FKIE_CVE-2024-22187
Vulnerability from fkie_nvd - Published: 2024-05-28 16:15 - Updated: 2025-02-12 17:30
Severity ?
Summary
A write-what-where vulnerability exists in the Programming Software Connection Remote Memory Diagnostics functionality of AutomationDirect P3-550E 1.2.10.9. A specially crafted network packet can lead to an arbitrary write. An attacker can send an unauthenticated packet to trigger this vulnerability.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| automationdirect | p3-550e_firmware | 1.2.10.9 | |
| automationdirect | p3-550e_firmware | 4.1.1.10 | |
| automationdirect | p3-550e | - | |
| automationdirect | p3-550_firmware | 1.2.10.9 | |
| automationdirect | p3-550_firmware | 4.1.1.10 | |
| automationdirect | p3-550 | - | |
| automationdirect | p3-530_firmware | 1.2.10.9 | |
| automationdirect | p3-530_firmware | 4.1.1.10 | |
| automationdirect | p3-530 | - | |
| automationdirect | p2-550_firmware | 1.2.10.10 | |
| automationdirect | p2-550_firmware | 4.1.1.10 | |
| automationdirect | p2-550 | - | |
| automationdirect | p1-550_firmware | 1.2.10.10 | |
| automationdirect | p1-550_firmware | 4.1.1.10 | |
| automationdirect | p1-550 | - | |
| automationdirect | p1-540_firmware | 1.2.10.10 | |
| automationdirect | p1-540_firmware | 4.1.1.10 | |
| automationdirect | p1-540 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:automationdirect:p3-550e_firmware:1.2.10.9:*:*:*:*:*:*:*",
"matchCriteriaId": "4A393F14-3BD3-44DE-B06F-9235AB62C68F",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:automationdirect:p3-550e_firmware:4.1.1.10:*:*:*:*:*:*:*",
"matchCriteriaId": "5A4772E7-8788-4DB5-98CE-25F0255E0386",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:automationdirect:p3-550e:-:*:*:*:*:*:*:*",
"matchCriteriaId": "5086EF1F-C3CE-4B5F-A352-67CE332A6C4F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:automationdirect:p3-550_firmware:1.2.10.9:*:*:*:*:*:*:*",
"matchCriteriaId": "CC227F17-D280-4C74-A73E-8F92158686BE",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:automationdirect:p3-550_firmware:4.1.1.10:*:*:*:*:*:*:*",
"matchCriteriaId": "5CC4A2E2-DF6D-427A-88E6-54FD6D11BDFC",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:automationdirect:p3-550:-:*:*:*:*:*:*:*",
"matchCriteriaId": "BB4DDF3B-AB0E-4DDD-9865-D4EEDCCA78DE",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:automationdirect:p3-530_firmware:1.2.10.9:*:*:*:*:*:*:*",
"matchCriteriaId": "0462A9CE-4EAA-4C12-9147-F530C42328D3",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:automationdirect:p3-530_firmware:4.1.1.10:*:*:*:*:*:*:*",
"matchCriteriaId": "C8277A48-94C7-40F3-A822-F6311B2CDA94",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:automationdirect:p3-530:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D58D4140-C719-4EDA-8963-667F9FF21970",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:automationdirect:p2-550_firmware:1.2.10.10:*:*:*:*:*:*:*",
"matchCriteriaId": "AAF96AFD-40E3-4FB6-BAD7-067D9E257A08",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:automationdirect:p2-550_firmware:4.1.1.10:*:*:*:*:*:*:*",
"matchCriteriaId": "D476CC45-B4A1-4210-9347-9854BB0A86AA",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:automationdirect:p2-550:-:*:*:*:*:*:*:*",
"matchCriteriaId": "386D70E8-70D6-4D25-818C-2218E1B1AC6C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:automationdirect:p1-550_firmware:1.2.10.10:*:*:*:*:*:*:*",
"matchCriteriaId": "9B7F3A1F-BD96-49A7-A340-0E5E1893326C",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:automationdirect:p1-550_firmware:4.1.1.10:*:*:*:*:*:*:*",
"matchCriteriaId": "27710A58-507C-43BB-849F-7238F5D6D9ED",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:automationdirect:p1-550:-:*:*:*:*:*:*:*",
"matchCriteriaId": "8FAF2C99-BC5F-4E99-A3A8-FBBDDC24C933",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:automationdirect:p1-540_firmware:1.2.10.10:*:*:*:*:*:*:*",
"matchCriteriaId": "01C6DFFC-374B-4314-9230-53BD01BD6574",
"vulnerable": true
},
{
"criteria": "cpe:2.3:o:automationdirect:p1-540_firmware:4.1.1.10:*:*:*:*:*:*:*",
"matchCriteriaId": "51095762-A87C-4A1D-A4E2-679462DC8FA9",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:automationdirect:p1-540:-:*:*:*:*:*:*:*",
"matchCriteriaId": "4DB6B9FC-390E-43FD-9DF9-AAB1A9CDAA48",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A write-what-where vulnerability exists in the Programming Software Connection Remote Memory Diagnostics functionality of AutomationDirect P3-550E 1.2.10.9. A specially crafted network packet can lead to an arbitrary write. An attacker can send an unauthenticated packet to trigger this vulnerability."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de escritura en qu\u00e9 lugar en la funcionalidad de diagn\u00f3stico de memoria remota de conexi\u00f3n de software de programaci\u00f3n de AutomationDirect P3-550E 1.2.10.9. Un paquete de red especialmente manipulado puede provocar una escritura arbitraria. Un atacante puede enviar un paquete no autenticado para desencadenar esta vulnerabilidad."
}
],
"id": "CVE-2024-22187",
"lastModified": "2025-02-12T17:30:21.533",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 9.1,
"baseSeverity": "CRITICAL",
"confidentialityImpact": "NONE",
"integrityImpact": "HIGH",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 5.2,
"source": "talos-cna@cisco.com",
"type": "Primary"
}
]
},
"published": "2024-05-28T16:15:12.330",
"references": [
{
"source": "talos-cna@cisco.com",
"tags": [
"Vendor Advisory"
],
"url": "https://community.automationdirect.com/s/internal-database-security-advisory/a4GPE0000003yXV2AY/sa00036"
},
{
"source": "talos-cna@cisco.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-1940"
},
{
"source": "talos-cna@cisco.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2024-1940"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Vendor Advisory"
],
"url": "https://community.automationdirect.com/s/internal-database-security-advisory/a4GPE0000003yXV2AY/sa00036"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://talosintelligence.com/vulnerability_reports/TALOS-2024-1940"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.talosintelligence.com/vulnerability_reports/TALOS-2024-1940"
}
],
"sourceIdentifier": "talos-cna@cisco.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-284"
}
],
"source": "talos-cna@cisco.com",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "NVD-CWE-Other"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…