FKIE_CVE-2025-30175

Vulnerability from fkie_nvd - Published: 2025-05-13 10:15 - Updated: 2025-10-03 19:52
Summary
A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions < V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions < V2.15.1.1). Affected products contain a out of bound write buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition.

{
  "configurations": [
    {
      "nodes": [
        {
          "cpeMatch": [
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:4.1:*:*:*:*:*:*:*",
              "matchCriteriaId": "3F0A4753-2049-4462-BE3C-78E60548E144",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:simatic_pcs_neo:5.0:*:*:*:*:*:*:*",
              "matchCriteriaId": "03D9BFA4-6205-483C-A3C9-AB708BF2FDDA",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinec_nms:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "7B9143A8-0ED9-467A-9138-2D2CCB9ADC84",
              "versionEndExcluding": "4.0",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:sinema_remote_connect:-:*:*:*:*:*:*:*",
              "matchCriteriaId": "9646F056-080A-4F45-AABD-4D6E8AF05148",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:17:*:*:*:*:*:*:*",
              "matchCriteriaId": "7E0C3283-1FEA-4054-9D48-5F683FA9E4FF",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:18:*:*:*:*:*:*:*",
              "matchCriteriaId": "68C7D9A3-9304-4A81-A970-717E5BA1ECF1",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:19:*:*:*:*:*:*:*",
              "matchCriteriaId": "CCFAD019-787A-40C7-919B-9780B37B05E3",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:totally_integrated_automation_portal:20:*:*:*:*:*:*:*",
              "matchCriteriaId": "95ADB9E5-5309-4AB4-A3C5-B66287615C45",
              "vulnerable": true
            },
            {
              "criteria": "cpe:2.3:a:siemens:user_management_component:*:*:*:*:*:*:*:*",
              "matchCriteriaId": "14D9BFF6-39CC-40E3-A620-7100ADF9E814",
              "versionEndExcluding": "2.15.1.1",
              "vulnerable": true
            }
          ],
          "negate": false,
          "operator": "OR"
        }
      ]
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "A vulnerability has been identified in SIMATIC PCS neo V4.1 (All versions), SIMATIC PCS neo V5.0 (All versions), SINEC NMS (All versions \u003c V4.0), SINEMA Remote Connect (All versions), Totally Integrated Automation Portal (TIA Portal) V17 (All versions), Totally Integrated Automation Portal (TIA Portal) V18 (All versions), Totally Integrated Automation Portal (TIA Portal) V19 (All versions), Totally Integrated Automation Portal (TIA Portal) V20 (All versions), User Management Component (UMC) (All versions \u003c V2.15.1.1). Affected products contain a out of bound write buffer overflow vulnerability in the integrated UMC component. This could allow an unauthenticated remote attacker to cause a denial of service condition."
    },
    {
      "lang": "es",
      "value": "Se ha identificado una vulnerabilidad en SIMATIC PCS neo V4.1 (todas las versiones), SIMATIC PCS neo V5.0 (todas las versiones), SINEC NMS (todas las versiones), SINEMA Remote Connect (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V17 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V18 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V19 (todas las versiones), Totally Integrated Automation Portal (TIA Portal) V20 (todas las versiones) y User Management Component (UMC) (todas las versiones anteriores a la V2.15.1.1). Los productos afectados presentan una vulnerabilidad de desbordamiento del b\u00fafer de escritura fuera de los l\u00edmites en el componente UMC integrado. Esto podr\u00eda permitir que un atacante remoto no autenticado provoque una denegaci\u00f3n de servicio."
    }
  ],
  "id": "CVE-2025-30175",
  "lastModified": "2025-10-03T19:52:42.610",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "NETWORK",
          "availabilityImpact": "HIGH",
          "baseScore": 7.5,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "NONE",
          "integrityImpact": "NONE",
          "privilegesRequired": "NONE",
          "scope": "UNCHANGED",
          "userInteraction": "NONE",
          "vectorString": "CVSS:3.1/AV:N/AC:L/PR:N/UI:N/S:U/C:N/I:N/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 3.9,
        "impactScore": 3.6,
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ],
    "cvssMetricV40": [
      {
        "cvssData": {
          "Automatable": "NOT_DEFINED",
          "Recovery": "NOT_DEFINED",
          "Safety": "NOT_DEFINED",
          "attackComplexity": "LOW",
          "attackRequirements": "NONE",
          "attackVector": "NETWORK",
          "availabilityRequirement": "NOT_DEFINED",
          "baseScore": 8.7,
          "baseSeverity": "HIGH",
          "confidentialityRequirement": "NOT_DEFINED",
          "exploitMaturity": "NOT_DEFINED",
          "integrityRequirement": "NOT_DEFINED",
          "modifiedAttackComplexity": "NOT_DEFINED",
          "modifiedAttackRequirements": "NOT_DEFINED",
          "modifiedAttackVector": "NOT_DEFINED",
          "modifiedPrivilegesRequired": "NOT_DEFINED",
          "modifiedSubAvailabilityImpact": "NOT_DEFINED",
          "modifiedSubConfidentialityImpact": "NOT_DEFINED",
          "modifiedSubIntegrityImpact": "NOT_DEFINED",
          "modifiedUserInteraction": "NOT_DEFINED",
          "modifiedVulnAvailabilityImpact": "NOT_DEFINED",
          "modifiedVulnConfidentialityImpact": "NOT_DEFINED",
          "modifiedVulnIntegrityImpact": "NOT_DEFINED",
          "privilegesRequired": "NONE",
          "providerUrgency": "NOT_DEFINED",
          "subAvailabilityImpact": "NONE",
          "subConfidentialityImpact": "NONE",
          "subIntegrityImpact": "NONE",
          "userInteraction": "NONE",
          "valueDensity": "NOT_DEFINED",
          "vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:N/UI:N/VC:N/VI:N/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
          "version": "4.0",
          "vulnAvailabilityImpact": "HIGH",
          "vulnConfidentialityImpact": "NONE",
          "vulnIntegrityImpact": "NONE",
          "vulnerabilityResponseEffort": "NOT_DEFINED"
        },
        "source": "productcert@siemens.com",
        "type": "Secondary"
      }
    ]
  },
  "published": "2025-05-13T10:15:24.103",
  "references": [
    {
      "source": "productcert@siemens.com",
      "tags": [
        "Vendor Advisory"
      ],
      "url": "https://cert-portal.siemens.com/productcert/html/ssa-614723.html"
    }
  ],
  "sourceIdentifier": "productcert@siemens.com",
  "vulnStatus": "Analyzed",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-787"
        }
      ],
      "source": "productcert@siemens.com",
      "type": "Secondary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Sightings

Author Source Type Date

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.


Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…