FKIE_CVE-2025-67399
Vulnerability from fkie_nvd - Published: 2026-01-14 16:15 - Updated: 2026-02-12 17:54
Severity ?
Summary
An issue in AIRTH SMART HOME AQI MONITOR Bootloader v.1.005 allows a physically proximate attacker to obtain sensitive information via the UART port of the BK7231N controller (Wi-Fi and BLE module) on the device is open to access
References
| URL | Tags | ||
|---|---|---|---|
| cve@mitre.org | http://airth.com | Permissions Required | |
| cve@mitre.org | https://github.com/rupeshsurve04/CVE-2025-67399/blob/main/AIRTH_SMART_HOME_AQI_MONITOR_CVE-2025-67399.pdf | Third Party Advisory |
Impacted products
| Vendor | Product | Version | |
|---|---|---|---|
| airth | smart_home_aqi_monitor_bootloader | 1.005 |
{
"configurations": [
{
"nodes": [
{
"cpeMatch": [
{
"criteria": "cpe:2.3:a:airth:smart_home_aqi_monitor_bootloader:1.005:*:*:*:*:*:*:*",
"matchCriteriaId": "C9D00FAD-24F7-472F-AF47-009F0010BFA4",
"vulnerable": true
}
],
"negate": false,
"operator": "OR"
}
]
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "An issue in AIRTH SMART HOME AQI MONITOR Bootloader v.1.005 allows a physically proximate attacker to obtain sensitive information via the UART port of the BK7231N controller (Wi-Fi and BLE module) on the device is open to access"
}
],
"id": "CVE-2025-67399",
"lastModified": "2026-02-12T17:54:40.487",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "PHYSICAL",
"availabilityImpact": "NONE",
"baseScore": 4.6,
"baseSeverity": "MEDIUM",
"confidentialityImpact": "HIGH",
"integrityImpact": "NONE",
"privilegesRequired": "NONE",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:P/AC:L/PR:N/UI:N/S:U/C:H/I:N/A:N",
"version": "3.1"
},
"exploitabilityScore": 0.9,
"impactScore": 3.6,
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
},
"published": "2026-01-14T16:15:56.610",
"references": [
{
"source": "cve@mitre.org",
"tags": [
"Permissions Required"
],
"url": "http://airth.com"
},
{
"source": "cve@mitre.org",
"tags": [
"Third Party Advisory"
],
"url": "https://github.com/rupeshsurve04/CVE-2025-67399/blob/main/AIRTH_SMART_HOME_AQI_MONITOR_CVE-2025-67399.pdf"
}
],
"sourceIdentifier": "cve@mitre.org",
"vulnStatus": "Analyzed",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-200"
}
],
"source": "134c704f-9b21-4f2e-91b3-4a467353bcc0",
"type": "Secondary"
}
]
}
Loading…
Loading…
Sightings
| Author | Source | Type | Date |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
Loading…