FKIE_CVE-2025-52361
Vulnerability from fkie_nvd - Published: 2025-08-01 16:15 - Updated: 2025-11-03 20:19
Severity ?
Summary
Insecure permissions in the script /etc/init.d/lighttpd in AK-Nord USB-Server-LXL Firmware v0.0.16 Build 2023-03-13 allows a locally authenticated low-privilege user to execute arbitrary commands with root privilege via editing this script which is executed with root-privileges on any interaction and on every system boot.
References
Impacted products
| Vendor | Product | Version |
|---|
{
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Insecure permissions in the script /etc/init.d/lighttpd in AK-Nord USB-Server-LXL Firmware v0.0.16 Build 2023-03-13 allows a locally authenticated low-privilege user to execute arbitrary commands with root privilege via editing this script which is executed with root-privileges on any interaction and on every system boot."
},
{
"lang": "es",
"value": "Los permisos inseguros en el script /etc/init.d/lighttpd en el firmware v0.0.16 Build 2023-03-13 de AK-Nord USB-Server-LXL permiten que un usuario con privilegios bajos autenticado localmente ejecute comandos arbitrarios con privilegios de root mediante la edici\u00f3n de este script que se ejecuta con privilegios de root en cualquier interacci\u00f3n y en cada arranque del sistema."
}
],
"id": "CVE-2025-52361",
"lastModified": "2025-11-03T20:19:12.770",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "LOCAL",
"availabilityImpact": "HIGH",
"baseScore": 7.8,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "LOW",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:L/AC:L/PR:L/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.8,
"impactScore": 5.9,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2025-08-01T16:15:42.053",
"references": [
{
"source": "cve@mitre.org",
"url": "https://seclists.org/fulldisclosure/2025/Jul/20"
},
{
"source": "cve@mitre.org",
"url": "https://www.ak-nord.de/usbserver-usb--usb-converter--usb-auf-ethernet--usb-to-ethernet--usb-auf-lan--usb-server--usb-konverter--print-server-80.html"
},
{
"source": "af854a3a-2127-422b-91ae-364da2661108",
"url": "http://seclists.org/fulldisclosure/2025/Jul/20"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Awaiting Analysis",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-276"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…