FKIE_CVE-2024-4549
Vulnerability from fkie_nvd - Published: 2024-05-06 14:15 - Updated: 2025-06-17 16:24
Severity ?
Summary
A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. When processing an 'ICS Restart!' message, CEBC.exe restarts the system.
References
| URL | Tags | ||
|---|---|---|---|
| vulnreport@tenable.com | https://www.tenable.com/security/research/tra-2024-13 | Exploit, Third Party Advisory | |
| af854a3a-2127-422b-91ae-364da2661108 | https://www.tenable.com/security/research/tra-2024-13 | Exploit, Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| deltaww | diaenergie | * |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:deltaww:diaenergie:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B246D713-39D0-4794-8C3E-EE51B11202BF",
"versionEndExcluding": "1.10.01.004",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A denial of service vulnerability exists in Delta Electronics DIAEnergie v1.10.1.8610 and prior. When processing an \u0027ICS Restart!\u0027 message, CEBC.exe restarts the system."
},
{
"lang": "es",
"value": "Existe una vulnerabilidad de denegaci\u00f3n de servicio en Delta Electronics DIAEnergie v1.10.1.8610 y anteriores. Al procesar un mensaje \u0027ICS Restart!, CEBC.exe reinicia el sistema."
}
],
"id": "CVE-2024-4549",
"lastModified": "2025-06-17T16:24:54.557",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.5,
"baseSeverity": "HIGH",
"confidentialityImpact": "NONE",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
"version": "3.1"
},
"exploitabilityScore": 3.9,
"impactScore": 3.6,
"source": "vulnreport@tenable.com",
"type": "Secondary"
}
]
},
"published": "2024-05-06T14:15:08.717",
"references": [
{
"source": "vulnreport@tenable.com",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2024-13"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"tags": [
"Exploit",
"Third Party Advisory"
],
"url": "https://www.tenable.com/security/research/tra-2024-13"
}
],
"sourceIdentifier": "vulnreport@tenable.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-400"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…