GCVE Workshop - 22 September 2026 (14:00-18:00), Luxembourg Before The Vulnopticon Conference - Registration

FKIE_CVE-2023-43623

Vulnerability from fkie_nvd - Published: 2023-10-10 11:15 - Updated: 2026-06-17 06:26
Summary
A vulnerability has been identified in Mendix Forgot Password (Mendix 10 compatible) (All versions < V5.4.0), Mendix Forgot Password (Mendix 7 compatible) (All versions < V3.7.3), Mendix Forgot Password (Mendix 8 compatible) (All versions < V4.1.3), Mendix Forgot Password (Mendix 9 compatible) (All versions < V5.4.0). Applications using the affected module are vulnerable to user enumeration due to distinguishable responses. This could allow an unauthenticated remote attacker to determine if a user is valid or not, enabling a brute force attack with valid users.
Impacted products

{
  "affected": [
    {
      "affectedData": [
        {
          "defaultStatus": "unknown",
          "product": "Mendix Forgot Password (Mendix 10 compatible)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.4.0"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Forgot Password (Mendix 7 compatible)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V3.7.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Forgot Password (Mendix 8 compatible)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V4.1.3"
            }
          ]
        },
        {
          "defaultStatus": "unknown",
          "product": "Mendix Forgot Password (Mendix 9 compatible)",
          "vendor": "Siemens",
          "versions": [
            {
              "status": "affected",
              "version": "All versions \u003c V5.4.0"
            }
          ]
        }
      ],
      "source": "productcert@siemens.com"
    }
  ],
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:mendix:forgot_password:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "A4841C81-BDB6-4D19-9399-25E106AF654B",
              "versionEndExcluding": "3.7.3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mendix:forgot_password:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "4D6E5A35-E9FB-4F42-8022-605EE691C0B6",
              "versionEndExcluding": "4.1.3",
              "versionStartIncluding": "4.0.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:mendix:forgot_password:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "B5D68BE8-7D5E-4FFF-A1B6-E9ECA060BCEC",
              "versionEndExcluding": "5.4.0",
              "versionStartIncluding": "5.0.0",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in Mendix Forgot Password (Mendix 10 compatible) (All versions \u003c V5.4.0), Mendix Forgot Password (Mendix 7 compatible) (All versions \u003c V3.7.3), Mendix Forgot Password (Mendix 8 compatible) (All versions \u003c V4.1.3), Mendix Forgot Password (Mendix 9 compatible) (All versions \u003c V5.4.0). Applications using the affected module are vulnerable to user enumeration due to distinguishable responses. This could allow an unauthenticated remote attacker to determine if a user is valid or not, enabling a brute force attack with valid users."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en: \nMendix Forgot Password (compatible con Mendix 10) (todas las versiones \u0026lt; V5.4.0), \nMendix Forgot Password (compatible con Mendix 7) (todas las versiones \u0026lt; V3.7.3), \nMendix Forgot Password (compatible con Mendix 8) (Todas versiones \u0026lt; V4.1.3),\nMendix Forgot Password (compatible con Mendix 9) (Todas las versiones \u0026lt; V5.4.0). \nLas aplicaciones que utilizan el m\u00f3dulo afectado son vulnerables a la enumeraci\u00f3n de usuarios debido a respuestas distinguibles. Esto podr\u00eda permitir que un atacante remoto no autenticado determine si un usuario es v\u00e1lido o no, permitiendo un ataque de fuerza bruta con usuarios v\u00e1lidos."
    }
  ],
  "id": "CVE-2023-43623",
  "lastModified": "2026-06-17T06:26:05.600",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "NONE",
          "baseScore": 5.3,
          "baseSeverity": "MEDIUM",
          "confidentialityImpact": "LOW",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:L/I:N/A:N",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 1.4,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2023-43623",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "yes"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2024-09-18T18:49:24.540753Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2023-10-10T11:15:12.240",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-295483.pdf"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/pdf/ssa-295483.pdf"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Modified",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-203"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…