FKIE_CVE-2026-71941
Vulnerability from fkie_nvd - Published: 2026-08-24 18:17 - Updated: 2026-08-26 17:08
Severity
Summary
Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the diag_logmail function. The vulnerability is caused by concatenating multiple smtpReceiver email addresses into a fixed-size buffer without checking the remaining buffer size. A remote attacker can trigger this vulnerability via crafted input, causing a denial of service or potentially executing arbitrary commands. Exploitation requires valid administrative credentials for the device's web management interface.
References
Impacted products
| Vendor | Product | Version |
|---|
{
"affected": [
{
"affectedData": [
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G2540xs",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "3.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2540xs",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "3.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch FX2120",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "3.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G2282x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.10.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2282x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.10.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch Q2300x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.10.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch PQ2300xb",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.10.7",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G2542x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "3.10.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2542x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "3.10.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2542xh",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "3.10.6",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch PX2060",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G1280",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P1280",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P1281x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G1282",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P1282",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G2121",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2121",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch PQ2121x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch Q2121x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G2280x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2280x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch Q2200x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch PQ2200xb",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G2100",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2100",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch G2540x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
},
{
"defaultStatus": "unaffected",
"product": "VigorSwitch P2540x",
"vendor": "DrayTek Corporation",
"versions": [
{
"lessThan": "2.9.10",
"status": "affected",
"version": "0",
"versionType": "custom"
}
]
}
],
"source": "disclosure@vulncheck.com"
}
],
"cveTags": [],
"descriptions": [
{
"lang": "en",
"value": "Multiple DrayTek VigorSwitch models contain a buffer overflow vulnerability in the diag_logmail function. The vulnerability is caused by concatenating multiple smtpReceiver email addresses into a fixed-size buffer without checking the remaining buffer size. A remote attacker can trigger this vulnerability via crafted input, causing a denial of service or potentially executing arbitrary commands. Exploitation requires valid administrative credentials for the device\u0027s web management interface."
}
],
"id": "CVE-2026-71941",
"lastModified": "2026-08-26T17:08:22.300",
"metrics": {
"cvssMetricV31": [
{
"cvssData": {
"attackComplexity": "LOW",
"attackVector": "NETWORK",
"availabilityImpact": "HIGH",
"baseScore": 7.2,
"baseSeverity": "HIGH",
"confidentialityImpact": "HIGH",
"integrityImpact": "HIGH",
"privilegesRequired": "HIGH",
"scope": "UNCHANGED",
"userInteraction": "NONE",
"vectorString": "CVSS:3.1/AV:N/AC:L/PR:H/UI:N/S:U/C:H/I:H/A:H",
"version": "3.1"
},
"exploitabilityScore": 1.2,
"impactScore": 5.9,
"source": "disclosure@vulncheck.com",
"type": "Primary"
}
],
"cvssMetricV40": [
{
"cvssData": {
"Automatable": "NOT_DEFINED",
"Recovery": "NOT_DEFINED",
"Safety": "NOT_DEFINED",
"attackComplexity": "LOW",
"attackRequirements": "NONE",
"attackVector": "NETWORK",
"availabilityRequirement": "NOT_DEFINED",
"baseScore": 8.6,
"baseSeverity": "HIGH",
"confidentialityRequirement": "NOT_DEFINED",
"exploitMaturity": "NOT_DEFINED",
"integrityRequirement": "NOT_DEFINED",
"modifiedAttackComplexity": "NOT_DEFINED",
"modifiedAttackRequirements": "NOT_DEFINED",
"modifiedAttackVector": "NOT_DEFINED",
"modifiedPrivilegesRequired": "NOT_DEFINED",
"modifiedSubAvailabilityImpact": "NOT_DEFINED",
"modifiedSubConfidentialityImpact": "NOT_DEFINED",
"modifiedSubIntegrityImpact": "NOT_DEFINED",
"modifiedUserInteraction": "NOT_DEFINED",
"modifiedVulnAvailabilityImpact": "NOT_DEFINED",
"modifiedVulnConfidentialityImpact": "NOT_DEFINED",
"modifiedVulnIntegrityImpact": "NOT_DEFINED",
"privilegesRequired": "HIGH",
"providerUrgency": "NOT_DEFINED",
"subAvailabilityImpact": "NONE",
"subConfidentialityImpact": "NONE",
"subIntegrityImpact": "NONE",
"userInteraction": "NONE",
"valueDensity": "NOT_DEFINED",
"vectorString": "CVSS:4.0/AV:N/AC:L/AT:N/PR:H/UI:N/VC:H/VI:H/VA:H/SC:N/SI:N/SA:N/E:X/CR:X/IR:X/AR:X/MAV:X/MAC:X/MAT:X/MPR:X/MUI:X/MVC:X/MVI:X/MVA:X/MSC:X/MSI:X/MSA:X/S:X/AU:X/R:X/V:X/RE:X/U:X",
"version": "4.0",
"vulnAvailabilityImpact": "HIGH",
"vulnConfidentialityImpact": "HIGH",
"vulnIntegrityImpact": "HIGH",
"vulnerabilityResponseEffort": "NOT_DEFINED"
},
"source": "disclosure@vulncheck.com",
"type": "Secondary"
}
]
},
"published": "2026-08-24T18:17:19.680",
"references": [
{
"source": "disclosure@vulncheck.com",
"url": "https://www.draytek.com/about/security-advisory/multiple-vulnerabilities-in-vigorswitch-series-august-2026/"
},
{
"source": "disclosure@vulncheck.com",
"url": "https://www.vulncheck.com/advisories/draytek-vigorswitch-multiple-models-buffer-overflow-via-diag-logmail"
}
],
"sourceIdentifier": "disclosure@vulncheck.com",
"vulnStatus": "Deferred",
"weaknesses": [
{
"description": [
{
"lang": "en",
"value": "CWE-120"
}
],
"source": "disclosure@vulncheck.com",
"type": "Primary"
}
]
}
Loading…
Loading…
Experimental. This forecast is provided for visualization only and may change without notice. Do not use it for operational decisions.
Forecast uses a logistic model when the trend is rising, or an exponential decay model when the trend is falling. Fitted via linearized least squares.
Sightings
| Author | Source | Type | Date | Other |
|---|
Nomenclature
- Seen: The vulnerability was mentioned, discussed, or observed by the user.
- Confirmed: The vulnerability has been validated from an analyst's perspective.
- Published Proof of Concept: A public proof of concept is available for this vulnerability.
- Exploited: The vulnerability was observed as exploited by the user who reported the sighting.
- Patched: The vulnerability was observed as successfully patched by the user who reported the sighting.
- Not exploited: The vulnerability was not observed as exploited by the user who reported the sighting.
- Not confirmed: The user expressed doubt about the validity of the vulnerability.
- Not patched: The vulnerability was not observed as successfully patched by the user who reported the sighting.
Loading…
The MITRE ATT&CK techniques below are AI-generated suggestions, inferred from the description of the
vulnerability by the CIRCL/vulnerability-attack-technique-classification-roberta-base
model, served locally by ML-Gateway.
They have not been verified by an analyst and are provided for guidance only.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
The approach is described in our paper Mapping CVEs to MITRE ATT&CK Techniques: A Curated Gold-Set Classifier and the Limits of LLM-Assisted Label Expansion.
Loading…
Loading…