FKIE_CVE-2023-32619
Vulnerability from fkie_nvd - Published: 2023-09-06 10:15 - Updated: 2024-11-21 08:03
Severity ?
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
8.8 (High) - CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
Archer C50 firmware versions prior to 'Archer C50(JP)_V3_230505' and Archer C55 firmware versions prior to 'Archer C55(JP)_V1_230506' use hard-coded credentials to login to the affected device, which may allow a network-adjacent unauthenticated attacker to execute an arbitrary OS command.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tp-link | archer_c55_firmware | * | |
| tp-link | archer_c55 | - | |
| tp-link | archer_c50_v3_firmware | * | |
| tp-link | archer_c50_v3 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:archer_c55_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4AF28B84-B90E-47B6-B2E8-F78CC909EEC0",
"versionEndExcluding": "230506",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:archer_c55:-:*:*:*:*:*:*:*",
"matchCriteriaId": "1DE7FC0D-0A09-42F6-BA31-597D38208F61",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tp-link:archer_c50_v3_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "7B4081EE-A5EE-41E0-BA3F-39F1BE7799AC",
"versionEndExcluding": "230505",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tp-link:archer_c50_v3:-:*:*:*:*:*:*:*",
"matchCriteriaId": "01EE9C6D-D758-4015-B197-545269BF2283",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Archer C50 firmware versions prior to \u0027Archer C50(JP)_V3_230505\u0027 and Archer C55 firmware versions prior to \u0027Archer C55(JP)_V1_230506\u0027 use hard-coded credentials to login to the affected device, which may allow a network-adjacent unauthenticated attacker to execute an arbitrary OS command."
},
{
"lang": "es",
"value": "Las versiones de firmware de Archer C50 anteriores a \u0027Archer C50(JP)_V3_230505\u0027 y las versiones de firmware de Archer C55 anteriores a \u0027Archer C55(JP)_V1_230506\u0027 utilizan credenciales codificadas para iniciar sesi\u00f3n en el dispositivo afectado, lo que puede permitir que un atacante no autenticado adyacente a la red para ejecutar un comando arbitrario del sistema operativo.\n"
}
],
"id": "CVE-2023-32619",
"lastModified": "2024-11-21T08:03:42.880",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "ADJACENT_NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 8.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:A/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 2.8,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2023-09-06T10:15:13.650",
"references": [
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU99392903/"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Product"
],
"url": "https://www.tp-link.com/jp/support/download/archer-c50/v3/#Firmware"
},
{
"source": "vultures@jpcert.or.jp",
"tags": [
"Product"
],
"url": "https://www.tp-link.com/jp/support/download/archer-c55/#Firmware"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://jvn.jp/en/vu/JVNVU99392903/"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Product"
],
"url": "https://www.tp-link.com/jp/support/download/archer-c50/v3/#Firmware"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Product"
],
"url": "https://www.tp-link.com/jp/support/download/archer-c55/#Firmware"
}
],
"sourceIdentifier": "vultures@jpcert.or.jp",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-798"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…