FKIE_CVE-2025-36463

Vulnerability from fkie_nvd - Published: 2025-11-17 23:15 - Updated: 2026-06-17 09:14
Summary
Multiple out-of-bounds read and write vulnerabilities exist in the ControlVault WBDI Driver Broadcom Storage Adapter functionality of Dell ControlVault3 prior to 5.15.14.19 and Dell ControlVault3 Plus prior to 6.2.36.47. A specially crafted WinBioControlUnit call can lead to memory corruption. An attacker can issue an api call to trigger this vulnerability. This vulnerability is triggered when submitting a `WinBioControlUnit` call to the StorageAdapter with the ControlCode 4 (`WBIO_USH_ADD_RECORD`) and with an invalid `SendBufferSize`.
Impacted products
Vendor Product Version

{
  "affected": [
    {
      "affectedData": [
        {
          "defaultStatus": "unaffected",
          "product": "BCM5820X",
          "vendor": "Broadcom",
          "versions": [
            {
              "status": "affected",
              "version": "NA"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ControlVault3",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "5.15.14.19",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        },
        {
          "defaultStatus": "unaffected",
          "product": "ControlVault3 Plus",
          "vendor": "Dell",
          "versions": [
            {
              "lessThan": "6.2.36.47",
              "status": "affected",
              "version": "0",
              "versionType": "semver"
            }
          ]
        }
      ],
      "source": "talos-cna@cisco.com"
    }
  ],
  "cveTags": [],
  "descriptions": [
    {
      "lang": "en",
      "value": "Multiple out-of-bounds read and write vulnerabilities exist in the ControlVault WBDI Driver Broadcom Storage Adapter functionality of Dell ControlVault3 prior to 5.15.14.19 and Dell ControlVault3 Plus prior to 6.2.36.47. A specially crafted WinBioControlUnit call can lead to memory corruption. An attacker can issue an api call to trigger this vulnerability.\u00a0This vulnerability is triggered when submitting a `WinBioControlUnit` call to the StorageAdapter with the ControlCode 4 (`WBIO_USH_ADD_RECORD`) and with an invalid   `SendBufferSize`."
    }
  ],
  "id": "CVE-2025-36463",
  "lastModified": "2026-06-17T09:14:44.697",
  "metrics": {
    "cvssMetricV31": [
      {
        "cvssData": {
          "attackComplexity": "LOW",
          "attackVector": "LOCAL",
          "availabilityImpact": "HIGH",
          "baseScore": 7.3,
          "baseSeverity": "HIGH",
          "confidentialityImpact": "HIGH",
          "integrityImpact": "HIGH",
          "privilegesRequired": "LOW",
          "scope": "UNCHANGED",
          "userInteraction": "REQUIRED",
          "vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:R/S:U/C:H/I:H/A:H",
          "version": "3.1"
        },
        "exploitabilityScore": 1.3,
        "impactScore": 5.9,
        "source": "talos-cna@cisco.com",
        "type": "Secondary"
      }
    ],
    "ssvcV203": [
      {
        "source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
        "ssvcData": {
          "id": "CVE-2025-36463",
          "options": [
            {
              "exploitation": "none"
            },
            {
              "automatable": "no"
            },
            {
              "technicalImpact": "total"
            }
          ],
          "role": "CISA Coordinator",
          "timestamp": "2025-11-19T04:55:28.250024Z",
          "version": "2.0.3"
        }
      }
    ]
  },
  "published": "2025-11-17T23:15:53.687",
  "references": [
    {
      "source": "talos-cna@cisco.com",
      "url": "https://talosintelligence.com/vulnerability_reports/TALOS-2025-2175"
    },
    {
      "source": "talos-cna@cisco.com",
      "url": "https://www.dell.com/support/kbdoc/en-us/000326061/dsa-2025-228"
    }
  ],
  "sourceIdentifier": "talos-cna@cisco.com",
  "vulnStatus": "Deferred",
  "weaknesses": [
    {
      "description": [
        {
          "lang": "en",
          "value": "CWE-805"
        }
      ],
      "source": "talos-cna@cisco.com",
      "type": "Secondary"
    }
  ]
}


Log in or create an account to share your comment.




Tags
Taxonomy of the tags.


Loading…

Loading…

Loading…

Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.

Sightings

Author Source Type Date Other

Nomenclature

  • Seen: The vulnerability was mentioned, discussed, or observed by the user.
  • Confirmed: The vulnerability has been validated from an analyst's perspective.
  • Published Proof of Concept: A public proof of concept is available for this vulnerability.
  • Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
  • Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
  • Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
  • Not confirmed: The user expressed doubt about the validity of the vulnerability.
  • Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.

Loading…

Detection rules are retrieved from Rulezet.

Loading…

Loading…