FKIE_CVE-2025-14265

Vulnerability from fkie_nvd - Published: 2025-12-11 15:15 - Updated: 2025-12-12 15:18
Severity ?
Summary
In versions of ScreenConnect™ prior to 25.8, server-side validation and integrity checks within the extension subsystem could allow the installation and execution of untrusted or arbitrary extensions by authorized or administrative users. Abuse of this behavior could result in the execution of custom code on the server or unauthorized access to application configuration data. This issue affects only the ScreenConnect server component; host and guest clients are not impacted. ScreenConnect 25.8 introduces enhanced server-side configuration handling and integrity checks to ensure only trusted extensions can be installed.
Impacted products
Vendor Product Version

{
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "In versions of ScreenConnect\u2122 prior to 25.8, server-side validation and integrity checks within the extension subsystem could allow the installation and execution of untrusted or arbitrary extensions by authorized or administrative users. Abuse of this behavior could result in the execution of custom code on the server or unauthorized access to application configuration data. This issue affects only the ScreenConnect server component; host and guest clients are not impacted. ScreenConnect 25.8 introduces enhanced server-side configuration handling and integrity checks to ensure only trusted extensions can be installed."
    }
  ],
  "id": "CVE-2025-14265",
  "lastModified": "2025-12-12T15:18:13.390",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 9.1,
          "baseSeverity": "CRITICAL",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "HIGH",
          "scope": "CHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 2.3,
        "impactScore": 6.0,
        "source": "7d616e1a-3288-43b1-a0dd-0a65d3e70a49",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-12-11T15:15:46.863",
  "references": [
    {
      "source": "7d616e1a-3288-43b1-a0dd-0a65d3e70a49",
      "url": "https://www.connectwise.com/company/trust/security-bulletins/screenconnect-2025.8-security-patch"
    }
  ],
  "sourceIdentifier": "7d616e1a-3288-43b1-a0dd-0a65d3e70a49",
  "vulnStatus": "Awaiting Analysis",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-494"
        }
      ],
      "source": "7d616e1a-3288-43b1-a0dd-0a65d3e70a49",
      "type": "Secondary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…