FKIE_CVE-2024-50364
Vulnerability from fkie_nvd - Published: 2024-11-26 11:22 - Updated: 2026-01-23 19:37
Severity ?
Summary
A CWE-78 "Improper Neutralization of Special Elements used in an OS Command ('OS Command Injection')" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (<= 1.6.3), EKI-6333AC-2GD (<= v1.6.3) and EKI-6333AC-1GPO (<= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the "export_log" API which are not properly sanitized before being concatenated to OS level commands.
References
| URL | Tags | ||
|---|---|---|---|
| prodsec@nozominetworks.com | https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50364 | Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| advantech | eki-6333ac-2g_firmware | * | |
| advantech | eki-6333ac-2g | - | |
| advantech | eki-6333ac-2gd_firmware | * | |
| advantech | eki-6333ac-2gd | - | |
| advantech | eki-6333ac-1gpo_firmware | * | |
| advantech | eki-6333ac-1gpo | - |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:advantech:eki-6333ac-2g_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "B5E027C8-2521-45FC-BABB-4A6E3341F883",
"versionEndExcluding": "1.6.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:advantech:eki-6333ac-2g:-:*:*:*:*:*:*:*",
"matchCriteriaId": "B3B63DF4-0184-4108-B48B-D31179104701",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:advantech:eki-6333ac-2gd_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "447F8AEB-2C7C-411A-893C-11C2F7588C82",
"versionEndExcluding": "1.6.5",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:advantech:eki-6333ac-2gd:-:*:*:*:*:*:*:*",
"matchCriteriaId": "02F70DBA-2D4C-4407-885D-71887A1A7979",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
},
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:o:advantech:eki-6333ac-1gpo_firmware:*:*:*:*:*:*:*:*",
"matchCriteriaId": "828B9D05-0064-4690-A624-D3BF659BD316",
"versionEndExcluding": "1.2.2",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
},
{
"cpeMatch": [
{
"criteria": "cpe:2.3:h:advantech:eki-6333ac-1gpo:-:*:*:*:*:*:*:*",
"matchCriteriaId": "D2A73A2B-9FD5-4971-8FFF-1BA14BCCB37B",
"vulnerable": false
}
],
"negate": false,
"operator": "OR"
}
],
"operator": "AND"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "A CWE-78 \"Improper Neutralization of Special Elements used in an OS Command (\u0027OS Command Injection\u0027)\" was discovered affecting the following devices manufactured by Advantech: EKI-6333AC-2G (\u003c= 1.6.3), EKI-6333AC-2GD (\u003c= v1.6.3) and EKI-6333AC-1GPO (\u003c= v1.2.1). The source of the vulnerability relies on multiple parameters belonging to the \"export_log\" API which are not properly sanitized before being concatenated to OS level commands."
},
{
"lang": "es",
"value": "Se descubri\u00f3 una vulnerabilidad CWE-78 \"Neutralizaci\u00f3n incorrecta de elementos especiales utilizados en un comando del SO (\u0027Inyecci\u00f3n de comando del SO\u0027)\" que afecta a los siguientes dispositivos fabricados por Advantech: EKI-6333AC-2G (\u0026lt;= 1.6.3), EKI-6333AC-2GD (\u0026lt;= v1.6.3) y EKI-6333AC-1GPO (\u0026lt;= v1.2.1). La fuente de la vulnerabilidad se basa en m\u00faltiples par\u00e1metros pertenecientes a la API \"export_log\" que no se desinfectan correctamente antes de concatenarse con comandos de nivel del SO."
}
],
"id": "CVE-2024-50364",
"lastModified": "2026-01-23T19:37:41.653",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "prodsec@nozominetworks.com",
"type": "Secondary"
}
]
},
"published": "2024-11-26T11:22:02.973",
"references": [
{
"source": "prodsec@nozominetworks.com",
"tags": [
"Third Party Advisory"
],
"url": "https://www.nozominetworks.com/labs/vulnerability-advisories-cve-2024-50364"
}
],
"sourceIdentifier": "prodsec@nozominetworks.com",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-78"
}
],
"source": "prodsec@nozominetworks.com",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…