transferred\"]}], \"providerMetadata\": {\"orgId\": \"af854a3a-2127-422b-91ae-364da2661108\", \"shortName\": \"CVE\", \"dateUpdated\": \"2024-08-02T15:18:37.105Z\"}}, {\"title\": \"CISA ADP Vulnrichment\", \"metrics\": [{\"other\": {\"type\": \"ssvc\", \"content\": {\"id\": \"CVE-2023-32446\", \"role\": \"CISA Coordinator\", \"options\": [{\"Exploitation\": \"none\"}, {\"Automatable\": \"no\"}, {\"Technical Impact\": \"partial\"}], \"version\": \"2.0.3\", \"timestamp\": \"2024-10-17T14:09:30.428461Z\"}}}], \"providerMetadata\": {\"orgId\": \"134c704f-9b21-4f2e-91b3-4a467353bcc0\", \"shortName\": \"CISA-ADP\", \"dateUpdated\": \"2024-10-17T14:12:11.049Z\"}}], \"cna\": {\"source\": {\"discovery\": \"UNKNOWN\"}, \"metrics\": [{\"format\": \"CVSS\", \"cvssV3_1\": {\"scope\": \"UNCHANGED\", \"version\": \"3.1\", \"baseScore\": 5.5, \"attackVector\": \"LOCAL\", \"baseSeverity\": \"MEDIUM\", \"vectorString\": \"CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:N/A:N\", \"integrityImpact\": \"NONE\", \"userInteraction\": \"NONE\", \"attackComplexity\": \"LOW\", \"availabilityImpact\": \"NONE\", \"privilegesRequired\": \"LOW\", \"confidentialityImpact\": \"HIGH\"}, \"scenarios\": [{\"lang\": \"en\", \"value\": \"GENERAL\"}]}], \"affected\": [{\"vendor\": \"Dell\", \"product\": \"Wyse Proprietary OS (Modern ThinOS)\", \"versions\": [{\"status\": \"affected\", \"version\": \"2303 (9.4.1141)\"}], \"defaultStatus\": \"unaffected\"}], \"datePublic\": \"2023-07-18T06:30:00.000Z\", \"references\": [{\"url\": \"https://www.dell.com/support/kbdoc/en-us/000215864/dsa-2023-247\", \"tags\": [\"vendor-advisory\"]}], \"x_generator\": {\"engine\": \"Vulnogram 0.1.0-dev\"}, \"descriptions\": [{\"lang\": \"en\", \"value\": \"\\nDell Wyse ThinOS versions prior to 2303 (9.4.1141) contain a sensitive information disclosure vulnerability. An unauthenticated malicious user with local access to the device could exploit this vulnerability to read sensitive information written to the log files.\\n\\n\", \"supportingMedia\": [{\"type\": \"text/html\", \"value\": \"\\n\\n\u003cspan style=\\\"background-color: rgb(255, 255, 255);\\\"\u003eDell Wyse ThinOS versions prior to 2303 (9.4.1141) contain a sensitive information disclosure vulnerability. An unauthenticated malicious user with local access to the device could exploit this vulnerability to read sensitive information written to the log files.\u003c/span\u003e\\n\\n\", \"base64\": false}]}], \"problemTypes\": [{\"descriptions\": [{\"lang\": \"en\", \"type\": \"CWE\", \"cweId\": \"CWE-312\", \"description\": \"CWE-312: Cleartext Storage of Sensitive Information\"}]}], \"providerMetadata\": {\"orgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"shortName\": \"dell\", \"dateUpdated\": \"2023-07-20T12:50:47.946Z\"}}}",
      "cveMetadata": "{\"cveId\": \"CVE-2023-32446\", \"state\": \"PUBLISHED\", \"dateUpdated\": \"2024-10-17T14:12:16.678Z\", \"dateReserved\": \"2023-05-09T06:02:34.290Z\", \"assignerOrgId\": \"c550e75a-17ff-4988-97f0-544cde3820fe\", \"datePublished\": \"2023-07-20T12:50:47.946Z\", \"assignerShortName\": \"dell\"}",
      "dataType": "CVE_RECORD",
      "dataVersion": "5.1"
    }
  }
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…