FKIE_CVE-2024-41153
Vulnerability from fkie_nvd - Published: 2024-10-29 13:15 - Updated: 2025-10-24 09:15
Severity ?
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
7.2 (High) - CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H
Summary
Command injection vulnerability in the Edge Computing UI for the
TRO600 series radios that allows for the execution of arbitrary system commands. If exploited, an attacker with write access to the
web UI can execute commands on the device with root privileges,
far more extensive than what the write privilege intends.
References
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| hitachienergy | tro610_firmware | * | |
| hitachienergy | tro610 | - | |
| hitachienergy | tro620_firmware | * | |
| hitachienergy | tro620 | - | |
| hitachienergy | tro670_firmware | * | |
| hitachienergy | tro670 | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hitachienergy:tro610_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "D5C2D2E0-5383-44E5-B8C6-C743503A8E51",
"versionEndExcluding": "9.2.0.5",
"versionStartIncluding": "9.1.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hitachienergy:tro610:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B3A46C6E-9314-40EB-A8BE-0D3A26B5FE4C",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hitachienergy:tro620_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "4BE01813-8087-4E9B-8B2B-FF813C0E9506",
"versionEndExcluding": "9.2.0.5",
"versionStartIncluding": "9.1.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hitachienergy:tro620:-:*:*:*:*:*:*:*",
"matchCriteriaId": "DC979E74-6316-4BED-87A6-4DC9B9747E0F",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:hitachienergy:tro670_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "A6A94F87-2875-46C9-8BD3-BE3EA9F71648",
"versionEndExcluding": "9.2.0.5",
"versionStartIncluding": "9.1.0.0",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:hitachienergy:tro670:-:*:*:*:*:*:*:*",
"matchCriteriaId": "E84F6910-1D58-4AE7-94EF-797C9BD52690",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Command injection vulnerability in the Edge Computing UI for the\nTRO600 series radios that allows for the execution of arbitrary system commands. If exploited, an attacker with write access to the\nweb UI can execute commands on the device with root privileges,\nfar more extensive than what the write privilege intends."
},
{
"lang": "es",
"value": "Vulnerabilidad de inyecci\u00f3n de comandos en la interfaz de usuario de Edge Computing para las radios de la serie TRO600 que permite la ejecuci\u00f3n de comandos arbitrarios del sistema. Si se explota, un atacante con acceso de escritura a la interfaz de usuario web puede ejecutar comandos en el dispositivo con privilegios de root, mucho m\u00e1s amplios que los que pretende el privilegio de escritura."
}
],
"id": "CVE-2024-41153",
"lastModified": "2025-10-24T09:15:39.647",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "cybersecurity@hitachienergy.com",
"type": "Secondary"
},
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "nvd@nist.gov",
"type": "Primary"
}
]
},
"published": "2024-10-29T13:15:04.600",
"references": [
{
"source": "cybersecurity@hitachienergy.com",
"tags": [
"Vendor Advisory"
],
"url": "https://publisher.hitachienergy.com/preview?DocumentID=8DBD000147\u0026LanguageCode=en\u0026DocumentPartId=\u0026Action=launch"
}
],
"sourceIdentifier": "cybersecurity@hitachienergy.com",
"vulnStatus": "Modified",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "cybersecurity@hitachienergy.com",
"type": "Primary"
},
{
"description": [
{
"lang": "en",
"value": "CWE-77"
}
],
"source": "nvd@nist.gov",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…