FKIE_CVE-2023-33218
Vulnerability from fkie_nvd - Published: 2023-12-15 12:15 - Updated: 2024-11-21 08:05
Severity ?
9.1 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
The Parameter Zone Read and Parameter Zone Write command handlers allow performing a Stack buffer overflow.
This could potentially lead to a Remote Code execution on the targeted device.
References
Impacted products
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:idemia:sigma_lite_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "983A7DAD-1995-4A8A-8714-D47D4E90ABF2",
"versionEndExcluding": "4.15.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:idemia:sigma_lite:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E2F8847F-E51A-4A64-A2D4-FCDD193E7AFA",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:idemia:sigma_lite\\+_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A2582E12-D19F-4660-A98C-6941C8C9081D",
"versionEndExcluding": "4.15.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:idemia:sigma_lite\\+:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2BB49653-25EA-4F69-A1B7-0ACA58F85FF1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:idemia:sigma_extreme_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "865DE0C9-5384-45BD-AF81-5C416FCB962A",
"versionEndExcluding": "4.15.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:idemia:sigma_extreme:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4FB05B6D-7D4C-4148-A05A-751B272B0E25",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:idemia:sigma_wide_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8E2D74C2-6C83-4111-B410-E81C7414309B",
"versionEndExcluding": "4.15.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:idemia:sigma_wide:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BE86F813-6021-4FEB-86A9-B7013EEB4416",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:idemia:morphowave_compact_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "8BDA2ED3-4875-45EB-8489-8C6B8F44EF2A",
"versionEndExcluding": "2.12.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:idemia:morphowave_compact:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B36E662E-C713-47E5-B07E-F0D9F1C63E9D",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:idemia:morphowave_xp_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "AEAD097B-E5A8-492F-9ABB-75D5D15A8F9F",
"versionEndExcluding": "2.12.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:idemia:morphowave_xp:-:*:*:*:*:*:*:*",
"matchCriteriaId": "2FA7252B-5871-4A13-B41D-752A5EA276F1",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:idemia:visionpass_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "1ED8DCF7-F85C-4513-BF69-5FE2D7185A96",
"versionEndExcluding": "2.12.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:idemia:visionpass:-:*:*:*:*:*:*:*",
"matchCriteriaId": "CDABE653-294E-478C-B458-F9A1206A0E7E",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:idemia:morphowave_sp_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "BF554F0F-8E5D-40A2-A676-8984AB685CEE",
"versionEndExcluding": "1.2.7",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:idemia:morphowave_sp:-:*:*:*:*:*:*:*",
"matchCriteriaId": "AFD369B0-119B-497B-9353-AB5E5E267FF9",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "\n\n\nThe Parameter Zone Read and Parameter Zone Write command handlers allow performing a Stack buffer overflow. \nThis could potentially lead to a Remote Code execution on the targeted device.\n\n"
},
{
"lang": "es",
"value": "Los controladores de comandos Parameter Zone Read and Parameter Zone Write permiten realizar un desbordamiento del b\u00fafer de pila. Potencialmente, esto podr\u00eda conducir a la ejecuci\u00f3n de un c\u00f3digo remoto en el dispositivo de destino."
}
],
"id": "CVE-2023-33218",
"lastModified": "2024-11-21T08:05:09.527",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "NONE",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:N",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.2,
"source": "a87f365f-9d39-4848-9b3a-58c7cae69cab",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2023-12-15T12:15:43.317",
"references": [
{
"source": "a87f365f-9d39-4848-9b3a-58c7cae69cab",
"tags": [
"Vendor Advisory"
],
"url": "https://www.idemia.com/wp-content/uploads/2023/11/Security-Advisory-SA-2023-05-2.pdf"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://www.idemia.com/wp-content/uploads/2023/11/Security-Advisory-SA-2023-05-2.pdf"
}
],
"sourceIdentifier": "a87f365f-9d39-4848-9b3a-58c7cae69cab",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "a87f365f-9d39-4848-9b3a-58c7cae69cab",
"type": "Secondary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-787"
}
],
"source": "nvd@nist.gov",
"type": "Primary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…