FKIE_CVE-2023-51584

Vulnerability from fkie_nvd - Published: 2024-05-03 03:16 - Updated: 2025-07-09 16:59
Summary
Voltronic Power ViewPower USBCommEx shutdown Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Voltronic Power ViewPower Pro. User interaction is required to exploit this vulnerability in that an administrator must trigger a shutdown operation. The specific flaw exists within the shutdown method. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22065.
Impacted products
Vendor Product Version
voltronicpower viewpower 1.04.21353

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:voltronicpower:viewpower:1.04.21353:*:*:*:-:*:*:*",
              "matchCriteriaId": "2CE4A520-86B5-4AE3-AD0E-7744328090E4",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Voltronic Power ViewPower USBCommEx shutdown Exposed Dangerous Method Remote Code Execution Vulnerability. This vulnerability allows remote attackers to execute arbitrary code on affected installations of Voltronic Power ViewPower Pro. User interaction is required to exploit this vulnerability in that an administrator must trigger a shutdown operation.\n\nThe specific flaw exists within the shutdown method. The issue results from an exposed dangerous method. An attacker can leverage this vulnerability to execute code in the context of the current user. Was ZDI-CAN-22065."
    },
    {
      "lang": "es",
      "value": "Apagado de Voltronic Power ViewPower USBCommEx Vulnerabilidad de ejecuci\u00f3n remota de c\u00f3digo de m\u00e9todo peligroso expuesto. Esta vulnerabilidad permite a atacantes remotos ejecutar c\u00f3digo arbitrario en instalaciones afectadas de Voltronic Power ViewPower Pro. Se requiere la interacci\u00f3n del usuario para aprovechar esta vulnerabilidad, ya que un administrador debe activar una operaci\u00f3n de apagado. La falla espec\u00edfica existe dentro del m\u00e9todo de apagado. El problema se debe a un m\u00e9todo peligroso expuesto. Un atacante puede aprovechar esta vulnerabilidad para ejecutar c\u00f3digo en el contexto del usuario actual. Era ZDI-CAN-22065."
    }
  ],
  "id": "CVE-2023-51584",
  "lastModified": "2025-07-09T16:59:02.530",
  "metrics": {
    "cvssMetricV30": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 8.8,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.0/AV:N/AC:L/PR:N/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.0"
        },
        "exploitabilityScore": 2.8,
        "impactScore": 5.9,
        "source": "zdi-disclosures@trendmicro.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2024-05-03T03:16:18.377",
  "references": [
    {
      "source": "zdi-disclosures@trendmicro.com",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1889/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "tags": [
        "Third Party Advisory"
      ],
      "url": "https://www.zerodayinitiative.com/advisories/ZDI-23-1889/"
    }
  ],
  "sourceIdentifier": "zdi-disclosures@trendmicro.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-749"
        }
      ],
      "source": "zdi-disclosures@trendmicro.com",
      "type": "Secondary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…