FKIE_CVE-2024-0925
Vulnerability from fkie_nvd - Published: 2024-01-26 15:15 - Updated: 2024-11-21 08:47
Severity ?
4.7 (Medium) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
9.8 (Critical) - CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H
Summary
A vulnerability has been found in Tenda AC10U 15.03.06.49_multi_TDE01 and classified as critical. This vulnerability affects the function formSetVirtualSer. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-252130 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way.
References
| URL | Tags | ||
|---|---|---|---|
| cna@vuldb.com | https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/formSetVirtualSer.md | Exploit, Third Party Advisory | |
| cna@vuldb.com | https://vuldb.com/?ctiid.252130 | Permissions Required, Third Party Advisory | |
| cna@vuldb.com | https://vuldb.com/?id.252130 | Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/formSetVirtualSer.md | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?ctiid.252130 | Permissions Required, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://vuldb.com/?id.252130 | Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| tendacn | ac10u_firmware | 15.03.06.49_multi_tde01 | |
| tendacn | ac10u | 1.0 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:tendacn:ac10u_firmware:15.03.06.49_multi_tde01:*:*:*:*:*:*:*",
"matchCriteriaId": "D1C36BB3-509E-4120-B2EC-F4D061A71F2A",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:tendacn:ac10u:1.0:*:*:*:*:*:*:*",
"matchCriteriaId": "BFF286BB-A1D3-4E51-AB31-B5A531A8B440",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A vulnerability has been found in Tenda AC10U 15.03.06.49_multi_TDE01 and classified as critical. This vulnerability affects the function formSetVirtualSer. The manipulation of the argument list leads to stack-based buffer overflow. The attack can be initiated remotely. The exploit has been disclosed to the public and may be used. VDB-252130 is the identifier assigned to this vulnerability. NOTE: The vendor was contacted early about this disclosure but did not respond in any way."
},
{
"lang": "es",
"value": "Una vulnerabilidad ha sido encontrada en Tenda AC10U 15.03.06.49_multi_TDE01 y clasificada como cr\u00edtica. Esta vulnerabilidad afecta a la funci\u00f3n formSetVirtualSer. La manipulaci\u00f3n del argumento list provoca un desbordamiento de b\u00fafer en la regi\u00f3n stack de la memoria. El ataque se puede iniciar de forma remota. La explotaci\u00f3n ha sido divulgada al p\u00fablico y puede utilizarse. VDB-252130 es el identificador asignado a esta vulnerabilidad. NOTA: Se contact\u00f3 primeramente con proveedor sobre esta divulgaci\u00f3n, pero no respondi\u00f3 de ninguna manera."
}
],
"id": "CVE-2024-0925",
"lastModified": "2024-11-21T08:47:45.800",
"metrics": {
"cvssMetricV2": [
{
"acInsufInfo": false,
"baseSeverity": "MEDIUM",
"cvssData": {
"accessComplexity": "LOW",
"accessVector": "NETWORK",
"authentication": "MULTIPLE",
"availabilityImpact": "PARTIAL",
"baseScore": 5.8,
"confidentialityImpact": "PARTIAL",
"integrityImpact": "PARTIAL",
"vectorString": "AV:N/AC:L/Au:M/C:P/I:P/A:P",
"version": "2.0"
},
"exploitabilityScore": 6.4,
"impactScore": 6.4,
"obtainAllPrivilege": false,
"obtainOtherPrivilege": false,
"obtainUserPrivilege": false,
"source": "cna@vuldb.com",
"type": "Secondary",
"userInteractionRequired": false
}
],
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "LOW",
"baseScore": 4.7,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "LOW",
"integrityImpact": "LOW",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:L/I:L/A:L",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 3.4,
"source": "cna@vuldb.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.8,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2024-01-26T15:15:08.770",
"references": [
{
"source": "cna@vuldb.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/formSetVirtualSer.md"
},
{
"source": "cna@vuldb.com",
"tags": [
"Permissions Required",
"Third Party Advisory"
],
"url": "https://vuldb.com/?ctiid.252130"
},
{
"source": "cna@vuldb.com",
"tags": [
"Third Party Advisory"
],
"url": "https://vuldb.com/?id.252130"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://github.com/yaoyue123/iot/blob/main/Tenda/AC10U/formSetVirtualSer.md"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Permissions Required",
"Third Party Advisory"
],
"url": "https://vuldb.com/?ctiid.252130"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Third Party Advisory"
],
"url": "https://vuldb.com/?id.252130"
}
],
"sourceIdentifier": "cna@vuldb.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-121"
}
],
"source": "cna@vuldb.com",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…