FKIE_CVE-2024-5631

Vulnerability from fkie_nvd - Published: 2024-07-09 11:15 - Updated: 2026-06-17 08:16
Summary
Longse NVR (Network Video Recorder) model NVR3608PGE2W, as well as products based on this device, are transmitting user's login and password to a remote control service without using any encryption. This enables an on-path attacker to eavesdrop the credentials and subsequently obtain access to the video stream.  The credentials are being sent when a user decides to change his password in router's portal.
Impacted products
Vendor Product Version

{
  "affected": [
    {
      "affectedData": [
        {
          "defaultStatus": "affected",
          "product": "NVR3608PGE2W",
          "vendor": "Longse Technology",
          "versions": [
            {
              "lessThanOrEqual": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        },
        {
          "defaultStatus": "affected",
          "product": "ZMB-01",
          "vendor": "Zamel",
          "versions": [
            {
              "lessThanOrEqual": "*",
              "status": "affected",
              "version": "0",
              "versionType": "custom"
            }
          ]
        }
      ],
      "source": "cvd@cert.pl"
    }
  ],
  "cveTags": [
    {
      "sourceIdentifier": "cvd@cert.pl",
      "tags": [
        "unsupported-when-assigned"
      ]
    }
  ],
  "descriptions": [
    {
      "lang": "en",
      "value": "Longse NVR (Network Video Recorder) model\u00a0NVR3608PGE2W, as well as products based on this device, are transmitting user\u0027s login and password to a remote control service without using any encryption. This enables an on-path attacker to eavesdrop the credentials and subsequently obtain access to the video stream.\u00a0\nThe credentials are being sent when a user decides to change his password in router\u0027s portal."
    },
    {
      "lang": "es",
      "value": " Longse NVR (Network Video Recorder) modelo NVR3608PGE2W, as\u00ed como los productos basados en este dispositivo, transmiten el nombre de usuario y la contrase\u00f1a a un servicio de control remoto sin utilizar ning\u00fan cifrado. Esto permite a un atacante en ruta espiar las credenciales y posteriormente obtener acceso a la transmisi\u00f3n de video. Las credenciales se env\u00edan cuando un usuario decide cambiar su contrase\u00f1a en el portal del enrutador."
    }
  ],
  "id": "CVE-2024-5631",
  "lastModified": "2026-06-17T08:16:19.483",
  "metrics": {
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "PRESENT",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 6.0,
          "baseSeverity": "MEDIUM",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "PASSIVE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:P/PR:N/UI:P/VC:H/VI:N/VA:N/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "NONE",
          "vulnConfidentialityImpact": "HIGH",
          "vulnIntegrityImpact": "NONE",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "cvd@cert.pl",
        "type": "Secondary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2024-5631",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "partial"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2024-07-09T15:12:14.314814Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2024-07-09T11:15:15.740",
  "references": [
    {
      "source": "cvd@cert.pl",
      "url": "https://cert.pl/en/posts/2024/07/CVE-2024-5631/"
    },
    {
      "source": "cvd@cert.pl",
      "url": "https://cert.pl/posts/2024/07/CVE-2024-5631"
    },
    {
      "source": "cvd@cert.pl",
      "url": "https://zamel.com/pl/gardi/zestaw-monitoringu-bezprzewodowego-wi-fi-typ-zmb-01"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert.pl/en/posts/2024/07/CVE-2024-5631/"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://cert.pl/posts/2024/07/CVE-2024-5631"
    },
    {
      "source": "af854a3a-2127-422b-91ae-364da2661108",
      "url": "https://zamel.com/pl/gardi/zestaw-monitoringu-bezprzewodowego-wi-fi-typ-zmb-01"
    }
  ],
  "sourceIdentifier": "cvd@cert.pl",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-319"
        }
      ],
      "source": "cvd@cert.pl",
      "type": "Secondary"
    }
  ]
}



Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Loading…

Loading…

Related by attack behaviour

Vulnerabilities whose description is nearest to this one in the vector space of the CIRCL/vulnerability-attack-technique-biencoder model. This is a similarity search over the bi-encoder space (plain cosine), not a classification, and it has no measured accuracy.


Loading…